Excertos do catálogo

Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS • Certificate: FM, FM-C & IECEx & ATEX • Entry level series into precision pressure measurement • High accuracy is ensured by sophisticated digital temperature compensation algorithms • Fast customization thanks to configurable product design • Reverse polarity and short circuit protected, with integrated overvoltage protection
Abrir o catálogo na página 1
Long term stability, (7) < 0.5% FS / < 4 mbar < 0.2% FS / < 4 mbar < 0.1% FS / < 0.2% FS Burst pressure, (4) > 850 / < 1500 bar > 1500 bar Response time, (typ.) < 1ms / 10 ... 90% FS < 1ms / 10 ... 90% FS Long term stability, (7) < 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS (2) Overpressure and burst pressure 1500 bar (stainless steel) optional (3) Process connection frontal and flush diaphragm availables 600 bar (5) Zero based accuracy according to DIN-16086, incl. hysteresis and repeatability at ambient temperature (6) Total error including accuracy and...
Abrir o catálogo na página 2
Power supply Supply influence Circuit diagram Load resistance Load influence < 0.05% FS Reverse polarity protection Pout to +Vin Certificate, (1) SEV 09 ATEX 0108 X IECEx SEV 10.0003 X IECEx MSC 14.0002 X Dust II 1D Ex ia IIIC IP6x T140°C EN 61241-0 / -11 intrinsically safe circuit (1) For detailed Ex specifications see certificate and operating and safety instructions (2) Without any information about temperature class the transmitter will be delivered for T4
Abrir o catálogo na página 3
Description Level Typical interferences mmpp) EN 60068-2-27 Shock 100 G (impulse duration 6 ms) EN 55022 Emission, class B < 30 dBpV/m (0.03 ... 1 EN 61000-4-3 Irradiated RF 10V/m (0.08 ... 2.7 GHz, 3s) Radio sets, wireless phones EN 61000-4-4 Transients (burst) 4 kV Motors, valves Line-Earth: 1 kV/42 Q EN 61000-4-6 Conducted RF 3 V (0.15 ... 80 MHz, 3 s) Frequency converters Transducer Stainless steel (316L / 1.4404) Seals Viton (Standard), EPDM,
Abrir o catálogo na página 4
Cable Socket Connector Article number
Abrir o catálogo na página 5
(3) Process connection available < 600 bar (4) Cable socket connector not included (5) Please specify the required cable length and medium (6) For operating temperature > 50°C, FEP cable must be used (7) Only with pressure connection Fig. 2, Fig. 3, Fig. 6 and Fig. 7 (16) Connector side not to be used in Zone 0 or Ex ia IIC, explosion risk
Abrir o catálogo na página 7
Pressure connections Electrical Connections Version for medium temperature up to 125°C Pin 2-wire L - 25 mm for connector DIN 43650 E EP (only Ex) Version for medium temperature >125°C up to 150°C socket connector L ^ 52 mm for connector DIN 43650 Pin 2-wire UiTTF 5 EP (only Ex) socket connector Pin 2-wire white +Vin yellow Pout socket connector 3 Pout 4 +Vin Specifications may change without notice. STS Headquarters, Switzerland: STS Sensor Technik Sirnach AG Rutihofstrasse 8 | 8370 Sirnach | Switzerland sales@stssensors.com | www.stssensors.com STS Germany: STS Sensoren Transmitter...
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos STS Sensor Technik Sirnach AG
-
INDUSTRY PRODUCT
10 Páginas
-
TEST & MEASUREMENT PRODUCT OVERVIEW
6 Páginas
-
WATER & ENVIRONMENT
6 Páginas
-
Business competence brochure
6 Páginas
-
DL.WMS/GPRS/R/SDI-12
8 Páginas
-
ATM/N - Analog Level Transmitter
7 Páginas
-
ATM/IS - Analog Pressure Transmitter
8 Páginas
-
Product overview Industry
2 Páginas
-
Product overview Water
2 Páginas
-
Accessories
24 Páginas
-
ATM/F Hygienic Pressure Transmitter
6 Páginas
-
ATM/GR Electronic pressure switch
7 Páginas
-
ATM/K/N - Analog Level Transmitter
5 Páginas
-
ATM/N/IS Analog Level Transmitter
6 Páginas
-
DL.WMS/GPRS/R/SDI-12 Water Manager
7 Páginas
-
TS 100 Temperature Transmitter
5 Páginas
-
STS Products&Systems
64 Páginas
-
Industry Product Overview
2 Páginas
-
TM/N Passive pressure transmitter
6 Páginas
-
DL.WMS/GPRS/R
8 Páginas