Grupo: Spectris
Excertos do catálogo

Product overview Intrinsically safe analyzer measures O2 Unrivalled performance Uses industry-leading patented Paramagnetic technology for stable, non- depleting measurement Process control Safety SENSING TECHNOLOGY Manufactured by Servomex over 70 years’ experience innovating and pioneering gas analysis, and thousands of units used in the field every year Flexible Intrinsically Safe (i.s.) design permits use in any hazard rated location including Zone 0/Division 1 Low cost of ownership Uses a non-depleting sensor technology that reduces ongoing maintenance costs Advanced Li-Ion rechargeable batteries as standard (up to 18 hour run time) Benchmark compliance IECEx/ATEX/UKEX for Zone 0, and FM (USA & Canada) Division 1 Gas analysis for O2 Pumped or non-pumped (AFCD pressure driven) gas sampling IP65 rating Easy to use Intuitive, engineer-friendly interface and icons Key applications Process monitoring Inerting applications Stores up to 200 measurement points for subsequent review Ergonomic design with carry strap Controlled atmosphere monitoring Hazardous area combustion optimization For more information visit servomex.com/cont
Abrir o catálogo na página 1
Micro i.s. 5100 Enhanced safety for the most dangerous locations When you work in environments where potentially explosive atmospheres may be present, you need the most robust analytical solutions that enhance safety and provide efficient, engineer-friendly gas measurements. In applications like catalytic regeneration, decoke cycle, combustion optimization and hazardous area process monitoring, i.s. certified solutions help reduce costs and improve efficiency. No matter what your application monitoring requirements are, you’ll want a device that offers feature-rich performance, long battery...
Abrir o catálogo na página 2
Technical data sheet Oxygen (O2) Industrial accurancy sensor Oxygen (O2) High accuracy sensor Magnetodynamic paramagnetic sensor Technology Performance 0-21% O2 (0-100% O2 * in safe area locations only) Measurement range Decimal places displayed Linearity error Repeatability error Intrinsic error (accuracy) Zero drift per week Sample flow variations Temperature coefficient Zero Span Tilt effect ±0.15% O2 per 15º of tilt Directly proportional to ambient barometric pressure Pressure effect Power cycle Signal outputs Alarms BATTERY (rechargeable lithium ion) Two user configurable concentration...
Abrir o catálogo na página 3
Operating environment Temperature Relative humidity Allow 1 hour to meet performance specifications Operating altitude range Ambient pressure Sample conditions Sample gas Clean, dry at ambient temperature and free from particulates <2µm (conditioning accessories are available to prepare sample where required) Sample inlet connection 5mm OD stub with QuickConnect barb fitting for 5mm (1/4”) ID tube Sample outlet connection 5mm OD stub (sample and bypass) Optional connector QuickConnect fitting to an 1⁄8” NPT threaded fitting Maximum inlet pressure 5110 pumped (internal sample pump) 5111 AFCD...
Abrir o catálogo na página 4
Compliance Hazardous area approvals ATEX European UKEX Great Britain IECEx International This product is in compliance with the EMC Directive, the RoHS Directive, and all other applicable directives. Electrical safety Permitted oxygen measurement and sample pressure ranges for hazardous area location use Outside atmosphere (external environment) Zone 1 or Zone 0 Certified Location ≤21% oxygen 11.6 - 16.0psia (80 - 110kPa abs) Portable type Maximum permitted Oxygen level Sample pressure
Abrir o catálogo na página 5
Options - 5110 (internal pump) Configuration 5110 Micro i.s Variants We have two pre-configured 5110 (internal pump) builds that cover the most common chosen option configurations to enable a quick turnaround from specification to delivery. The pre-configured standard variant 1 base level configuration, including the Industrial Accuracy oxygen measurement, for general oxygen measurement requirements. The pre-configured standard variant 2 base level configuration, including the High Accuracy oxygen measurement, for general oxygen measurement requirements. Other analyzer configurations not...
Abrir o catálogo na página 6
Options - 5111 (AFCD pressure driven) Configuration 5111 Micro i.s Variants We have two pre-configured 5111 (AFCD) builds that cover the most common chosen option configurations to enable a quick turnaround from specification to delivery. The pre-configured standard variant 1 base level configuration, including the Industrial Accuracy oxygen measurement, for general oxygen measurement requirements. The pre-configured standard variant 2 base level configuration, including the High Accuracy oxygen measurement, for general oxygen measurement requirements. Other analyzer configurations not...
