Feeder/MotorProtection Relay VAMP 40 >
Abrir o catálogo na página 1
? Complete Protection Comprehensive selection of protection functionsfor distribution network overhead line feeders, cable feeders, motor feeders including large motors, capacitor banks and reactors. ? Comprehensive Measurements Wide range of measurement functions including phase and residual currents, residual or line or phase voltage, frequency, current unbalance, maximum demand, negative phase sequence current, active and reactive power and energy according to the primary connection. ? Power Quality Assessment Power quality assessment and analysis including supervision of harmonics up to...
Abrir o catálogo na página 2
Traditional protection relay systemsdo not provide fast enoughprotection in an arc-fault situations.The VAMP 40 protection relay withintegrated arc protection alsoprovide a cost efficient high-speedMV busbar protection. The motor start-up register stores the motor start-up values(start current, duration etc.) significantly facilitating the correct setting of the relay even if critical motor data are unavailable from the manufacturer. > As a regularfeature of theVAMP relays standard COMTRADE type disturbancerecording files canbe uploaded for subsequent evaluation of anynetwork eventrecorded....
Abrir o catálogo na página 4
Order Code DescriptionNote VAMP 40 Feeder / motor protection relay VAMP Ltd > VEA3CG Ethernet Interface Module > VPA3CG Profibus Interface Module VSE001 Fiber optic Interface Module VSE002 RS485 Interface Module VSE004 VAMP 40 RS-485 module VSE005-1 Ethernet and RS-485 module VX003-3 Programming Cable (VAMPSET) Cable length 3 m VX028-3 Interface cable to VPA3CG ( Profibus adaptor)Cable length 3 m VX030-3 Interface cable to VEA3CG (Ethernet adaptor) Cable length 3 m VX032-3 Rear panel programming cableCable length 3 m VYX256A Optional seal for IP54 VP40 Arc option VA1DA-6 Arc SensorCable...
Abrir o catálogo na página 6
Rated current In 5 A (configurable for CT secondaries 1 10 A) Dimensions (W x H x D)280 x 195 x 55 mm - Current measuring range0օ250 A- Thermal withstand20 A (continuously)100 A (for 10 s) 500 A (for 1 s)- Burden< 0.2 VA Degree of protection IP 54 Weight 3 kg (terminal, package and manual) > Rated current Ion 1/5 A- Current measuring range050 A / 10 A Emission EN 61000-6-4 / IEC 60255-26- Conducted EN55011 / IEC 60255-25 0.15 - 30 MHz - EmittedEN55011 / IEC 60255-25 30 - 1000 MHz Immunity EN 61000-6-2 / IEC 60255-26- Static discharge (ESD) EN 61000-4-2 class IV / IEC 60255-22-28 kV contact...
Abrir o catálogo na página 7
Vamp LtdP.O.Box 810 FI-65101 VAASA FinlandVisiting address:Vaasa Airport Park Yrittjnkatu 15 Vaasa, Finland Tel: +358 20 753 3200Fax: +358 20 753 3205 Email: vamp@vamp.fi http:// www.vamp.fi > We reserve the rights to product alterations without prior notice.Copyright 䤩 Vamp Ltd. All trademarks are the property of theirrespective holders. VB40.EN004 size="-2">
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos Vamp
-
vamp 265
2 Páginas
-
VAMP 11V
16 Páginas
-
VAMP 1 1 F
16 Páginas
-
VAMP 50 series
20 Páginas
-
VAMP 96 and VAMP 260
12 Páginas
-
VAMP 57
16 Páginas
-
VAMP 259
12 Páginas
-
VAMP 230, VAMP 255 and VAMP 257
16 Páginas
-
VAMP 125
1 Páginas
-
VAMP 125 Unit for flexible
12 Páginas
-
VAMP 120 & 121
8 Páginas
-
VAMP 11V
16 Páginas
-
VAMP 321
12 Páginas
-
VAMP 59
12 Páginas
-
VAMP 55
190 Páginas
-
VAMP 120
8 Páginas
-
VAMP 40
24 Páginas
-
VAMP 50
20 Páginas
-
VAMP 230
16 Páginas
-
VAMP 210
2 Páginas
-
VAMP 135
8 Páginas
Catálogos arquivados
-
VAMP 221_2013
16 Páginas
-
VAMP 221_2011
16 Páginas
-
VAMP 96
16 Páginas
-
ARC Protection
20 Páginas
-
Customer
28 Páginas
-
Vamp Arc Protection Series
16 Páginas
-
Vamp Feeder/Motor Manager
16 Páginas
-
Selection table
1 Páginas
-
Vamp Protection Relays
16 Páginas