UBA, UAL series
1 / 30Páginas

{{requestButtons}}

Excertos do catálogo

UBA, UAL series - 1

Linear actuators UBA Series and UAL Series

Abrir o catálogo na página 1
UBA, UAL series - 2

Linear actuators UBA Series and UAL Series 4.1 MANUFACTURING FEATURES Input drive: timing belt transmission; pulleys UNI ISO 5294:1991 in aluminium for low inertia; positive timing belts UNI ISO 5296-1:1991. Housing: designed and manufactured in monobloc form to obtain a compact body able to sustain heavy axial loads and high machining accuracy. High quality materials are used: ▪ castings in hardened aluminium alloy EN 1706 AC-AlSi10Mg T6 Ball screw: Acme screw: ▪ ISO trapezoidal thread ISO 2901 ... ISO 2904 ▪ designed and manufactured by SERVOMECH ▪ material: steel C 43 (UNI 7847) ▪ rolled...

Abrir o catálogo na página 2
UBA, UAL series - 3

Linear actuators UBA Series 4.2 TECHNICAL DATA - ball screw linear actuators UBA Series SIZE Outer tube diameter Attachment flange for IEC standard motor Max. dynamic load. Max. static load Diameter × Lead Ball Ball screw Linear travel [mm] for 1 input shaft revolution Diameter × Lead Ball Ball screw N° of circuits Dynamic load Ca Linear travel [mm] for 1 input shaft revolution Mass (actuator 100 mm stroke length, without motor, with lubricant) Extra-mass for each additional 100 mm stroke length

Abrir o catálogo na página 3
UBA, UAL series - 4

Linear actuators UAL Series 4.2 TECHNICAL DATA - acme screw linear actuators UAL Series SIZE Outer tube diameter Attachment flange for IEC standard motor Max. dynamic load Max. static load RV1 Linear travel [mm] for 1 input shaft revolution Linear travel [mm] for 1 input shaft revolution Mass (actuator 100 mm stroke length, without motor, with lubricant) Extra-mass for each additional 100 mm stroke length

Abrir o catálogo na página 4
UBA, UAL series - 5

Linear actuators UBA Series BALL SCREW LINEAR ACTUATORS UBA Series with AC 3-PHASE MOTOR PERFORMANCE with: Duty Cycle Fi = 100 % at ambient temperature 25 °C LINEAR SPEED [mm/s] MOTOR: POWER [kW] — N° of POLES SPEED [rpm] SELF-LOCKING COEFFICIENT value limited by electric motor power; ball screw lifetime L10h > 1000 hours (see diagrams on pages 33 ... 35) The total dynamic efficiency (h) of UBA Series actuators, used to determine the dynamic load is calculated as follows: h = h 1 × h2 × h 3 where: h1 = 0.95 – timing belt transmission efficiency h2 = 0.9 – ball screw - nut efficiency h3 =...

Abrir o catálogo na página 5
UBA, UAL series - 6

Linear actuators UAL Series ACME SCREW LINEAR ACTUATORS UAL Series with AC 3-PHASE MOTOR PERFORMANCE with: Duty Cycle Fi = 30 % over 10 min at ambient temperature 25 °C LINEAR SPEED [mm/s] MOTOR: POWER [kW] — N° of POLES SPEED [rpm] SELF-LOCKING COEFFICIENT value limited by electric motor power The total dynamic efficiency (h) of UAL Series actuators, used to determine the dynamic load is calculated as follows: h = h 1 × h 2 × h3 where: h1 = 0.95 – timing belt transmission efficiency h2 – acme screw-bronze nut dynamic efficiency, calculated with reference to the speed h3 = 0.9 – bearings...

Abrir o catálogo na página 6
UBA, UAL series - 7

Linear actuators UBA Series BALL SCREW LINEAR ACTUATORS UBA Series with AC 1-PHASE MOTOR PERFORMANCE with: Duty Cycle Fi = 100 % at ambient temperature 25 °C LINEAR SPEED [mm/s] MOTOR: POWER [kW] — N° of POLES SPEED [rpm] SELF-LOCKING COEFFICIENT value limited by electric motor power; ball screw lifetime L10h > 1000 hours (see diagrams on pages 33 ... 35) The total dynamic efficiency (h) of UBA Series actuators, used to determine the dynamic load is calculated as follows: h = h 1 × h2 × h 3 where: h1 = 0.95 – timing belt transmission efficiency h2 = 0.9 – ball screw - nut efficiency h3 =...

