Excertos do catálogo

Sierra™ M6-1 SAS and SATA Protocol Test System S Protocol Solutions Group Product Datasheet P d tD t h t 6 Gb/s Flexible, Portable and Affordable! Key Features The Sierra M6-1 prod ducts are ultra-portable single-port systems with models available that function as a protocol analyzer or as an error injector. Measuring just n 6.25” wide, 1.38” high and 9.0” deep (15.9 x 3.5 x 22.9 cm) and weighing in at h 1.7 lbs (0.77 Kg), Sie M6-1 systems are incredibly compact units that fit easily erra into a corner of a brie efcase or backpack. Capable of operating at 1.5, 3 or 6 Gb/s data rates and equipp with up to 4 GB of recording memory, the Sierra M6-1 ped offers world-class pro otocol analysis or error injection capability at price points within reach of every budge et. ■ 6 Gb/s SAS/SATA protocol analysis or error injection ■ Native PHY for fast lock time ■ Easy mode triggering ■ Cascade capability, up to 8 ports ■ Sync with other LeCroy Sierra™ and STX family products ■ Hardware filtering ■ Automatic error detection ■ Comprehensive decoding of SAS and SATA data traffic ■ Logical and chronological traffic displays Sierra M6-1 systems come standard with both USB and GbE interface ports for maximum flexibility in connecting to the PC which serves as the host for analysis or n error injection software. The versatile GbE port can be used for either local or remote network conn nectivity. Sierra M6-1 systems can be linked together in cascaded configuratio to provide additional recording channel capacity or used in ons capacity, tandem to combine s simultaneous error injection and trace capture/analysis capabilities (requires multiple Sierra M6-1 units, at least one licensed as a protocol analyzer model and o licensed as an error injector model). one ■ Statistical reporting Expert Analysis Sof ftware ■ Trace memory of 2 or 4 GB ■ GbE & USB 2.0 host interfaces Flexibility to meet a debug challenge any When configured as a protocol analyzer, the Sierra M6-1 offers all the protocol analysis features as o other products in the LeCroy SAS/SATA product line. The analyzer software off y fers an intuitive GUI combining easy setup with flexible data g y p analysis displays. Th packet view logically assembles frames and primitives that he are part of a specific SAS or SATA command. Users are able to quickly view the completion status of any command, which e is especially useful in addressing system-level debug challeng ges. Statistical reports provide event and error counters, as well as performance metrics, that give users a snapshot into c captured traces and rapid access to items of interest. InFusion™ Error Injection The Sierra M6-1 InFusion models perform as a stand-alone 1.5, 3 or 6 Gb/s version of the LeCroy InFusion Error Injector, allowing engineers to verify error recovery characteristics of th designs. An easy-to-use pop-up menu interface allows the heir creation of customized test scenarios in just minutes. The use can program on-the-fly modifications t any fi ld within any ti f t i dt t i i j t i t Th er th fl difi ti to field ithi frame, as the data moves across the link. Any primitive or dat pattern can be intercepted and changed to a different userta specified pattern. Examples include support for changing DWORD values, disconnecting links, and forcing various error conditions such as an intermittent CRC error or running dispar errors. This enables unprecedented corner case rity modification for SAS and SATA traffic, which is especially usef during final test and integration cycles. ful
