CITA
1 / 4Páginas

{{requestButtons}}

Excertos do catálogo

CITA - 1

(metallic enclosure - aluminium) 1P up to 4P Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000 m. Maximum humidity: 90%. Pollution degree: 3 (standard for industrial applications). ated frecuency at AC utilization categories: 50/60 Hz. R R ated duties at utilization categories AC21A, AC22A and AC23A: Continuing (8 hours); uninterrupted. (in & out by cable gland - not included) AC rated operational current Rated thermal current Rated insulation voltage Rated impulse withstand voltage

Abrir o catálogo na página 1
CITA - 2

Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000 m. Maximum humidity: 90%. Pollution degree: 3 (standard for industrial applications). ated frecuency at AC utilization categories: 50/60 Hz. R R ated duties at utilization categories AC21A, AC22A and AC23A: Continuing (8 hours); uninterrupted. Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical...

Abrir o catálogo na página 2
CITA - 3

CITA CITC Arrow handle Chambers Padlockable handle *(1) With terminals for connection *(2) Mounting without connection terminals or terminals + phase barriers Normal service conditions: Ambient air temperature (ºC): -5º...+40º. Maximum altitude: 2.000 m. Maximum humidity: 90%. Pollution degree: 3 (standard for industrial applications). ated frecuency at AC utilization categories: 50/60 Hz. R R ated duties at utilization categories AC21A, AC22A and AC23A: Continuing (8 hours); uninterrupted. (in & out by cable gland - not included) Rated conditional short-circuit current Rated maximum...

Abrir o catálogo na página 3
CITA - 4

(metallic enclosure - cast iron with door) 1P up to 4P Arrow handle Chambers Padlockable handle Technical information According to IEC 60947-3 AC rated operational current Rated conditional short-circuit current Rated maximum current gL-gG Rated breaking capacity 400V; cos φ=0,45 Rated short-time withstand current (1 sec) Mechanical durability (according to the standards, for other values please consult) Rigid copper conductor Flexible copper conductor Rated thermal current Rated insulation voltage Rated impulse withstand voltage Normal service conditions: Ambient air temperature (ºC):...

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos Telergon

  1. ATS

    8 Páginas

  2. S5M DC

    3 Páginas

  3. S6R DC

    2 Páginas

  4. S6N DC

    2 Páginas

  5. S6 DC

    4 Páginas

  6. S5 DC

    5 Páginas

  7. CIF22

    2 Páginas

  8. M21 M21 series

    3 Páginas

  9. series CTR

    7 Páginas

  10. CCF CCP

    3 Páginas

  11. S5F

    6 Páginas

  12. CEC series

    2 Páginas

  13. S6N AC

    2 Páginas

  14. S5M AC

    4 Páginas

  15. S6 AC

    2 Páginas

  16. S5 AC

    9 Páginas

  17. ZBK

    4 Páginas

  18. CITP CTFR

    3 Páginas

  19. TP T TB TF

    8 Páginas

  20. Cam switches

    17 Páginas