Excertos do catálogo

Intended purpose The GM32 gas analyzer serves for continuous measurement of gas concentrations of SO2, NO, NO2 and NH3 as well as the reference values of temperature and pressure in industrial plants. As in-situ measuring device, the GM32 determines the measured values directly in the gas carrying duct from the measuring gas spectrum. Versions The GM32 provides simultaneous multicomponent measurement (combinations of measuring components) as well as single-component measurement. The following measuring probes are available for optimized adaptation of the measuring device to the measuring point: • GMP measuring probe with open measuring aperture for use with high dust loads in the measuring gas • GPP measuring probe with gas-permeable ceramic filter in the measuring gap. The GM32 gas analyzer comprises the following components: • Sender/receiver unit • Measuring probe, GMP or GPP • Connection unit • Purge air unit (for GMP probe) • Mounting flange • SCU operating unit (option) Simultaneous or individual measurement of SO2, NO, NO2 and NH3 as well as temperature and pressure DATA SHEET GM32 Measuring Probe Version certified
Abrir o catálogo na página 1
2 GM32 | SICK Project planning and preparation Project planning of the measuring device is very important to ensure unrestricted function and efficient start-up. The main requirements and preparations at the installation site as well as a wiring example with connection options are described in the following. Requirements at the installation site • Determination of measuring point – Provide for an unhindered inlet and outlet paths. – Provide for calibration openings at easily accessible places. Ensure that the measuring device and the calibration probe do not influence each other; provide...
Abrir o catálogo na página 2
GM32 | SICK 3 Wiring and connections The Figure below shows a wiring example with the connections of the GM32 components. See the Operating Instructions for details for the concrete connection assignments, e.g. from the connection unit. Wiring example: Measuring probe version Measuring probe Sender/receiver unit (SR) Purge air unit SLV 4 (for GMP measuring probe) Connection unit (AE) For wiring and technical data, see Data Sheet SLV4 (3) (5) (4) (6) (3) connection: Purge air attachement (4) connection: Power supply (5) connection: CAN cable (6) connection: PC/network SOPAS ET (3) (1) (4)...
Abrir o catálogo na página 3
4 GM32 | SICK Technical Data Technical Data GM32 Measuring Parameters Measuring principle Differential Optical Absorption Spectroscopy (DOAS) Measured components SO2, NO, NO2, NH3 thereof TÜV-tested for suitability: SO2, NO Available measuring ranges (calibration ranges) Min. Max. TÜV tested for suitability at T = 140 °C and active measuring path = 1.25 m SO2: 0 … 40 mg/m3Operation•m 0 … 20.000 mg/m3Operation•m 0 … 75 mg/m3Standard NO: 0 … 50 mg/m3Operation•m 0 … 2.500 mg/m3Operation•m 0 … 70 mg/m3Standard NO2: 0 … 100 mg/m3Operation•m 0 … 2.000 mg/m3Operation•m – NH3: 0 … 25...
Abrir o catálogo na página 4
GM32 | SICK 5 General information System components • Sender/receiver unit • Measuring probe with purge air fixture – Type GMP with open measuring aperture or – Type GPP, gas diffusion probe • Flange (option) • Purge air unit with GMP probe: See Operating Instructions SLV4 • Connction unit • SCU operating unit: See Operating Instructions SCU Dimensions (L x W x H) (see Dimensions) • Sender/receiver unit (including purge air fixture): 586 x 315 x 580 mm • Measuring probes: See ¨ P. 7, Fig. 3, ¨ P. 7, Fig. 4 • Connection unit: 450 x 400 mm, ¨ P. 8, Fig. 6 • Purge air unit SLV4: 550 x 550 x...
Abrir o catálogo na página 5
6 GM32 | SICK Dimensions Fig. 2 GM32 sender/receiver unit The housing of the sender/receiver unit can be swiveled open to the left or right of the device flange (max. 180°/105°).
