
Reyrolle 7SR5 Platform Protecting Grids With Confidence Catalog Reyrolle 7SR5 · Edition 4.0
1 /
72Páginas
Excertos do catálogo

Device manuals Each device manual describes the functions and applications of a specific Reyrolle device. The printed manual for the device has the same informational structure. Hardware manual The hardware manual describes the hardware building blocks and device combinations of the Reyrolle device family. Operating manual The operating manual describes the basic principles and procedures for operating and installing the devices of the Reyrolle range. Communication protocol manual The communication protocol manual contains a description of the protocols for communication within the Reyrolle...
Abrir o catálogo na página 2
Digital Grid Reyrolle 7SR5 Platform Catalog Catalog Reyrolle 5 - Edition 4.0 Devices and Application Device Types Relay Selection Guide Application Examples Overcurrent Protection Transformer Differential Protection Motor Protection System Protection Monitoring Data Storage Communication Hardware Construction Technical Documentation Connection Diagrams Dimension drawings Technical data Ordering Information Digital Grid ■ Reyrolle 7SR5 Platform Catalog ■ Siemens Protection Devices 3
Abrir o catálogo na página 3
Reyrolle - Solutions for Distribution Grids First reactance & Reyrolle founded in impedance the UK measuring relays ARGUS product line introduced IEC 61850 is launched on Launch of 7SR157, Reyrolle 7SR158 Argus, and products 7SR191 Capa relays Launch of 7SR45 and 7SR10 Argus relays acquisition of impedance relay VA TECH is launched First current First transformer differential differential protection 'Merz- protection using Price', developed at second harmonic Hebburn bias (Duobias) IEC 61850 introduced Launch of onto the 7SR11 & 12 7SR18 Solkor relay Argus relay Reyrolle digital protection...
Abrir o catálogo na página 4
Devices and Application Device Types Digital Grid ⋅ Reyrolle 7SR5 Platform Catalog ⋅ Siemens Protection Devices
Abrir o catálogo na página 5
Main function Overcurrent and Feeder Protection 6 Digital Grid ■ Reyrolle 7SR5 Platform Catalog ■ Siemens Protection Devices
Abrir o catálogo na página 6
Relay Selection Guide CT supervision – current reference CT supervision – voltage reference Directional overcurrent – phase Directional earth fault – measured Directional Intermittent Earth Fault Directional sensitive earth fault – measured Directional earth fault – calculated Close-circuit supervision Trip-circuit supervision Voltage vector shift Automatic reclosing Backspin monitor Backspin monitor – voltage reference Inrush current detection Overfluxing detection – 5th harmonic Frequency protection – "df/dt" Restricted earth fault protection – highimpedance Restricted earth fault...
Abrir o catálogo na página 8
Devices and Application Application Examples – Medium Voltage Medium-Voltage Applications for all System Grounding Types [dw_Medium-voltage appl for all sys ground typ, 3, en_US] Figure 2.3/1 Medium-Voltage Applications for all System Grounding Types • Reliable detection of transients and static ground faults • Cost saving due to integrated autoreclose function • Directional and non-directional protection and control functions 10 Digital Grid ⋅ Reyrolle 7SR5 Platform Catalog ⋅ Siemens Protectio
Abrir o catálogo na página 10
Devices and Application Application Examples – Transformer Protection Two-Winding Transformer [dw_Two-winding transformer, 2, en_US] • Clear assignment of the functions to the primary element • Reduced investment • Simple parameterization • Reduced wiring and faster commissioning Protection and Backup Protection Solution for 3-Winding Transformers [dw_Protection and backup protection, 2, en_US] Figure 2.3/3 Protection and Backup Protection Solution for 3-Winding Transformers • Protection and backup protection concept • Increased availability Digital Grid ⋅ Reyrolle 7SR5 Platform Catalog ⋅...
