
Grupo: Spectris
Excertos do catálogo

NanoTrace Moisture Analyzer DF-730 OPERATOR MANUAL
Abrir o catálogo na página 1
Copyright 2009 by Servomex No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, or by any means including electronic, mechanical, photocopying, recording or otherwise without prior written permission of Servomex. NanoTrace Moisture Analyzer is a trademark of Servomex. VCR is a registered trademark of the Cajon Company
Abrir o catálogo na página 2
DF-730 Operator Manual Manual Version 120613 Your NanoTrace Moisture Analyzer has been designed, manufactured and is supported under ISO-9001 controls, thus helping to insure the highest possible standards of quality. Every analyzer that Servomex manufactures is tested and operated on a variety of gas concentrations to insure that it functions properly when you receive it. The certificate of calibration assures your analyzer has been calibrated on gases that are traceable to NIST standards. With proper maintenance, your analyzer should remain calibrated for years. For a fast and successful...
Abrir o catálogo na página 3
Read Me First… Unpacking Procedure Follow the procedure below to unpack your NanoTrace Moisture Analyzer 1. Examine the condition of the packaging and its contents. If any damage is apparent, immediately notify the carrier and Servomex. Do not proceed with the installation. 2. Check the contents against the packing slip to make sure the shipment is complete. Unattached equipment may be shipped with the analyzer in supplemental packaging. Shortages should be reported to Servomex immediately. 3. All NanoTrace Moisture Analyzers are shipped with the following: Item Part Number Power cord with...
Abrir o catálogo na página 5
Thank You Thank you for selecting the NanoTrace Moisture Analyzer. Servomex designs, manufactures, exhaustively tests, and supports every analyzer under the tightest quality controls. You should expect every Servomex analyzer to arrive in perfect working order and, with good maintenance, provide years of trouble-free service. Please call your nearest Servomex Business Center if you need assistance.
Abrir o catálogo na página 6
3 Cautions There are a number of warnings and cautions that must be observed to avoid damage to the analyzer as well to insure the safety of its users. The analyzer must be operated in a manner specified in this manual. Servomex cannot be responsible for direct or consequential damages that result from installing or operating the analyzer in a manner not described in this manual. Importantly, the analyzer has been designed for use with inert, non-toxic, non-combustible sample gases only. Servomex cannot be responsible for direct or consequential damages that result from using the analyzer...
Abrir o catálogo na página 13
CAUTION Do not setup or operate this analyzer without a complete understanding of the instructions in this manual. Do not connect this Analyzer to a power source until all signal and plumbing connections are made. CAUTION This analyzer must be operated in a manner consistent with its intended use and as specified in this manual. EMI DISCLAIMER This Analyzer generates and uses small amounts of radio frequency energy. There is no guarantee that interference to radio or television signals will not occur in a particular installation. If interference is experienced, turn-off the analyzer. If the...
Abrir o catálogo na página 14
4 Specifications All specifications assume an HCL background. 4.1 Moisture Lowest Detection Level (LDL): 10 ppb @ Constant Conditions Resolution: Analytical (Smallest Detectable Change): 2 ppb Display: 10 ppt Accuracy: Greater of ±5% of reading or ± 0.5 ppb @ Constant Conditions Speed of Response: Typically 15 minutes to reach 90 percent of an upward step change Upset Recovery Time: Typically less than 5 minutes from a high ppb upset to within 10 ppb of the previously stable reading. Range: 0-10 ppm Background Gas Compatibility: HCL, H2, and Nitrogen gases Return Pressure: 70 Torr 4.2...
Abrir o catálogo na página 15
Audible/Visual Alarm Status Indicators: Four Moisture levels, Temperature, Moisture cell Diagnostic, Zero Verification or Calibration in Process, Moisture Analyzer off-line, Analog output freeze during calibration. Alarm Relays: Four non-latching, independently assignable to moisture alarms or to moisture calibration-in-process indicator. SPDT contacts rated at 1 Amp @ 30 VDC. Fail safe action upon loss of power to alarm condition. Not designed to switch AC power. Storage Temperature: Not to exceed 50° C (122° F) Construction: NEMA 1, 19 inch rack mount Dimensions: 19 inch (48.3cm) wide x...
Abrir o catálogo na página 16
Figure 1: Overall View
Abrir o catálogo na página 17
5 Installation, Start Up and Shut Down Installation of the analyzer requires the following steps be followed: Connecting the sample gas line to the inlet fitting Mounting the vacuum pump Connecting the line from the sample outlet to the needle control valve and vacuum pump Connecting the pneumatic pressure service to the pneumatic inlet fitting Making the power connection to the vacuum pump Making the power connection to the analyzer POWER SWITCH Figure 2: Major Internal Components Installation, Start Up and Shut
Abrir o catálogo na página 19
5.1 Analyzer Installation 5.1.1 Gas Connections 5.1.1.1 Sample Gas Inlet Connection Sample gas is connected to the analyzer via a ¼ inch male swivel VCR fitting at the rear of the instrument as shown in Figure 3. Sample pressure of 9-15 psig is required and is regulated by a customer supplied regulator. Use a VCR filter gasket (supplied) to protect the gas delivery system from any particulate matter. Pre-purge the line by connecting to the analyzer (with a new VCR filter gasket) only finger tight and flowing gas for 15 minutes. When power is applied to the analyzer, the internal gas control...
