Soft Start-up Valve
1 / 16Páginas

{{requestButtons}}

Excertos do catálogo

Soft Start-up Valve - 1

Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply New C € crqhs) Power consumption: 0.35 W * At 12/24 V DC Current model: 1.8 W (80 % reduction) Improved flow rate characteristics: Up to 2.2 times Q[l/min (ANR)]: 2433 Energy saving No air flow when the main valve is switched.

Abrir o catálogo na página 1
Soft Start-up Valve - 2

Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series ∗1 Improved flow rate characteristics : Up to 2.2 times Q[l/min (ANR)]: 2433 Fill time: Up to 50 % shorter ∗1 For high speed air supply Body size Current model High speed air supply Current model Current model Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Air flow rate [l/min (ANR)] Current model 2 3 4 Number of needle rotations Smaller profile and less work hours due to integrated silencer Built-in silencer (Option) When the silencer is mounted afterward: Silencer part number (when mounted...

Abrir o catálogo na página 2
Soft Start-up Valve - 3

Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series Variations Q ∗1 C [l/min (ANR)] [dm3/(s·bar)] Electrical entry • Bracket • Pressure gauge • Silencer (Built-in) ∗1 These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa. ∗2 Only for the DC type. Pilot Valve Variations DIN terminal minal with connector nnector DIN terminal without connector ∗1 A DIN terminal conforming to EN-175301-803C (former DIN 43650C) Pressure gauge Manual Override Variations...

Abrir o catálogo na página 3
Soft Start-up Valve - 4

Body size *1 The 110 V AC and 115 V AC are interchangeable. The 220 V AC and 230 V AC are interchangeable as well. The allowable voltage fluctuation is -15 % to +5 % of the rated voltage for the 115 V AC or 230 V AC. *2 Only for the DC type. *3 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN 43650C). *4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. *5 Only for the NPT thread • Option: Select one each for a to c. • Option symbol: When more than one specification is required, indicate in alphabetical order. Example) AV2000-02BGS

Abrir o catálogo na página 4
Soft Start-up Valve - 5

*1 These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa. Number of needle rotations

Abrir o catálogo na página 5
Soft Start-up Valve - 6

*1 Bracket: 1 pc., Mounting screw: 2 pcs. (3 pcs. for AV5000-A) *2 Element, Element O-ring, Element cover: 1 pc. for each *3 □ of the pressure gauge part number will indicate the connecting screw type. No indication is necessary for R; however, indicate N for NPT. Please contact SMC regarding the pressure gauge supply for psi unit specifications. Spacer with bracket *1 Except port size 06 Assembly Example © Spacer with bracket Products do not come assembled. They should be ordered separately and assembled by the customer. * The Simple Specials System deals with product unification. Please...

Abrir o catálogo na página 6
Soft Start-up Valve - 7

Working conditions Pilot valve Pressure conditions Operation description Internal construction/Cylinder actuation circuit (Meter-out control) example Operation description of the soft start-up valve When the pilot valve © is energised or turned ON manually, the spool © is pushed down due to the pilot air and gets into contact with the valve ©, closing the flow passage to port 3 (R). At this time, force that pushes the valve © > force that pushes down the spool ©. Therefore, the flow passage from the valve © to port 2 (A) is still closed. Furthermore, the piston © is pushed down due to the...

Abrir o catálogo na página 7
Soft Start-up Valve - 8

*1 See below for How to Order of the pilot valve. How to Order Pilot Valve Assembly *1 The 110 V AC and 115 V AC are interchangeable. The 220 V AC and 230 V AC are interchangeable as well. The allowable voltage fluctuation is -15 % to +5 % of the rated voltage for the 115 V AC or 230 V AC. *2 Only for the DC type. *3 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN 43650C). *4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. 7

Abrir o catálogo na página 8
Soft Start-up Valve - 9

Soft Start-up Valve Dimensions Grommet: AV२00-२-२G२२-२-A AV5000-A Flow adjustment needle at low speed air supply Approx. 300 mm (Lead wire length) Manual override Pressure gauge port size 1/8 Pressure gauge (Option) Ø 37.5 Built-in silencer (Option) Bracket (Option) [mm] Standard specifications Port size Width across flats 22 Width across flats 24 Width across flats 30 Width across flats 36 [mm] Optional specifications With bracket With built-in silencer Width across flats 14 Width across flats 19 Width across flats 22