Abrir o catálogo na página 11
Devices and Application Application Examples – Motor Protection Motor Protection Induction Motor: Protection and Control Figure 2.3/4 Induction Motor: Protection and Control • Reduced investment due to protection and control in one device • Thermal motor protection functions for reliable motor monitoring • Thermal motor protection functions with direct connection of temperature sensors 12 Digital Grid ⋅ Reyrolle 7SR5 Platform Catalog ⋅ Siemens Protectio
Abrir o catálogo na página 12
Description The Reyrolle 5 is designed for the electricity networks of the future with enhanced communications and cyber security while maintaining a user-friendly interface and easy product management. The Reyrolle 7SR51 overcurrent device includes a wide range of protection functions and IEC 61850 Ethernet communications as standard. To further minimize the product variants the power supply and the binary inputs cover the full operating range with configurable binary input thresholds. The large LCD, tactile pushbuttons and programmable LEDs provide a user-friendly product interface and...
Abrir o catálogo na página 13
Devices and Application Overcurrent Protection – Reyrolle 7SR51 Additional Functionality – Devices with VT Inputs • 21FL Fault locator • 21LB Load blinder • 25 Synchrocheck – synchronizing function • 27/27Vx Undervoltage protection • 32 Power protection • 47 Sequence overvoltage protection • 51V Voltage dependent overcurrent – phase • 55 Power factor • 59/59Vx Overvoltage protection • 59N Neutral voltage displacement • 60VTS VT supervision • 67/67G/67GI/67GS/67N Directional – phase/earth fault • 78VS Voltage vector shift • 81 Frequency protection – "f>" or "f<" • 81R Frequency protection –...
Abrir o catálogo na página 14
Figure 2.4/3 Function Diagram: 7SR5121 DOC/DEF Protection Digital Grid ■ Reyrolle 7SR5 Platform Catalog ■ Siemens Pr
Abrir o catálogo na página 15
5 An external interface unit is required. 6 Re
Abrir o catálogo na página 16
Table 2.4/1 Reyrolle 7SR51 - Functions and Application Templates
Abrir o catálogo na página 17
Devices and ApplicationOvercurrent Protection - Reyrolle 7SR51 Standard Variants Standard Variants for 7SR511 3/8, 8 BI, 6 BO, 4 I Housing width 3/8 x 19" (size 6), housing height 4U 8 binary inputs 6 binary outputs (1 break, 2 changeover, 3 make) 4 current transformer inputs Communication: USB, RS485, 2 x Ethernet 3/8, 13 BI, 8 BO, 4 I Housing width 3/8 x 19" (size 6), housing height 4U 13 binary inputs 8 binary outputs (1 break, 2 changeover, 5 make) 4 current transformer inputs Communication: USB, RS485, 2 x Ethernet 3/8, 13 BI, 11 BO (inc. 3 HSBO), 4 I, 3 AFD Housing width 3/8 x 19"...
Abrir o catálogo na página 18Todos os catálogos e folhetos técnicos SIEMENS Energy automation and smart grid
-
7SR5 Platform
86 Páginas
-
Reyrolle 7SR54
2 Páginas
-
Reyrolle 7SR51
2 Páginas
-
SICAM Q100
2 Páginas
-
Reyrolle 7SR17 Rho Motor Protection
2 Páginas
-
7SR17 Rho Motor Protection Relay
20 Páginas
-
7SR105 – Rho Motor protection relay
2 Páginas
-
7SR158 Argus Voltage and Frequency Relay
16 Páginas
-
7SR21 & 7SR22 Argus
2 Páginas
-
SIPROTEC 7UM85 Generator protection
2 Páginas
-
SIPROTEC 7SK85 Motor Protection
2 Páginas
-
SIPROTEC 7SK82 Motor Protection
2 Páginas
-
SIPROTEC 7SA87
2 Páginas
-
SIPROTEC 7SA86
2 Páginas
-
SIPROTEC 7SA82
2 Páginas
-
SICAM A8000 Series
11 Páginas
-
SICAM Power Quality and Measurement
42 Páginas
-
Catalog Reyrolle 7XG222 · Edition 1
16 Páginas
-
SICAM Substation Automation
190 Páginas
-
Reyrolle Product Catalogue
346 Páginas
-
Reyrolle 5 Platform
52 Páginas
-
SIPROTEC Compact
210 Páginas
-
SICAM - Substation Automation and RTUs Ed 2
198 Páginas
-
Catalog SICAM CMIC
8 Páginas
-
7SC80 Brochure
8 Páginas
-
Catalog - Bay Controller
32 Páginas