Excertos do catálogo

Watermanager solution DL.WMS/GPRS/R Version: 27.06.2012
Abrir o catálogo na página 1
Technical specifications datalogger Data transmission Version with GSM/GPRS Engine Quadband GPRS frequency bands GPRS 850 MHz, GPRS 900 MHz, GPRS 1800 MHz, GPRS 1900 MHz Transmission power Class 4 (2 W) at GPRS, class 1 (1W) at GPRS 1800 and GPRS 1900 SIM card supports 3 V SIM cards Antenna stub antenna: 900 / 1800 MHz or 1900 MHz (Gain 0 / 0 dB), planar antenna: 900 / 1800 MHz (0 / 0 dB) Transmission m2m (machine to machine) protocol Datalogger Housing Stainless steel (316L / 1.4404) / Murytal C Antenna connector FME (male) Interface Radio 433 MHz Power supply 2 x 1.5 V alkali or 1 x 3.6 V...
Abrir o catálogo na página 2
Data query Automatic data query and administration of datalogger Access security 1 level with password protection Alarm function Transmission of several alarms via SMS and E-Mail Data transmission GPRS / m2m (machine to machine) protocol Configuration Sample- and storage rate, Identification (f.e. measuring site), Tare; the datalogger stores the height of the air column, and not the pressure at the sensor, Taring of measurement value; define threshold values, Alarm threshold value; Storage of the measurement data within the defined range, Density of the measuring medium; Set the density of...
Abrir o catálogo na página 3
Technical specifications ATM.WMS Pressure measuring range (mH2O) 1 ... 5 > 5 ... 20 > 20 ... 250 Overpressure 3 bar 3 x FS Burst pressure > 200 bar > 200 bar > 200 bar -5...50°C (typ. / max.) 0.8 / 1.0 0.3 / 0.5 0.3 / 0.5 -5...80°C (typ. / max.) 1.3 / 1.5 0.75 / 1.0 0.75 / 1.0 Response time, (typ.) < 1ms / 10...90% < 1ms / 10...90% < 1ms / 10...90% Long term stability, (3) < 0.5% FS / < 4 mbar < 0.2% FS / < 4 mbar < 0.1% FS / < 0.2% FS Accuracy, (1), (± %FS) Total Error, (2), (± % FS) (1) Zero based accuracy according to DIN16086, incl. hysteresis and repeatability at ambient temperature...
Abrir o catálogo na página 4
Additional documents Manual Article number 10.00.0205 DEB016 Operating and safety instructions Article number 10.88.0092 DMM029
Abrir o catálogo na página 5
Level transmitter without ballast weight with ballast weight_ Specifications may change without notice. STS Sensor Technik Sirnach AG Rutihofstrasse 8, 8370 Sirnach, Switzerland 844 Route de la Caille, 74350 Allonzier la Caille, France STS Sensoren Transmitter Systeme GmbH Poststrasse 7, 71063 Sindelfingen, Germany Higham Dairy Farm, Bumphill Lane, Alfreton | Derbyshire | Great Britain, DE55 6AH Via Gesu 5, 20090 Opera (Milano), Italy
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos STS Sensor Technik Sirnach AG
-
INDUSTRY PRODUCT
10 Páginas
-
TEST & MEASUREMENT PRODUCT OVERVIEW
6 Páginas
-
WATER & ENVIRONMENT
6 Páginas
-
Business competence brochure
6 Páginas
-
DL.WMS/GPRS/R/SDI-12
8 Páginas
-
ATM/N - Analog Level Transmitter
7 Páginas
-
ATM/IS - Analog Pressure Transmitter
8 Páginas
-
Product overview Industry
2 Páginas
-
Product overview Water
2 Páginas
-
Accessories
24 Páginas
-
ATM/F Hygienic Pressure Transmitter
6 Páginas
-
ATM/GR Electronic pressure switch
7 Páginas
-
ATM/K/N - Analog Level Transmitter
5 Páginas
-
ATM/N/IS Analog Level Transmitter
6 Páginas
-
DL.WMS/GPRS/R/SDI-12 Water Manager
7 Páginas
-
TS 100 Temperature Transmitter
5 Páginas
-
STS Products&Systems
64 Páginas
-
Industry Product Overview
2 Páginas
-
TM/N Passive pressure transmitter
6 Páginas