Abrir o catálogo na página 9
Soft Start-up Valve - 10

AV2000-A/3000-A/4000-A/5000-A Series Dimensions DIN terminal: AV२00-२-२D/Y२२-२-A AV5000-A Flow adjustment needle at low speed air supply Pressure gauge port size 1/8 Pressure gauge (Option) Bracket (Option) Built-in silencer (Option) Manual override [mm] Standard specifications Port size Width across flats 22 Width across flats 24 Width across flats 30 Width across flats 36 [mm] Optional specifications With bracket With built-in silencer Width across flats 14 Width across flats 19 Width across flats 2

Abrir o catálogo na página 10
Soft Start-up Valve - 11

AV2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: http://www.smc.eu 2. Holding pressure Since the valve might have slight internal leakage, it is not suitable for holding pressure in a tank or another vessel for a long period of time. 3. Not suitable for use as an emergency shutoff valve etc. The valves listed in this catalogue are not designed for...

Abrir o catálogo na página 11
Soft Start-up Valve - 12

A V2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: http://www.smc.eu 1. To perform the initial speed adjustment of the outlet side actuator, supply air from this valve’s inlet side and turn ON the pilot valve. Then, rotate the needle counterclockwise from the fully closed position. 1. Preparation before piping Before piping is connected, it should be...

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos SMC

  1. Serie HRR

    64 Páginas

  2. Série VP/VG

    33 Páginas

  3. Série XL

    27 Páginas

  4. Série ACG/ARG/AWG

    45 Páginas

  5. Série JXC5H/6H

    36 Páginas

  6. JMB series

    13 Páginas

  7. JCM series

    21 Páginas

  8. PF3A7*H

    40 Páginas

  9. PF3W

    34 Páginas

  10. Water Treatment

    16 Páginas

  11. Vacuum Pad

    16 Páginas

  12. One-touch Fittings

    224 Páginas

  13. Electric Actuator

    272 Páginas

  14. Rotary Actuator

    40 Páginas

  15. Compact Slide

    24 Páginas

  16. Air Cylinder

    124 Páginas

  17. LEFB, LEFG-BS series

    180 Páginas

  18. JMGP series

    16 Páginas

  19. ISO Cylinder

    32 Páginas

  20. IZD10

    20 Páginas

  21. IZH10

    8 Páginas

  22. Fan Type Lonizer

    28 Páginas

  23. Check Valves

    4 Páginas

  24. Series ZL

    20 Páginas

  25. Series CM2

    92 Páginas

  26. Series IDGA/IDG

    56 Páginas

  27. IDH-A

    12 Páginas

  28. CP96-C96-B

    74 Páginas

  29. CVQ

    24 Páginas

  30. HY

    52 Páginas

  31. VNA

    10 Páginas

  32. Series MXY

    28 Páginas

  33. Series MXP

    39 Páginas

  34. Air Slide Table

    132 Páginas

  35. S0700

    112 Páginas

  36. SYJ

    96 Páginas

  37. SY - NEW

    164 Páginas

  38. VF

    60 Páginas

  39. C(D)55 series

    24 Páginas

  40. C(D)Q2 series

    216 Páginas

  41. MGP series

    36 Páginas

  42. 11-LEFS series

    19 Páginas

  43. LECS series

    16 Páginas

  44. LECPA series

    4 Páginas

  45. KQ series

    80 Páginas

  46. IDF series

    16 Páginas

  47. ZP series

    69 Páginas

  48. MHF series

    32 Páginas

  49. MHZ series

    68 Páginas

  50. CRB series

    44 Páginas

  51. MGJ series

    7 Páginas

  52. AC series

    98 Páginas

  53. VH series

    14 Páginas

  54. LVA series

    43 Páginas

  55. VDW series

    28 Páginas

  56. LVM series

    28 Páginas

  57. VX2 series

    32 Páginas

  58. MXH series

    32 Páginas

  59. MXF series

    12 Páginas

  60. CXW series

    48 Páginas

  61. CXS series

    76 Páginas

  62. CQS series

    40 Páginas

  63. CQM series

    28 Páginas

  64. CLQ series

    36 Páginas

Catálogos arquivados

  1. KR

    7 Páginas

  2. KF

    16 Páginas

  3. AFF

    80 Páginas

  4. HAA

    3 Páginas

  5. ZFA

    14 Páginas

  6. ZA

    13 Páginas

  7. D

    117 Páginas

  8. RB

    23 Páginas

  9. cep

    44 Páginas

  10. rsq

    30 Páginas

  11. CLK

    51 Páginas

  12. MK

    20 Páginas

  13. CLJ

    65 Páginas

  14. ARG

    48 Páginas

  15. VXA

    17 Páginas

  16. MXU

    12 Páginas