Fieldbus System (For Input/Output)
1 / 16Páginas

{{requestButtons}}

Excertos do catálogo

Fieldbus System (For Input/Output) - 1

General-purpose connectors Push Pull connectors One-touch removal/mounting requires fewer work-hours *1 Abbreviation of the Automation Initiative of German (Deutschland) Automobile Manufacturers • PROFIenergy • Shared Device Power supply connector: 7/8 inch Compatible with new functions of • NET Load Class H • MRPD Push Pull connectors Digital input module Digital output module FW (firmware) update function Simultaneous writing is possible from network connection. Web server function Status check and valve ON/OFF are possible on the web browser. Existing model Compact, Lightweight Height: 40 mm reduction Weight: 53.5% reduction (@w465 g b Existing model: 1000 g

Abrir o catálogo na página 1
Fieldbus System (For Input/Output) - 2

Fieldbus System (For Input/Output) EX245 Series Compatible with PROFIenergy, the energy-saving function Generally, the switching off of the facilities in factories consumes a lot of time to restart them. PROFIenergy enables PROFINET communication to continue while saving energy by minimizing the time for restarting. When the commands for PROFIenergy energy-saving mode are sent from the I/O controller (PLC) to the I/O device (SI unit), the information of time for pausing is also sent (such as lunch breaks, nighttime, weekends, holidays). The SMC SI unit does not require time for restarting....

Abrir o catálogo na página 2
Fieldbus System (For Input/Output) - 3

Fieldbus System (For Input/Output) EX245 Series MRP/MRPD function MRP (Media Redundancy Protocol) function Even if a communication cable is disconnected or damaged at any location, communication can be continued. Furthermore, it is possible to identify the disconnection point, and the network disconnection time can be made within 200 ms. Normal flow of data Redundancy manager Data flow when the communication cable is disconnected Redundancy manager Client w Disconnected Client e * o use the MRP function, the PLC should be T able to support the MRP function. MRPD (Media Redundancy for...

Abrir o catálogo na página 3
Fieldbus System (For Input/Output) - 4

Fieldbus System (For Input/Output) EX245 Series Fast Start Up function For the Fast Start Up function, time from power ON to communication connection Save time when connecting and improve productivity In the case of a tool changer, it takes about 10 seconds for communication to be connected in some products after the power to the device installed on the tool is turned ON. For products which support the Fast Start Up function, communication can be operational even faster. * o use the Fast Start Up function, the PLC should be T able to support the Fast Start Up function. Fiber-optic cable...

Abrir o catálogo na página 4
Fieldbus System (For Input/Output) - 5

CONTENTS Fieldbus System (For Input/Output) EX245 Series

Abrir o catálogo na página 5
Fieldbus System (For Input/Output) - 6

Fieldbus System For Input/Output Connector type Digital Input Module EX245-DX1 EX245 -EA2- Digital input module specification Digital input (16 inputs) Digital Output Module EX245-DY1 Digital output module specification Digital output (8 outputs) Refer to the Web Catalog for manifold valve part numbers. Bracket 3 to 5 correspond to the mounting hole pitch of each manifold valve.

Abrir o catálogo na página 6
Fieldbus System (For Input/Output) - 7

Fieldbus System For Input/Output EX24o Series Common Specifications for All Units/Modules *1 The configuration file can be downloaded from the SMC website, https://www.smcworld.com Digital Input Module *1 An M12 (4-pin) connector can also be connected. Digital Output Module *1 An M12 (4-pin) connector can also be connected.

Abrir o catálogo na página 7
Fieldbus System (For Input/Output) - 8

EX245 Series Dimensions/Parts Description SI Unit EX245-SPN1A/2A PROFINET connection port M12 connector (4-pin, Socket, D-coded) Power supply connector 7/8 inch connector (5-pin, Socket) PROFINET connection port Push Pull connector EX245-SPN1A: SCRJ EX245-SPN2A: RJ45 Product label Power supply connector Push Pull connector (24 V) Digital Input Module EX245-DX1 Power supply connector 7/8 inch connector (5-pin, Plug) Digital Output Module EX245-DY1 Input connector 8 x M12 connector (5-pin, Socket) Output connector 4 x M12 connector (5-pin, Socket) LED indicator (ON/OFF of the output device)...

Abrir o catálogo na página 8
Fieldbus System (For Input/Output) - 10

EX245 Series Assembly Examples Manifold valve  SI unit  Digital input module  Digital output module  End plate   Refer to the Web Catalog for order numbers.  EX245-SPN1A  EX245-DX1  EX245-DY1  EX245-EA2-3 The modules and manifold valve are not assembled at the time of shipment. After assembling the SI unit and manifold valve, assemble the modules. Width across flats: 2.5 mm∗1 Tightening torque JSY : 0.75 to 0.85 N·m SY : 0.75 to 0.85 N·m VQC : 0.5 to 0.7 N·m Manifold valve Manifold valve SI unit Digital input module Digital output module End plate (With bracket) *1 Tightening tool is not...

