Excertos do catálogo

Impulse diffusers Type ISH Cooling mode, horizon tal air discharge For industrial zones without air polluting processes Impulse diffusers with horizontal air discharge in cooling mode ■■ Nominal sizes 250, 355, 450, 560 mm ■■ Volume flow rate range 205 – 1585 l/s or 738 – 5706 m³/h ■■ Casing made of galvanised sheet steel ■■ For variable and constant volume flows ■■ Installation either free hanging or on walls or pillars ■■ Large throw distance due to high discharge momentum ■■ Discharge direction can be adjusted manually or with an actuator Heating mode, vertical air discharge ■■ Chain pull for adjusting the discharge direction manually Optional equipment and accessories ■■ Exposed diffuser parts in RAL CLASSIC colours ■■ Electric and thermal actuators for adjusting the air discharge direction ■■ Bowden cable for adjusting the discharge direction manually ■■ Wall mount
Abrir o catálogo na página 1
Impulse diffusers General information Page General information Function Technical data Quick sizing Specification text Order code Accessories Dimensions and weight Installation details Basic information and nomenclature Application – Type ISH impulse diffusers are used primarily for industrial zones without air polluting work processes – Horizontal air discharge in cooling mode, vertical air discharge in heating mode – Ventilation of large occupied zones due to high discharge momentum – For variable and constant volume flows – For supply air to room air temperature differences...
Abrir o catálogo na página 2
Impulse diffusers ISH Functional description Impulse diffusers discharge the air from air conditioning systems with a high momentum such that large throw distances are achieved. This allows for the ventilation of large areas. Type ISH impulse diffusers are used primarily for industrial zones without air polluting work processes. They are installed above the occupied zone. An adjustable air control disc allows for adapting the air discharge direction to heating or cooling mode. The supply air to room air temperature difference may range from –8 to +12 K. Cooling mode In...
Abrir o catálogo na página 3
Impulse diffusers
Abrir o catálogo na página 4
Impulse diffusers Technical data Nominal sizes Minimum volume flow rate Maximum volume flow rate, with LWA ≅ 55 dB(A) Supply air to room air temperature difference
Abrir o catálogo na página 5
Impulse diffusers Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures. The maximum volume flow rates apply to a sound power level of approx. 55 dB (A).
Abrir o catálogo na página 6
Impulse diffusers Specification text This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme. Impulse diffusers with a cylindrical casing, for industrial zones without air polluting work processes. With adjustable air control disc for air patterns from horizontal (0°) to vertical (90°). Large throw distances with horizontal air discharge. For free hanging installation and also for installation on walls or pillars. Ready-to-install component which consists of a cylindrical...
Abrir o catálogo na página 7
Impulse diffusers HI Type ISH Impulse diffuser [2] Actuator No entry: chain pull for manual adjustment B Bowden cable for manual adjustment E6 24 V AC/DC, modulating 0 - 10 V DC T Thermal actuator [4] Fixing No entry: none W00 With wall mount K00 With chain fixing (only for variants with chain pull) WK0 With wall mount and chain fixing (only for variants with chain pull) [5] Exposed surface No entry: galvanised P0 Powder-coated RAL 9010, pure white P1 Powder-coated, specify RAL CLASSIC colour Gloss level RAL 9010 50 % RAL 9006 30 % All other RAL colours 70 % 24 V AC/DC,...
Abrir o catálogo na página 8
Impulse diffusers ISH Wall mount (accessory) a ① Diffuser ② Centre of diffuser ③ Wall mount, inner part ④ Wall mount, outer part ⑤ Wall bracket
Abrir o catálogo na página 9
Impulse diffusers Chain pull for manual adjustment Bowden cable for manual adjustment
Abrir o catálogo na página 10
Impulse diffusers Dimensions and weight ISH-E* Electric actuator 02/2017 - DE/en TROX ®TECHNIK
Abrir o catálogo na página 11
Impulse diffusers Installation details Installation and commissioning – Installation preferably at heights between 3.5 m and 10 m – Freely suspended installation – Vertical duct connection – The spigot has to be screw-fixed to the duct and the entire system has to be securely fixed and suspended (by others) – Fixing to walls or pillars with optional wall mount – Attach the chain fixing and the hand lever of he t Bowden cable to the wall or pillar, if necessary These are only schematic diagrams to illustrate installation details. Free hanging installation above workstations –...
Abrir o catálogo na página 12
Impulse diffusers Installation details Free hanging installation Wall fixing ① Wall mount
Abrir o catálogo na página 13
Impulse diffusers Installation details Wall fixing, detail ① Screws to be fixed once the diffuser has been placed
Abrir o catálogo na página 14
Impulse diffusers Basic information and nomenclature Hauptabmessungen B₁ [mm] Breite des Frontdurchlasses B₄ [mm] Breite eines rechteckigen Anschlussstutzens ØD [mm] Außendurchmesser des Anschlussstutzens ØD₁ [mm] Gehäusedurchmesser Definitionen LWA [dB(A)] Schallleistungspegel des Strömungsgeräusches, A-bewertet ISH H₁ [mm] Höhe des Frontdurchlasses T₁ [mm] Gehäusetiefe T₄ [mm] Tiefe eines rechteckigen Anschlussstutzens m [kg] Gewicht (Masse) Nahzone mindestens 0,5 m Im Abstand Lnz beträgt die Luftgeschwindigkeit maximal 0,2 m/s, gemessen 0,1 m über dem Boden [m³/h] und [l/s]...
Abrir o catálogo na página 15Todos os catálogos e folhetos técnicos TROX
-
Type KA-EU
21 Páginas
-
Type FK-EU
52 Páginas
-
Type XSA
21 Páginas
-
Type MSA
21 Páginas
-
Type DLQ
20 Páginas
-
Type DCS
24 Páginas
-
Type FD
22 Páginas
-
Swirl Diffuser VDW
2 Páginas
-
Air terminal devices
4 Páginas
-
DID642
22 Páginas
-
DID632
25 Páginas
-
DID300B
24 Páginas
-
DID312
22 Páginas
-
DID614
17 Páginas
-
Control_units
626 Páginas
-
Type FD
35 Páginas
-
Ceiling swirl diffusers Type FD
22 Páginas
-
JZ-HL
19 Páginas
-
JZ-LL
23 Páginas
-
JZ-HL-AL
16 Páginas
-
JZ-AL
15 Páginas
-
JZ-LL-AL
16 Páginas
-
Displacement Flow Diffusers
32 Páginas
-
Air-water systems Design manual
60 Páginas
-
Volume Flow Limiter
6 Páginas
-
High Efficiency Terminal Filters
12 Páginas
-
High efficiency air filter
9 Páginas
-
Volume Flow Controller
12 Páginas
-
Rectangular fire damper
16 Páginas
-
Smoke Detector
7 Páginas
-
Filter Media
16 Páginas
-
Bag Filter Inserts
5 Páginas
-
Volume Flow Controller
12 Páginas
-
Jet nozzles
12 Páginas