Abrir o catálogo na página 7
Dimensional drawings Dimensions shown in millimetres (dimensions in brackets are in inches)
Abrir o catálogo na página 8
We’re ready to help Whatever your gas analysis requirements, wherever you are. These analyzers are not intended for any form of use on humans and are not medical devices as described in the Medical Devices legislation or regulation. Please note: Whilst every effort has been made to ensure accuracy, no responsibility can be accepted for errors and omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This document is not intended to form the basis of a contract. Servomex has a...
Abrir o catálogo na página 9Todos os catálogos e folhetos técnicos SERVOMEX
-
Service Guide Issue 4
13 Páginas
-
Product Guide Issue 9
15 Páginas
-
Gas Guide Issue 5
74 Páginas
-
SERVOTOUGH OxyExact 2200
16 Páginas
-
SERVOPRO 4900 Multigas Product Brochure
10 Páginas
-
SERVOPRO Chroma Product Brochure
8 Páginas
-
SERVOPRO FID Product Brochure
6 Páginas
-
SERVOPRO NanoChrome Product Brochure
6 Páginas
-
SERVOPRO Plasma Product Brochure
6 Páginas
-
SERVOPRO 4900 Multigas
10 Páginas
-
SERVOPRO PureGas
4 Páginas
-
SERVOTOUGH Oxy 1900 Product Brochure
9 Páginas
-
SERVOTOUGH Laser 3 Plus Combustion
7 Páginas
-
SERVOTOUGH Laser 3 Plus Process
7 Páginas
-
SERVOPRO DF-550E Product Brochure
6 Páginas
-
Servomex Service Prodiuct Portfolio
2 Páginas
-
Servomex Product Portfolio
2 Páginas
-
Expert Solutions Issue 42 TDL technology
11 Páginas
-
SERVOPRO NanoTrace DF-760E/760E Ultra
112 Páginas
-
DF560E Operator Manual
144 Páginas
-
DF-745 Operator Manual
112 Páginas
-
ES 39 Sustainability
11 Páginas
-
ES 38 Korea Special
19 Páginas
-
ES 37 Clean Air part II
11 Páginas
-
ES 36 Purity & Specialty
11 Páginas
-
ES 35 Photometric Analysis
11 Páginas
-
ES 34 70th Anniversary
15 Páginas
-
ES Magazine Issue 32 China Special
13 Páginas
-
ES 31 Industrial Process & Emissions
11 Páginas
-
ES30 Air Separation Units
11 Páginas
-
ES 29 Clean Air
11 Páginas
-
ES 28 Gas Analysis Applications
11 Páginas
-
Sensing Technologies
13 Páginas
-
SERVOPRO NOx Operators Manual PN 221195 r0
224 Páginas
-
SERVOPRO HFID Operators Manual PN 221196 r0
211 Páginas
-
SERVOPRO FID Operator Manual 01000001A_5
67 Páginas
-
SERVOPRO Chroma Operator Manual 04400001A_6
139 Páginas
-
DF760E Operator Manual
182 Páginas
-
DF750 Operator Manual
112 Páginas
-
DF745SGMax Operator Manual
90 Páginas
-
DF-740 Operator Manual
87 Páginas
-
DF-730 Operator Manual
82 Páginas
-
DF560E Operator Manual 082616
146 Páginas
-
DF550E Operator Manual 082616
134 Páginas
Catálogos arquivados
-
SERVOFLEX MiniMP 5200
7 Páginas
-
Servomex Gas Guide - Issue 4
76 Páginas
-
Servomex Product Guide - Issue 8
15 Páginas
-
Servomex Service Guide - Issue 3
13 Páginas
-
SERVOTOUGH SpectraScan 2400
2 Páginas
-
SERVOTOUGH H2 Scan
2 Páginas
-
SERVOPRO NOx
4 Páginas
-
SERVOPRO HFID
4 Páginas
-
Servomex Product Portfolio 2023
2 Páginas
-
Servomex Service Portfolio
2 Páginas
-
Servomex GAS GUIDE issue 3
77 Páginas
-
Servomex Service Guide Issue 2
11 Páginas
-
Servomex Product Guide Issue 7
13 Páginas
-
Servomex Gas Guide 2022
65 Páginas