Excertos do catálogo

Description The SIPROTEC 7VK87 circuit breaker management device has specifically been designed for circuit-breaker management. With its modular structure, flexibility and the powerful DIGSI 5 engineering tool, the SIPROTEC 7VK87 device offers future-oriented solutions for protection, control, automation, monitoring, and Power Quality - Basic. Main function Automatic reclosing, synchrocheck, circuit breaker failure protection Tripping 1-pole and 3-pole or 3-pole Inputs and out- 12 predefined standard variants with 4/4 puts or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs Hardware flexibi- Flexibly adjustable I/O quantity structure lity within the scope of the SIPROTEC 5 modular system DIGSI 5 permits all functions to be configured and com bined as required. Housing width 1/3 x 19 inch to 2/1 x 19 inch Applications • Automatic reclosing after 1/3-pole tripping • Synchrocheck before reclosing • Circuit-Breaker Failure Protection • Also used in switchgear with breaker-and-a-half layout • Backup overcurrent and voltage protection • Serial protection communication with SIPROTEC 5 and SIPROTEC 4 devices over different distances and physical media, such as optical fiber, two-wire connections, and communication networks • Phasor Measurement Unit (PMU) • Detection and recording of power-quality data in the medium-voltage and subordinate low-voltage power system Functions
Abrir o catálogo na página 1
• 1 -pole automatic reclosing function secondary arc de Siemens Sans Bold 9pt Siemens Sans Roman 9pt 75 Lorem ipsum dolor Consecte tuer Adipiscing 10256 Dolor sit amet sit amet 75 Lorem ipsum dolor Consecte tuer Adipiscing 10256 tection (SAD) • Circuit-breaker failure protection for 1 -pole and 3-pole tripping • Point-on-wave switching • Control, synchrocheck, and switchgear interlocking protection • Voltage controller for transformers • Fault locator plus for accurate fault location with in-homogenous line sections and targeted automatic overhead-line section reclosing (AREC) • Arc...
Abrir o catálogo na página 2
• IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO, PROFINET IO S2 redundancy) • Virtual network partitioning (IEEE 802.1Q - VLAN) • Serial protection communication via optical fibers, two-wire connections, and communication networks (IEEE C37.94 and others), including automatic switchover between ring and chain topology. • PQ - Basic: Voltage unbalance; voltage changes: overvoltage, dip, interruption; TDD, THD, and harmonics • Reliable data transmission via PRP and HSR redundancy protocols • Extensive cybersecurity functionality, such as role-based access control (RBAC),...
Abrir o catálogo na página 3Todos os catálogos e folhetos técnicos SIEMENS Energy automation and smart grid
-
7SR5 Platform
86 Páginas
-
Reyrolle 7SR54
2 Páginas
-
Reyrolle 7SR51
2 Páginas
-
SICAM Q100
2 Páginas
-
Reyrolle 7SR17 Rho Motor Protection
2 Páginas
-
7SR17 Rho Motor Protection Relay
20 Páginas
-
7SR105 – Rho Motor protection relay
2 Páginas
-
7SR158 Argus Voltage and Frequency Relay
16 Páginas
-
7SR21 & 7SR22 Argus
2 Páginas
-
SIPROTEC 7UM85 Generator protection
2 Páginas
-
SIPROTEC 7SK85 Motor Protection
2 Páginas
-
SIPROTEC 7SK82 Motor Protection
2 Páginas
-
SIPROTEC 7SA87
2 Páginas
-
SIPROTEC 7SA86
2 Páginas
-
SIPROTEC 7SA82
2 Páginas
-
SICAM A8000 Series
11 Páginas
-
SICAM Power Quality and Measurement
42 Páginas
-
Catalog Reyrolle 7XG222 · Edition 1
16 Páginas
-
SICAM Substation Automation
190 Páginas
-
Reyrolle Product Catalogue
346 Páginas
-
Reyrolle 5 Platform
52 Páginas
-
SIPROTEC Compact
210 Páginas
-
SICAM - Substation Automation and RTUs Ed 2
198 Páginas
-
Catalog SICAM CMIC
8 Páginas
-
7SC80 Brochure
8 Páginas
-
Catalog - Bay Controller
32 Páginas