Abrir o catálogo na página 6
Fig. 3 GM32 measuring probe, type GMP – open measuring probe Fig. 4 GM32 measuring probe, type GPP – gas diffusion probe
Abrir o catálogo na página 7
SICK MAIHAK GmbH | Germany Nimburger Str. 11 | D-79276 Reute | www.sick.com Phone +49 7641 469-0 | Fax +49 7641 469-1149 | info.pa@sick.de 8012710/2009-02• Printed in Germany • Subject to modifications • Specified product characteristics and technical data do not serve as guarantee declarations Fig. 5 Mounting flange Fig. 6 Connection unit ø 240 ø 178 ø 125 ø 133 14 240/500 8 18 45° 200 M20
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos SICK
-
W4F en
17 Páginas
-
SLG-2 en
14 Páginas
-
IMS en
12 Páginas
-
IO-Link Supplement
5 Páginas
-
T-Easic FTS
56 Páginas
-
FLUID SENSORS Overview of the Products
16 Páginas
-
T-Easic® FTS
12 Páginas
-
T-Easic® FTS
4 Páginas
-
FLOWSIC100 PROCESS
134 Páginas
-
SPEETEC 1D
6 Páginas
-
SPEETEC
2 Páginas
-
midiCam
5 Páginas
-
W4-3 PTFE
4 Páginas
-
Photoelectric laser sensors
20 Páginas
-
SMART SENSORS
48 Páginas
-
Photoelectric sensors_2019
20 Páginas
-
AHS/AHM36 SSI Inox
29 Páginas
-
STEEL INDUSTRY
8 Páginas
-
MultiPulse
37 Páginas
-
Safe Robotics Area Protection
32 Páginas
-
ENCODERS AND INCLINATION SENSORS
40 Páginas
-
EDS/EDM35
12 Páginas
-
G2F Photoelectric sensors
20 Páginas
-
TR110 Lock
20 Páginas
-
24-hour helpdesk
8 Páginas
-
OPTO-ELECTRONIC PROTECTIVE DEVICES
32 Páginas
-
outdoorScan3
20 Páginas
-
EnforceKey Single Door
84 Páginas
-
WTB16 Bluetooth®
135 Páginas
-
LD-LRS Laser Measurement System
6 Páginas
-
PET Pressure transmitter
44 Páginas
-
LFV 310/330
48 Páginas
-
WT18X-3P930
2 Páginas
-
T-Verteiler mit Taster
8 Páginas
-
CLV63x, CLV64x, CLV65x Bar code scanners
80 Páginas
-
Proximity Sensors
20 Páginas
-
Registration Sensors
24 Páginas
-
FLG Standard automation light grids
12 Páginas
-
Advanced Automation Light Grids
92 Páginas
-
QAL3 Master
4 Páginas
-
MCS100FT FTIR Analysis System
12 Páginas
-
MCS100E HW/CD/PD Multicomponent Analysis
16 Páginas
-
GM960 Boiler Wall Monitor
8 Páginas
-
Dust measuring devices
171 Páginas
-
Automation Light Grids
228 Páginas
-
Maritime Emissions Monitoring
2 Páginas
-
Raw Gas Measurement
2 Páginas
-
TranspaTect product information
16 Páginas
-
GR18 product information
56 Páginas
-
Top Products from SICK
486 Páginas
-
SICK Essentials
118 Páginas
-
Magnetic Cylinder Sensors
164 Páginas
-
Presence Detection
170 Páginas
-
Industrial Safety Systems
1054 Páginas
-
Fluid Sensors
174 Páginas
-
Encoders
388 Páginas
-
Distance Sensors
404 Páginas
-
Detection and Ranging Solutions
124 Páginas
-
Identification Solutions
308 Páginas
-
Zone control
5 Páginas
-
fiber-optic sensors
5 Páginas
-
PACKAGING2009/10
20 Páginas
-
System solutions VMS410/510 / VMS410
4 Páginas
-
Inductive proximity sensors
5 Páginas
Catálogos arquivados
-
Photoelectric sensors_2012
5 Páginas
-
safety laser scanners
5 Páginas
-
3D cameras
6 Páginas
-
Miniature photoelectric sensors
5 Páginas
-
MCS300P Superior in front
4 Páginas
-
MKAS Compact Analysis system
2 Páginas
-
FLOWSIC 600
4 Páginas
-
W9-2 Small photoelectric sensors
7 Páginas
-
Product overview Industrial Sensors
100 Páginas
-
News Factory Automation
8 Páginas