GSM8-80 Range Motor Protection Circuit Breakers GSM8-80 range motor protection circuit breakers are mainly used in the electrical circuits with AC frequency 50Hz/60Hz, rated voltage up to 415V and rated current up to 25A~ 80A to conduct the protection functions of the over-load, short-circuit, non-frequent start-up and while-running breaking for the three-phase motors, also can be used as isolators. CONFORM STANDS AND CERTIFICATION_ This product complies with the demands of the following standards: A fcEHftig^GB 14048.2 Effiff ^SSfflSfffiSS GB14048.2 Low-voltage Switch gear and control gear low-voltage GB14048.3 low-voltage switchgear and control gear SwitchgearN solationx Separated Switch And Fuse Combination Apparatus Low-voltage mechanical breaker and motor starterGBI 4048.4 Low- voltage switchgear and control gear A HHCCCiAiIE Through the CCC certification E, M^&Me&$L TYPE AND MEANS Humid tropics of the product, code-named "TH lff)i;§ (H!§4) Annex code (see table 4] Current code requirements (see table 1 ] Rated current level of aircraft shel SttlS^ij Design serial number liinijCi^li§§§lvloulded case circuit breakers tT^I l/ffi^l Enterprises code WORKING CONDITION AND INSTALLATION CONDITION A llSn,ill: -5°C~ +40°Co Environment temperature :-5°C~+40°C Environment condition: There must be not any explosive medium and there
Abrir o catálogo na página 1
mustbenotanygaswhich would corrode metal or any conducting dust which would destroy the insulation. A Sli^gO: SlS^gy III o Installing categories: Class III. A Si^mj: S^^S?33o Pollution protection: Grade 3 I jSJjtzSPr: Installation condition The tilt gradient between installation face and vertical face should ^30° nstalling condition: mounted byTH35-7.5 standard rail track. Products should be used in no significant impact and vibration place. 2L MAIN TECHNICAL PARAMETERS ■ li^K^ill&flflSS'l) Basic technical parameters(as table 1)
Abrir o catálogo na página 2
■ feii§^|fTSb^](flllS3) short-circuit breaking capacity(as table 3)
Abrir o catálogo na página 3
OUTLINE AND MOUNTING DIMENSIONS (as picture 2) Picture 2 outline and mounting dimensions breaker mainly wiring picture (as picture 3) Picture 3 breaker mainly wiring picture
Abrir o catálogo na página 4
Circuit breakers should be installed vertically and check in before the nstallation of circuit breakers nameplate on the technical parameters set out in compliance with the requirements to use. Electricity before manual circuit breaker on several occasions, the agency action should be flexible and reliable, non-blocking phenomenon. A STB^&ffi (US) , ^KRhTSlfi^S; &T«imm (IIS) , EfeSSRh Press the button closure (black), the circuit is connected to the state; press the disconnect button (red), in a disconnected state circuit. stfc&T, iiaisft c^mmmn^ "Test" mm), mmmm^mm^. The use of the...
Abrir o catálogo na página 5Todos os catálogos e folhetos técnicos Tianshui 213 Electrical Apparatus Group CO.
-
GSC2-F Range AC Contactor
5 Páginas
-
CIRCUIT BREAKERS GSB1Z
3 Páginas
-
GSW1
33 Páginas
-
GSC1-4011 FC-6511 FC
4 Páginas
-
GSC3 series
5 Páginas
-
GSB2
4 Páginas
-
GSA1 Series
15 Páginas
-
GSB2-32N Mini circuit breaker
3 Páginas
-
GSB2-32N
3 Páginas
-
GSG2 insolated switch
14 Páginas
-
GSB1Z-40 DC Mini circuit breaker
4 Páginas
-
JZC3-dZ DC Contactor relay
3 Páginas
-
GSR3 Electrical overload relay
4 Páginas
-
GSC11-4008~9508 4 pole contactor
4 Páginas
-
JZC3 Contactor relay
4 Páginas
-
JRS4-F thermal overload relay
5 Páginas
-
CJX4-kd capacity contactor
5 Páginas
-
molded case circuit breaker
26 Páginas
-
GSG1 -100 series Disconnect switch
3 Páginas
-
GSU1 series surge protection device
5 Páginas
-
JRS4-d series thermal overload relay
8 Páginas
-
3P AC contactor GSC1
7 Páginas