Limiting-current type Oxygen Analyzer OX100, OX102 OX100, OX102 Limiting-current type Oxygen Analyzer • One Instrument measures 100 ppm to 25% Oxygen • Simple "One Touch" Calibration • Self Diagnostics Assure High Reliability • "One Touch" Sensor Replacement • Compact Size • Accessories to Assure Accuracy • Dedicated Sampling Unit (Separate from Oxygen Analyzer) (Removes Dust, Mist and Organic Solvents) • Calibration Kit Simple On-Site Calibration (Using 1 liter Gas Cylinder)

Abrir o catálogo na página 1
OX100, OX102 Current Limit Type Oxygen Analyzers - 2

A Compact Environmental Oxygen Anal] Enhanced Oxygen Analyzer • Autoranging in four ranges from 0-100 ppm to 0-25% 1N2 reflow furnaces ■Semiconductor maker environmental monitoring ■ppm-level O2 measurement ■ Monitoring purity of N2, Ar separated from air ■ Monitoring for deficiency of O2 •FAIL lamp Alarm lamps (Calibration keys I— ©Lit when range parameter entry • Plastic sensor holder (Specify Option code /J (Sensor plus cable: *5 m (OX100), *5,10 or 30 m (OX102) 1 : When mount in 17 mm hole in panel, panel thickness can be up to 4 mm. 2 : Within 5 cm of sensor tip, can reach 250°C. 3 :...

Abrir o catálogo na página 2
OX100, OX102 Current Limit Type Oxygen Analyzers - 3

Panel thickness * : Allow the minimum clearance of Min. space for multiple installation : A Ma* temp. 1 StFC when metal nipple {option code 73* or P/W K9424DB) is used. Extension cable Sensor Assembly

Abrir o catálogo na página 3
OX100, OX102 Current Limit Type Oxygen Analyzers - 4

OX102 EXTERNAL DIMENSIONS Convertor Other instrument * : Allow a minimum distance of 115mm for ease of removal. Min. space for multiple installation Sensor parameter Table Sensor NO. XXXX Temp. 150ЊC Max. Temp. 250ЊC Max. ‫ ء‬Max temp. 70ЊC when plastic nipple (option code "/J" or P/N L9811LA) is used. Sensor External Dimension Model Code

Abrir o catálogo na página 4
OX100, OX102 Current Limit Type Oxygen Analyzers - 5

Pressure meter (flow adjustment) Sampling unit (K9424GA) Power supply 1 Activated charcoal, membrane filter Flow meter 1000 ppm O2/N2 Quantity 6, one-liter Calibration gas cylinder (K9424JP) Needle valve Membrane filter: removes dust / mist / flux Activated charcoal, membrane filter: remove organic solvents Flow meter: 0.1 to 1 liters / min. Operating conditions: Atmospheric pressure, gas temperature 0 to 40°C Mounting Rc 1/4 Power 100-240 V AC Calibration kit (K9424JA, JB) Gas outlet cock + Qty. 6, one Calibration gas cylinder 210 x 75 x 335 mm, approx 800 g. Power line connector Sample...

Abrir o catálogo na página 5
OX100, OX102 Current Limit Type Oxygen Analyzers - 6

OX102 Standard Specifications Model Meas. principle Sampling Sample gas condition Measured gas Mounting Meas. ranges Repeatability Limiting-current type Natural diffusion Temperature 0 - 70°C, Humidity 0 - 80% RH (dew free), Pressure 1013 ± 40 hPa (Abs) O2 in N2 or mixed gases; cannot be used with silicone vapor, combustible gases or organic solvents Indoor, panel mounting 0-100 ppm / 0-1000 ppm / 0-10000 ppm / 0-25%, automatic / fixed switching mode ±15 ppm (Meas. range : 20-100 ppm), ±25 ppm (Meas. range : 100-1000 ppm), ±0.3%of reading (Meas. range : 1000-5000 ppm), ±7.5% of reading...

Abrir o catálogo na página 6
OX100, OX102 Current Limit Type Oxygen Analyzers - 7

I 0X102 Limiting-current type Oxygen Analyzer VigilantPlant is Yokogawa's automation concept for safe, reliable, and profitable plant operations. VigilantPlant aims to enable an ongoing state of Operational Excellence where plant personnel are watchful and attentive, well-informed, and ready to take actions that optimize plant and business performance. YOKOGAWA ELECTRIC CORPORATION World Headquarters North America YOKOGAWA CORPORATION OF AMERICA South America YOKOGAWA AMERICA DO SUL LTDA. European Headquarters RUSSIAN FEDERATION Middle East YOKOGAWA MIDDLE EAST B.S.C.(C) YOKOGAWA...

Abrir o catálogo na página 7

Todos os catálogos e folhetos técnicos YOKOGAWA Europe

  1. YS1500

    20 Páginas

  2. UM33A/S006

    2 Páginas

  3. YTA610

    20 Páginas

  4. FA-M3V

    19 Páginas

  5. RAMC

    24 Páginas

  6. TB750G EXAxt

    3 Páginas

  7. JUXTA VJ series

    7 Páginas

  8. µR10000/µR20000

    8 Páginas

  9. OX400

    2 Páginas

  10. MW100

    5 Páginas

  11. FieldMate

    5 Páginas

  12. AMADAS

    4 Páginas

  13. Exapilot

    5 Páginas

  14. Exaquantum

    5 Páginas

  15. BUCA150_E_050

    4 Páginas

  16. BUAQ7280-01

    12 Páginas

  17. BUXL120_E_030

    8 Páginas

  18. BU7603_00E_060

    20 Páginas

  19. BUAQ2200

    8 Páginas

  20. Batch Control

    9 Páginas

  21. RAGN Rotameter

    2 Páginas

  22. Catalog_YMI130_EN

    86 Páginas

  23. FY01A08A08-E-E

    2 Páginas

  24. ADMAG Series

    9 Páginas

  25. Exaplog

    2 Páginas

  26. AAASuite

    2 Páginas

  27. InfoWell

    8 Páginas

  28. Standalone SIS

    3 Páginas

  29. VTSPortal

    2 Páginas

  30. GS01E06K02-00E

    2 Páginas

  31. U33Q01A01-01E

    11 Páginas

  32. BU33K01A01-50E

    11 Páginas

  33. Clamp-on Testers

    12 Páginas

  34. Handy Calibrators

    4 Páginas

  35. CENTUM.VP

    11 Páginas

  36. ADMAG AXF

    2 Páginas

  37. YTA series

    7 Páginas

Catálogos arquivados