LK-series (oil-air coolers) industrial or mobile - 1

advanced quality customized designs made in europe Oil/Air heat exchangers OIL-AIR COOLING I Low noise level I High performance I Low cost The cut-away perspective shows the housing with thick steel walls aun high-performance cooling chamber incorporating copper pipes and aluminium cooling ribs.

Abrir o catálogo na página 1
LK-series (oil-air coolers) industrial or mobile - 2

Product description Product description With this new generation of Universal Hydraulik LKI oil-coolers, the manufacturers have succeeded in reducing the noise level. These coolers are ideally suited for stationary installations - for the cooling of hydraulic or lubricating oils. The range has been extended to include slowrunning ventilators, and the housings have been optimised, in order to produce the very low noise level. In order to make the cooler range as comprehensive as possible, the smaller models are also available as single or dual versions, thus covering oil-cooling requirements...

Abrir o catálogo na página 2
LK-series (oil-air coolers) industrial or mobile - 3

Your Partner for coolers and systems Flow Rate The calculation of the specific cooling performance is based on an oil temperature of 140° F, an ambient temperature of 68° F - and there- fore a temperature difference of 72° F. The figures apply to ISO VG32 hydraulic oil with 30 cSt. For variances, Ap is multiplied by the correc- tion factor f from the diagram on Page 3.

Abrir o catálogo na página 3
LK-series (oil-air coolers) industrial or mobile - 4

Lifting and transport points 9,65 Motor 0,5HP; 2-pol Nema Frame Size 56C 9,65 Motor 0,33HP; 4-pol Nema Frame Size 56C LKI 100 - 600: lateral internal-thread oil connections Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 4
LK-series (oil-air coolers) industrial or mobile - 5

LKI-300/400 Dimensions Lifting and transport points 9,65 Motor 0,5HP; 4-pol Nema Frame Size 56C 9,65 Motor 0,5HP; 6-pol Nema Frame Size 56C LKI 100 - 600: lateral internal-thread oil connections Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 5
LK-series (oil-air coolers) industrial or mobile - 6

LKI-500/600 Dimensions Lifting and transport points 11,5 Motor 1HP; 4-pol Nema Frame Size 143TC 9,65 Motor 0,5HP; 6-pol Nema Frame Size 56C LKI 100 - 600: lateral internal-thread oil connections Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 6
LK-series (oil-air coolers) industrial or mobile - 7

LKI-700 Dimensions Lifting and transport points 35,43 31,89 29,92 14,1 Motor 1,5HP; 6-pol Nema Frame Size 182TC 13,14 Motor 1HP; 8-pol Nema Frame Size 182T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 7
LK-series (oil-air coolers) industrial or mobile - 8

LKI-800 Dimensions Lifting and transport points 39,37 35,83 33,86 13,5 Motor 2HP; 6-pol Nema Frame Size 184TC 13,14 Motor 1HP; 8-pol Nema Frame Size 182T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 8
LK-series (oil-air coolers) industrial or mobile - 9

LKI-900 Dimensions Lifting and transport points 43,31 39,76 37,80 16,2 Motor 5HP; 6-pol Nema Frame Size 215TC 14,31 Motor 2HP; 8-pol Nema Frame Size 213T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 9
LK-series (oil-air coolers) industrial or mobile - 10

LKI-1000 Dimensions Lifting and transport points 47,24 43,70 41,73 16,2 Motor 5HP; 6-pol Nema Frame Size 215TC 14,31 Motor 2HP; 8-pol Nema Frame Size 213T LKI 700 - 1000: lateral internal-thread oil connections and SAE flange at front or rear Technical data Model Motor performance Power consumption Noise level* * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 10
LK-series (oil-air coolers) industrial or mobile - 11

Hydraulic Motor Information Model Motor performance * may vary by ±3 dB(A) due to room characteristics, own frequencies, oil connections, viscosities etc.

Abrir o catálogo na página 11
LK-series (oil-air coolers) industrial or mobile - 12

advanced quality customized designs Ordering code UNIVERSAL • ijijiiji Your Partner for coolers and systems Cooler with hydraulic motor = LKHYD Unit Size flat version, with mounting Cooling block Cooling block Motor type Motors with special voltages, hydraulic and explosion protection available on request. All motors comply with EISA regulations. The technical data of this sheet is depending on the described operational conditions and individual cases. At different operational conditions and differing individual cases contact UniversalHydraulik. Technical modifications reserved. Please also...

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos Universal Hydraulik GmbH

  1. LKM

    1 Páginas

  2. LKI/LKI-HYD

    13 Páginas

  3. UHD 160

    12 Páginas

  4. SSP/ HSSP

    7 Páginas

  5. UKC-G

    2 Páginas

  6. CKM/FS

    2 Páginas

  7. EK/SC UK/UKT

    10 Páginas

  8. EKM/SKM

    12 Páginas

  9. SCM

    7 Páginas

  10. COOLING SYSTEMS

    2 Páginas

  11. TFS/A

    4 Páginas

  12. EK/SC

    10 Páginas

  13. LKFM

    1 Páginas

  14. Serie SCM/FS

    2 Páginas

  15. Serie SCM

    7 Páginas

  16. Serie UKCG

    2 Páginas

  17. SSP series

    4 Páginas

  18. Serie WRV

    2 Páginas

  19. Serie UKTM

    8 Páginas

  20. CK-series

    4 Páginas

  21. Serie UKM

    8 Páginas

  22. Serie CKMFS

    2 Páginas

  23. Serie TL

    4 Páginas

  24. Serie TFSA

    4 Páginas

  25. Serie PWT

    2 Páginas

  26. Serie LKM

    12 Páginas

  27. Serie LKI

    12 Páginas

  28. Serie LKI-HYD

    8 Páginas

  29. Serie EKM/SKM

    10 Páginas

  30. Serie EDH

    8 Páginas

  31. Serie ECM

    8 Páginas

  32. Serie CKM

    8 Páginas

  33. PTÖK series

    6 Páginas

Catálogos arquivados

  1. Serie AM

    8 Páginas