Abrir o catálogo na página 1
Specifications Host Requirements Windows® 7, Windows XP, W Windows Vista® or Windows Server 2003; ® Pentium® II processor o greater; Intel or USB 2.0 or 100/1000 Etherne capable et Recording Memory Size 2 or 4 GB Data Rates Supported TA 1.5, 3 and 6 Gb/s SAS or SAT No. of Ports Supported 1 port per system Cascade Capability Up to 8 ports (8 systems) Host Interface seT USB 2.0 and 10/100/1000bas Ethernet Front Panel Indicators 5 LEDs each for Host and Device Ports (Trigger, Error, Link, Speed, Data); Pow LED; Status LED wer Front Panel Connectors Two internal SATA bus conne ectors (Host and...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Teledyne LeCroy Europe
-
T3DSO4000L-HD
19 Páginas
-
WaveRunner 8000HD
20 Páginas
-
HDO6000B
20 Páginas
-
T3DSOH1000 /T3DSOH1000-ISO
15 Páginas
-
T3DMM4-5 Digit Digital Multimeter
10 Páginas
-
T3DAQ1-16
16 Páginas
-
T3MIL50 Milli Ohm Meter
6 Páginas
-
T3PM1006 Digital Power Meter
8 Páginas
-
DCS025 Deskew Calibration Source
2 Páginas
-
PP007-WR PP007-WS Passive Probes
2 Páginas
-
Current Probes
4 Páginas
-
WavePro HD
20 Páginas
-
WaveRunner 9000
20 Páginas
-
T3DSO2000 Data Sheet Oscilloscopes
16 Páginas
-
T3DSO1000 Data Sheet Oscilloscopes
16 Páginas
-
PeRT3 Phoenix System
16 Páginas
-
DDR Test Suite
12 Páginas
-
LabMaster 10 Zi-A
28 Páginas
-
DEBUG IN HIGH DEFINITION HDO6000A
28 Páginas
-
WaveRunner 8000
24 Páginas
-
wavesurfer 510
20 Páginas
-
WaveAce 1000 and 2000 Oscilloscopes
8 Páginas
-
PP066 High Bandwidth Passive Probe
2 Páginas
-
ZD Series Active Differential Probes
4 Páginas
-
MDA800 Motor Drive Analyzers
8 Páginas
-
MIPI M-PHY Protocol Analyzer
4 Páginas
-
Transmission Line Probes
2 Páginas
-
WaveSurfer 10 Oscilloscope
12 Páginas
-
Summit T24 Analyzer
2 Páginas
-
SierraNet M168
4 Páginas
-
WaveExpert Sampling Oscilloscopes
16 Páginas
-
LabMaster 10 Zi Oscilloscopes
36 Páginas
-
LabMaster 9 Zi-A Oscilloscopes
36 Páginas
-
WaveMaster 8 Zi-A Oscilloscopes
36 Páginas
-
SDA 8 Zi-A Serial Data Analyzers
36 Páginas
-
DDA 8 Zi-A Disk Drive Analyzers
36 Páginas
-
WavePro 7 Zi-A Oscilloscopes
28 Páginas
-
SDA 7 Zi-A Serial Data Analyzers
28 Páginas
-
DDA 7 Zi-A Disk Drive Analyzers
28 Páginas
-
HRO 12-bit Oscilloscopes
8 Páginas
-
HDO8000 High Definition
20 Páginas
-
HDO6000 / HDO6000-MS High
20 Páginas
-
WaveRunner 6 Zi Oscilloscopes
28 Páginas
-
HDO4000 / HDO4000-MS High
16 Páginas
-
WaveSurfer 3000 Oscilloscopes
12 Páginas
-
WaveJet 300A Oscilloscopes
8 Páginas
-
WaveAce 100 and 200 Oscilloscopes
8 Páginas
-
Summit T3-16 Analyzer
2 Páginas
-
STX A6-4S SATA Protocol Analyzer
2 Páginas
-
Voyager M3i
8 Páginas
-
Kibra 380 DDR3 Protocol Analyzer
4 Páginas
-
High Voltage Differential Probes
2 Páginas
-
Differential Amplifiers
2 Páginas
-
Current Probes
7 Páginas
-
HFP SERIES ACTIVE PROBES
4 Páginas
-
HDO4000 High Definition Oscilloscopes
16 Páginas
-
LeCroy Kibra 480 Analyzer
4 Páginas
-
WaveRunner Xi-A / MXi-A Oscilloscopes
24 Páginas
-
Vehicle Bus Analyzers
2 Páginas
-
Signal Integrity Studio
4 Páginas
-
SPARQ
12 Páginas
-
LogicStudio
8 Páginas
-
ArbStudio
8 Páginas
-
PeRT3 Eagle System
8 Páginas
Catálogos arquivados
-
Oscilloscope Product Overview
4 Páginas