Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply New C € crqhs) Power consumption: 0.35 W * At 12/24 V DC Current model: 1.8 W (80 % reduction) Improved flow rate characteristics: Up to 2.2 times Q[l/min (ANR)]: 2433 Energy saving No air flow when the main valve is switched.
Abrir o catálogo na página 1
Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series ∗1 Improved flow rate characteristics : Up to 2.2 times Q[l/min (ANR)]: 2433 Fill time: Up to 50 % shorter ∗1 For high speed air supply Body size Current model High speed air supply Current model Current model Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Air flow rate [l/min (ANR)] Current model 2 3 4 Number of needle rotations Smaller profile and less work hours due to integrated silencer Built-in silencer (Option) When the silencer is mounted afterward: Silencer part number (when mounted...
Abrir o catálogo na página 2
Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series Variations Q ∗1 C [l/min (ANR)] [dm3/(s·bar)] Electrical entry • Bracket • Pressure gauge • Silencer (Built-in) ∗1 These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa. ∗2 Only for the DC type. Pilot Valve Variations DIN terminal minal with connector nnector DIN terminal without connector ∗1 A DIN terminal conforming to EN-175301-803C (former DIN 43650C) Pressure gauge Manual Override Variations...
Abrir o catálogo na página 3
Body size *1 The 110 V AC and 115 V AC are interchangeable. The 220 V AC and 230 V AC are interchangeable as well. The allowable voltage fluctuation is -15 % to +5 % of the rated voltage for the 115 V AC or 230 V AC. *2 Only for the DC type. *3 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN 43650C). *4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. *5 Only for the NPT thread • Option: Select one each for a to c. • Option symbol: When more than one specification is required, indicate in alphabetical order. Example) AV2000-02BGS
Abrir o catálogo na página 4
*1 These values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa. Number of needle rotations
Abrir o catálogo na página 5
*1 Bracket: 1 pc., Mounting screw: 2 pcs. (3 pcs. for AV5000-A) *2 Element, Element O-ring, Element cover: 1 pc. for each *3 □ of the pressure gauge part number will indicate the connecting screw type. No indication is necessary for R; however, indicate N for NPT. Please contact SMC regarding the pressure gauge supply for psi unit specifications. Spacer with bracket *1 Except port size 06 Assembly Example © Spacer with bracket Products do not come assembled. They should be ordered separately and assembled by the customer. * The Simple Specials System deals with product unification. Please...
Abrir o catálogo na página 6
Working conditions Pilot valve Pressure conditions Operation description Internal construction/Cylinder actuation circuit (Meter-out control) example Operation description of the soft start-up valve When the pilot valve © is energised or turned ON manually, the spool © is pushed down due to the pilot air and gets into contact with the valve ©, closing the flow passage to port 3 (R). At this time, force that pushes the valve © > force that pushes down the spool ©. Therefore, the flow passage from the valve © to port 2 (A) is still closed. Furthermore, the piston © is pushed down due to the...
Abrir o catálogo na página 7
*1 See below for How to Order of the pilot valve. How to Order Pilot Valve Assembly *1 The 110 V AC and 115 V AC are interchangeable. The 220 V AC and 230 V AC are interchangeable as well. The allowable voltage fluctuation is -15 % to +5 % of the rated voltage for the 115 V AC or 230 V AC. *2 Only for the DC type. *3 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN 43650C). *4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected. 7
Abrir o catálogo na página 8
Soft Start-up Valve Dimensions Grommet: AV२00-२-२G२२-२-A AV5000-A Flow adjustment needle at low speed air supply Approx. 300 mm (Lead wire length) Manual override Pressure gauge port size 1/8 Pressure gauge (Option) Ø 37.5 Built-in silencer (Option) Bracket (Option) [mm] Standard specifications Port size Width across flats 22 Width across flats 24 Width across flats 30 Width across flats 36 [mm] Optional specifications With bracket With built-in silencer Width across flats 14 Width across flats 19 Width across flats 22
Abrir o catálogo na página 9
AV2000-A/3000-A/4000-A/5000-A Series Dimensions DIN terminal: AV२00-२-२D/Y२२-२-A AV5000-A Flow adjustment needle at low speed air supply Pressure gauge port size 1/8 Pressure gauge (Option) Bracket (Option) Built-in silencer (Option) Manual override [mm] Standard specifications Port size Width across flats 22 Width across flats 24 Width across flats 30 Width across flats 36 [mm] Optional specifications With bracket With built-in silencer Width across flats 14 Width across flats 19 Width across flats 2
Abrir o catálogo na página 10
AV2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 1 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: http://www.smc.eu 2. Holding pressure Since the valve might have slight internal leakage, it is not suitable for holding pressure in a tank or another vessel for a long period of time. 3. Not suitable for use as an emergency shutoff valve etc. The valves listed in this catalogue are not designed for...