Abrir o catálogo na página 20
PROCESS INLET PROCESS OUTLET Figure 3: Rear Panel Gas Connections and Controls Ø.28 [Ø7.14] 4 PL MOUNTING FOR BOTTOM OF BRACKET Ø.28[Ø7.14] 4 PL MOUNTING FOR REAR OF BRACKET Ø.28 [Ø7.14] 4 PL MOUNTING FOR LEFT OR RIGHT SIDE OF BRACKET Figure 4: Vacuum Pump Mounting Dimensions Installation, Start Up and Shut Down
Abrir o catálogo na página 21
Figure 5: Vacuum Pump Dimensions 5.1.2 Electrical Connections Open the door and locate the power switch in the center of the upper rail. Be sure it is in the OFF position. Plug the supplied line cord (110VAC only) into the receptacle at the back of the analyzer. Verify the operating voltage is proper according to the label on the rear and connect the line cord to the power source. See Figure 6 Plug the vacuum pump power cord into a power receptacle capable of supplying a minimum of 5A at the appropriate voltage as indicated on the pump label. CAUTION Be sure the pump outlet is at...
Abrir o catálogo na página 22Todos os catálogos e folhetos técnicos SERVOMEX
-
Service Guide Issue 4
13 Páginas
-
Product Guide Issue 9
15 Páginas
-
Gas Guide Issue 5
74 Páginas
-
SERVOTOUGH OxyExact 2200
16 Páginas
-
SERVOPRO 4900 Multigas Product Brochure
10 Páginas
-
SERVOPRO Chroma Product Brochure
8 Páginas
-
SERVOPRO FID Product Brochure
6 Páginas
-
SERVOPRO NanoChrome Product Brochure
6 Páginas
-
SERVOPRO Plasma Product Brochure
6 Páginas
-
SERVOPRO 4900 Multigas
10 Páginas
-
SERVOPRO PureGas
4 Páginas
-
SERVOTOUGH Oxy 1900 Product Brochure
9 Páginas
-
SERVOTOUGH Laser 3 Plus Combustion
7 Páginas
-
SERVOTOUGH Laser 3 Plus Process
7 Páginas
-
SERVOPRO DF-550E Product Brochure
6 Páginas
-
Servomex Service Prodiuct Portfolio
2 Páginas
-
Servomex Product Portfolio
2 Páginas
-
Expert Solutions Issue 42 TDL technology
11 Páginas
-
SERVOPRO NanoTrace DF-760E/760E Ultra
112 Páginas
-
DF560E Operator Manual
144 Páginas
-
DF-745 Operator Manual
112 Páginas
-
ES 39 Sustainability
11 Páginas
-
ES 38 Korea Special
19 Páginas
-
ES 37 Clean Air part II
11 Páginas
-
ES 36 Purity & Specialty
11 Páginas
-
ES 35 Photometric Analysis
11 Páginas
-
ES 34 70th Anniversary
15 Páginas
-
ES Magazine Issue 32 China Special
13 Páginas
-
ES 31 Industrial Process & Emissions
11 Páginas
-
ES30 Air Separation Units
11 Páginas
-
ES 29 Clean Air
11 Páginas
-
ES 28 Gas Analysis Applications
11 Páginas
-
Sensing Technologies
13 Páginas
-
SERVOPRO NOx Operators Manual PN 221195 r0
224 Páginas
-
SERVOPRO HFID Operators Manual PN 221196 r0
211 Páginas
-
SERVOPRO FID Operator Manual 01000001A_5
67 Páginas
-
SERVOPRO Chroma Operator Manual 04400001A_6
139 Páginas
-
DF760E Operator Manual
182 Páginas
-
DF750 Operator Manual
112 Páginas
-
DF745SGMax Operator Manual
90 Páginas
-
DF-740 Operator Manual
87 Páginas
-
DF560E Operator Manual 082616
146 Páginas
-
DF550E Operator Manual 082616
134 Páginas
Catálogos arquivados
-
SERVOFLEX MiniMP 5200
7 Páginas
-
Servomex Gas Guide - Issue 4
76 Páginas
-
Servomex Product Guide - Issue 8
15 Páginas
-
Servomex Service Guide - Issue 3
13 Páginas
-
SERVOTOUGH SpectraScan 2400
2 Páginas
-
SERVOTOUGH H2 Scan
2 Páginas
-
SERVOPRO NOx
4 Páginas
-
SERVOPRO HFID
4 Páginas
-
Servomex Product Portfolio 2023
2 Páginas
-
Servomex Service Portfolio
2 Páginas
-
Servomex GAS GUIDE issue 3
77 Páginas
-
Servomex Service Guide Issue 2
11 Páginas
-
Servomex Product Guide Issue 7
13 Páginas
-
Servomex Gas Guide 2022
65 Páginas