Digital Grid Reyrolle Test Block (7XG222) Catalog Devices and Application Digital Grid ■ Reyrolle Test Block (7XG222) Catalog ■ Siemens Protection Devices 3
Abrir o catálogo na página 3
Devices and Application 7XG222 2RMLG Test Block and 2RLMB-R Test Plug Description The 7XG222 range of test blocks, housed within an Epsilon enclosure, offers facilities for monitoring and secondary injection testing of power system protection schemes in conjunction with the appropriate multi-fingered test plug. The 2RMLG Test Block has 14 pairs of spring loaded contacts which are linked to a terminal block positioned at the rear of the enclosure. The 2RMLG07 is coded to only accept the 2RMLB-R7 Test Plug which has connection terminals 21, 23, 25, and 27, internally. The 2RMLG08 is coded to...
Abrir o catálogo na página 4
Hardware Construction The 2RMLG is a size E2 unit in the Epsilon range of enclosures. The rear terminal block has 28 terminals each with an M4 screw outlet for the attachment of external wiring, fitted with 'L' shaped pre-insulated ring tongue terminations. 2RMLB-R7 with Shorting Contacts The 2RMLB-R7 is similar to the 2RMLB-R1 with shorted contact pairs 21-23-25-27 and is coded to be used with the MMLG07 Test Socket only. 2RMLB-R8 with Shorting Contacts The 2RMLB-R8 is similar to the 2RMLB-R1 with shorted contact pairs 1-3, 5-7, 9-11, 15-17 and is coded to be used with the 2RMLG08 Test...
Abrir o catálogo na página 5
Technical Documentation Connection Diagrams Connection Diagrams Figure 3.1/1 Typical Application of the 2RMLG01 / 2RMLG02 Test Block and 2RMLB-R1 Test Plug NOTE 2RMLG01 13/14 open cct when cover is removed and all other positions are connected. 6 Digital Grid ⋅ Reyrolle Test Block (7XG222) Catalog ⋅ Siemens Protection Devices 2RMLG02 13/14 connected as in the same way as other positions
Abrir o catálogo na página 6
Technical Documentation Connection Diagrams Figure 3.1/2 Typical Application of the 2RMLG07 Test Block and 2RMLB-R7 Test Plug Digital Grid ⋅ Reyrolle Test Block (7XG222) Catalog ⋅ Siemens Protection Devices
Abrir o catálogo na página 7
Technical Documentation Connection Diagrams Figure 3.1/3 Typical Application of the 2RMLG08 Test Block and 2RMLB-R8 Test Plug Figure 3.1/4 Typical Application of the 2RMLG09 Test Block and 2RMLB-R9 Test Plug 8 Digital Grid ⋅ Reyrolle Test Block (7XG222) Catalog ⋅ Siemens Protection Device
Abrir o catálogo na página 8
Technical Documentation Dimension Drawings Dimension Drawings This section displays the different dimensional views of a Test Block. Figure 3.2/1 Panel Cut-out View Figure 3.2/2 Side View (Vertical) Top View (Horizontal) Digital Grid ⋅ Reyrolle Test Block (7XG222) Catalog ⋅ Siemens Protection Devices
Abrir o catálogo na página 9
Technical Documentation Dimension Drawings Figure 3.2/3 Front View NOTE The ∅3.6 holes are for M4 thread forming (trilobular) screws. These are supplied as standard and are suitable for use in ferrous/aluminum panels 1.6 mm thick and above. For other panels, holes to be M4 clearance (typically ∅4.5) and relays mounted using M4 machine screws, nuts and lockwashers (supplied in panel fixing kit). 10 Digital Grid ⋅ Reyrolle Test Block (7XG222) Catalog ⋅ Siemens Protection De
Abrir o catálogo na página 10
Technical Data Indication of Conformity This product complies with the directive of the Council of the European Communities on the harmonization of the laws of the Member States relating to electromagnetic compatibility (EMC Directive 2014/30/EU) and concerning electrical equipment for use within specified voltage limits (Low Voltage Directive 2014/35/EU) as well as restriction on usage of hazardous substances in electrical and electronic equipment (RoHS Directive 2011/65/EU). This conformity has been proved by tests conducted by Siemens AG in accordance of the Council Directive in...
Abrir o catálogo na página 11
Damp heat test, steady state 56 days at 93 % RH and +40 °C Enclosure Protection (2RMLG only) IEC 60529 IP50 (dust protected) 12 Digital Grid ■ Reyrolle Test Block (7XG222) Catalog ■ Siemens Protection Devices
Abrir o catálogo na página 12
Product Description Order Number Digital Grid ■ Reyrolle Test Block (7XG222) Catalog ■ Siemens Protection Devices 13
Abrir o catálogo na página 13
14 Digital Grid ■ Reyrolle Test Block (7XG222) Catalog ■ Siemens Protection Devices
Abrir o catálogo na página 14
Indication of conformity This product complies with the directive of the Council of the European Communities on harmonization of the laws of the Member States relating to electromagnetic compatibility (EMC Council Directive 2004/108/EC) and concerning electrical equipment for use within specified voltage limits (Low Voltage Directive 2006/95/EC). This conformity has been proved by tests performed according to the Council Directive in accordance with the generic standards EN 61000-6-2 and EN 61000-64 (for EMC directive) and with the standard EN 60255-27 (for Low Voltage Directive) by Siemens...
Abrir o catálogo na página 15
Published by and copyright © 2019 Siemens Protection Devices P.O. Box 8 North Farm Road Hebburn Tyne & Wear NE31 1TZ United Kingdom Phone: +44 (0)191 401 7901 Fax: +44 (0)191 401 5575 E-mail: marketing.spdl.gb@siemens.com Subject to changes and errors. The information given in this document only contains general descriptions and / or performance features which may not always specifically reflect those described or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the...
Abrir o catálogo na página 16Todos os catálogos e folhetos técnicos SIEMENS Energy automation and smart grid
-
7SR5 Platform
86 Páginas
-
Reyrolle 7SR54
2 Páginas
-
Reyrolle 7SR51
2 Páginas
-
SICAM Q100
2 Páginas
-
Reyrolle 7SR17 Rho Motor Protection
2 Páginas
-
7SR17 Rho Motor Protection Relay
20 Páginas
-
7SR105 – Rho Motor protection relay
2 Páginas
-
7SR158 Argus Voltage and Frequency Relay
16 Páginas
-
7SR21 & 7SR22 Argus
2 Páginas
-
SIPROTEC 7UM85 Generator protection
2 Páginas
-
SIPROTEC 7SK85 Motor Protection
2 Páginas
-
SIPROTEC 7SK82 Motor Protection
2 Páginas
-
SIPROTEC 7SA87
2 Páginas
-
SIPROTEC 7SA86
2 Páginas
-
SIPROTEC 7SA82
2 Páginas
-
SICAM A8000 Series
11 Páginas
-
SICAM Power Quality and Measurement
42 Páginas
-
Catalog Reyrolle 7XG222 · Edition 1
16 Páginas
-
SICAM Substation Automation
190 Páginas
-
Reyrolle Product Catalogue
346 Páginas
-
Reyrolle 5 Platform
52 Páginas
-
SIPROTEC Compact
210 Páginas
-
SICAM - Substation Automation and RTUs Ed 2
198 Páginas
-
Catalog SICAM CMIC
8 Páginas
-
7SC80 Brochure
8 Páginas
-
Catalog - Bay Controller
32 Páginas