Abrir o catálogo na página 11
A V2000-A/3000-A/4000-A/5000-A Series Specific Product Precautions 2 Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: http://www.smc.eu 1. To perform the initial speed adjustment of the outlet side actuator, supply air from this valve’s inlet side and turn ON the pilot valve. Then, rotate the needle counterclockwise from the fully closed position. 1. Preparation before piping Before piping is connected, it should be...
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos SMC
-
In-line Type Vacuum Ejector
6 Páginas
-
Serie HRR
64 Páginas
-
Série VP/VG
33 Páginas
-
Série XL
27 Páginas
-
Série ACG/ARG/AWG
45 Páginas
-
Série JXC5H/6H
36 Páginas
-
LEJS100-X400 series
15 Páginas
-
JMB series
13 Páginas
-
JCM series
21 Páginas
-
PF3A7*H
40 Páginas
-
PF3W
34 Páginas
-
High-Precision Digital Pressure Switch
40 Páginas
-
Compact Guide Cylinder with Lock
36 Páginas
-
Locally Manufactured and Assembled
4 Páginas
-
Water Treatment
16 Páginas
-
Food & Packaging Industry
4 Páginas
-
Digital Gap Checker
26 Páginas
-
Vacuum Pad
16 Páginas
-
One-touch Fittings
224 Páginas
-
Electric Actuator
272 Páginas
-
Rotary Actuator
40 Páginas
-
Compact Guide Cylinder
18 Páginas
-
Compact Slide
24 Páginas
-
Air Cylinder
124 Páginas
-
LEFB, LEFG-BS series
180 Páginas
-
JMGP series
16 Páginas
-
High-Precision Digital Pressure Switch
16 Páginas
-
ISO Cylinder
32 Páginas
-
IZD10
20 Páginas
-
IZH10
8 Páginas
-
Fan Type Lonizer
28 Páginas
-
Check Valves
4 Páginas
-
Colour Display Digital Pressure Switch
20 Páginas
-
Compact Cylinder/Clean series
16 Páginas
-
3 port solenoid Valve
74 Páginas
-
Vacuum Ejector Series ZM
20 Páginas
-
Series ZL
20 Páginas
-
Series CM2
92 Páginas
-
Series IDGA/IDG
56 Páginas
-
Platform Cylinder Series CXT
14 Páginas
-
IDH-A
12 Páginas
-
CP96-C96-B
74 Páginas
-
CVQ
24 Páginas
-
HY
52 Páginas
-
VNA
10 Páginas
-
Series MXY
28 Páginas
-
Series MXP
39 Páginas
-
Air Slide Table
132 Páginas
-
Compact Cylinder Series CQ2
138 Páginas
-
S0700
112 Páginas
-
SYJ
96 Páginas
-
SY - NEW
164 Páginas
-
VF
60 Páginas
-
C(D)55 series
24 Páginas
-
C(D)Q2 series
216 Páginas
-
MGP series
36 Páginas
-
11-LEFS series
19 Páginas
-
LECS series
16 Páginas
-
LECPA series
4 Páginas
-
KQ series
80 Páginas
-
IDF series
16 Páginas
-
ZP series
69 Páginas
-
MHF series
32 Páginas
-
MHZ series
68 Páginas
-
CRB series
44 Páginas
-
MGJ series
7 Páginas
-
AC series
98 Páginas
-
VH series
14 Páginas
-
LVA series
43 Páginas
-
VDW series
28 Páginas
-
LVM series
28 Páginas
-
VX2 series
32 Páginas
-
MXH series
32 Páginas
-
MXF series
12 Páginas
-
CXW series
48 Páginas
-
CXS series
76 Páginas
-
CQS series
40 Páginas
-
CQM series
28 Páginas
-
CLQ series
36 Páginas