Abrir o catálogo na página 10
Fieldbus System (For Input/Output) - 11

t Communication cable/connector y Field-wireable communication connector u I/O cable with connector, I/O connector q Seal cap q Seal cap w Marker r 7/8 inch connector and related parts Be sure to mount a seal cap on any unused I/O connectors. Otherwise, the specified enclosure cannot be maintained. The signal name of I/O device and each module name can be entered and mounted on each module. For power supply connectors (10 pcs.) Seal cap for communication connector and power supply connector are included when EX245-SPN1A/2A is shipped (2 caps for each unit). r 7/8 Inch Connector and Related...

Abrir o catálogo na página 11
Fieldbus System (For Input/Output) - 12

t Communication Cable/Connector EX9-AC 005 EN-PSPS (With connector on both sides (Plug/Plug)) Terminal Core wire no. color Plug connector pin arrangement Metal part^^Shield Yellow White Orange Blue Metal parts Connections (Straight cable) Signal name TD+ RD+ TD-RD-Plug connector pin arrangement D-coded EN-PAPA (With angled connector on both sides (Plug/Plug)) Metal parts M12 SPEEDCON Plug connector pin arrangement D-coded sMetalparts Shield Metal parts Connections (Straight cable) Plug connector pin arrangement D-coded

Abrir o catálogo na página 12
Fieldbus System (For Input/Output) - 13

Terminal Signal name no. Terminal Core wire no. color Plug connector pin arrangement D-coded Green Metal parts Connections (Straight cable) Plug connector pin arrangement 0 Field-wireable Communication Connector PCA-1446553 D-coded Applicable Cable * The table above shows the specifications for the applicable cable. Adaptation for the connector may vary on account of the conductor construction of the electric wire.

Abrir o catálogo na página 13

Todos os catálogos e folhetos técnicos SMC PNEUMATIC

  1. Vacuum Unit 2024

    99 Páginas

  2. AS-FS Series

    36 Páginas

  3. IDF series

    12 Páginas

  4. MHL2 Series

    24 Páginas

  5. JCM Serie

    18 Páginas

  6. EX245 Series

    12 Páginas

  7. SY

    268 Páginas

  8. 5-p0966-0971-lmu

    5 Páginas

  9. es70-44c-vx2

    52 Páginas

  10. es50-37-kq2

    124 Páginas

  11. ex-pcw

    23 Páginas

  12. 1-p2124-2152-ex510

    29 Páginas

  13. 1-p2111-2122-ex500

    12 Páginas

  14. 1-p2063-2073-ex260

    11 Páginas

  15. es20-230b-crb2

    59 Páginas

  16. VH

    9 Páginas

  17. CUJ

    41 Páginas

  18. AL

    3 Páginas

  19. kj mm

    9 Páginas

  20. AQ

    4 Páginas

  21. SY3000/5000-X13

    2 Páginas

  22. Series MB

    24 Páginas

  23. Series LES

    23 Páginas

  24. Series LEFB

    16 Páginas

  25. Series PF3W

    28 Páginas

  26. Series IDG?A/IDG

    56 Páginas

  27. Floating Joint

    7 Páginas

  28. Series IZS40/41/42

    32 Páginas

  29. Series LEY

    7 Páginas

  30. Series VHS

    12 Páginas

  31. Series CY1S

    28 Páginas

  32. SeriesCQ2/CQS/CQ

    4 Páginas

  33. In-line Air Filter

    12 Páginas

  34. Series CQ2/CQS

    2 Páginas

  35. AS series

    2 Páginas

  36. corporate guide

    13 Páginas

  37. ZP

    69 Páginas

  38. ZFA

    14 Páginas

  39. ZA

    13 Páginas

  40. MHF

    32 Páginas

  41. MHZ

    68 Páginas

  42. CRB

    44 Páginas

  43. D

    117 Páginas

  44. RB

    23 Páginas

  45. CEP

    44 Páginas

  46. RSK

    30 Páginas

  47. CLK

    51 Páginas

  48. MK

    20 Páginas

  49. GLJ

    65 Páginas

  50. MGJ

    7 Páginas

  51. Mx

    36 Páginas

  52. MXH

    18 Páginas

  53. My3

    56 Páginas

  54. my1b

    20 Páginas

  55. CC

    15 Páginas

  56. J

    14 Páginas

  57. CQ2

    51 Páginas

  58. standard cylinder

    84 Páginas

  59. VFN

    6 Páginas

  60. SY3000

    246 Páginas

  61. SJ3A6

    18 Páginas

  62. 1301/IW

    14 Páginas

  63. CHQ/CHDQ

    19 Páginas

  64. AC

    95 Páginas

  65. HAW

    4 Páginas

  66. HAA

    3 Páginas

  67. ZB

    24 Páginas

  68. CRB2

    35 Páginas

  69. CJ1

    5 Páginas

  70. SYJ

    62 Páginas

  71. SJ

    78 Páginas

Catálogos arquivados