Abrir o catálogo na página 7
UBA, UAL series - 8

Linear actuators UAL Series ACME SCREW LINEAR ACTUATORS UAL Series with AC 1-PHASE MOTOR PERFORMANCE with: Duty Cycle Fi = 30 % over 10 min at ambient temperature 25 °C LINEAR SPEED [mm/s] MOTOR: POWER [kW] — N° of POLES SPEED [rpm] SELF-LOCKING COEFFICIENT value limited by electric motor power The total dynamic efficiency (h) of UAL Series actuators, used to determine the dynamic load is calculated as follows: h = h 1 × h 2 × h3 where: h1 = 0.95 – timing belt transmission efficiency h2 – acme screw-bronze nut dynamic efficiency, calculated with reference to the speed h3 = 0.9 – bearings...

Abrir o catálogo na página 8
UBA, UAL series - 9

Linear actuators UBA Series BALL SCREW LINEAR ACTUATORS UBA Series with DC MOTOR PERFORMANCE with: Duty Cycle Fi = 100 % at ambient temperature 25 °C LINEAR SPEED [mm/s] SELF-LOCKING COEFFICIENT MOTOR: POWER [kW] — N° of POLES SPEED [rpm] value limited by electric motor power; ball screw lifetime L10h > 1000 hours (see diagrams on pages 33 ... 35) The total dynamic efficiency (h) of UBA Series actuators, used to determine the dynamic load is calculated as follows: h = h 1 × h2 × h 3 where: h1 = 0.95 – timing belt transmission efficiency h2 = 0.9 – ball screw - nut efficiency h3 = 0.9 –...

Abrir o catálogo na página 9
UBA, UAL series - 10

Linear actuators UAL Series ACME SCREW LINEAR ACTUATORS UAL Series with DC MOTOR PERFORMANCE with: Duty Cycle Fi = 30 % over 10 min at ambient temperature 25 °C LINEAR SPEED [mm/s] SELF-LOCKING COEFFICIENT MOTOR: POWER [kW] — N° of POLES SPEED [rpm] value limited by electric motor power The total dynamic efficiency (h) of UAL Series actuators, used to determine the dynamic load is calculated as follows: h = h 1 × h 2 × h3 where: h1 = 0.95 – timing belt transmission efficiency h2 – acme screw-bronze nut dynamic efficiency, calculated with reference to the speed h3 = 0.9 – bearings and...

Abrir o catálogo na página 10
UBA, UAL series - 11

Linear actuators UBA Series BALL SCREW LINEAR ACTUATORS UBA Series, size 1 — 2 — 3 — 4 AC 3-phase or 1-phase MOTOR — with Magnetic Stroke Limit Switches FCM La = Lc + STROKE STROKE STANDARD HEAD with threaded bore BA 4 Lc - RETRACTED ACTUATOR length La - EXTENDED ACTUATOR length FRONT ATTACHMENTS MAGNETIC STROKE LIMIT SWITCHES FCM Dimensions L REED CONTACT NC or (NC+NO) NO 42 47 51 56 59

Abrir o catálogo na página 11
UBA, UAL series - 12

Linear actuators UBA Series BALL SCREW LINEAR ACTUATORS UBA Series, size 1 — 2 — 3 — 4 AC 3-phase or 1-phase MOTOR — with Magnetic Stroke Limit Switches FCM STANDARD STROKE LENGTHS STROKE CODE C100 C200 C300 C400 C500 C600 C700 C800 UBA 1 UBA 2 UBA 3 UBA 4 NOTE: Different stroke lengths available on request. La = Lc + STROKE For stroke lengths longer than 800 mm it is necessary to increase the guided length between push rod and outer tube to avoid axial backlash. Dimensions S2, T and Q2 shall be considered increased by 200 mm for stroke lengths up to 1500 mm. For stroke lengths longer than...

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos SERVOMECH

  1. BALL SCREW JACKS

    132 Páginas

  2. Ball Screw Jacks

    128 Páginas

  3. Bevel gearboxes

    52 Páginas

  4. TMA series

    28 Páginas

  5. CLA, CLB series

    24 Páginas

  6. Acme Screw Jacks