Excertos do catálogo

Stationary water quality monitoring with nitrate probe SPS-NO3 • • • • • Robust, low maintenance single parameter sonde (SPS) made of 1.4571 stainless steel for the measurement of nitrate (NO3- , NO3-N) Slim design (Ø 48.3 mm) for observation wells starting from 3“ diameter High measuring accuracy, drift-free, only annual verification of the calibration needed Available in different measuring ranges up to max. 0… 266 mg/L NO3Output: RS 485 (SHWP, Modbus RTU) for the connection with SEBA data logger B24_Nitratsonde_SPS_NO3_e_S1-2
Abrir o catálogo na página 1
Nitrate probe SPS-NO3 The problem: increasing nitrate pollution in natural water resources Drinking water supply in Germany and many other countries laboratory analyses indicate that concentrations peak after is largely covered by groundwater resources. But groundwater events such as heavy rain are incomplete and only identified by is increasingly polluted with nitrate. One reason is the exten- coincidence: sive practice of nitrogen fertilization in agriculture. In addition Nitrat to mineral fertilizers, substrates such as liquid manure from [mg/L] livestock farms or biogas plants are used...
Abrir o catálogo na página 2
The perfect, self-sufficient SEBA water quality station with SPS-NO3: The protective housing concept The robust aluminum protective housing „Alpha“ is impact-resistant, functional and offers sufficient space for a data logger, remote data transmission and self-sufficient energy supply. A tilting mechanism enables the operator simply to fold away the protective housing in order to easily pull-out the nitrate probe SPS-NO3 and other probes for maintenance or control purposes. The logger and data transmission concept The core of the SEBA water quality station is the low-power data logger...
Abrir o catálogo na página 3
High measurement accuracy, drift-free, minimal calibration effort: The SPS-NO3 usually needs to be checked only once a year. Low operating costs: no consumption of reagents or replacement of used electrodes. The slim design of the SPS-NO3 allows installation in 3” pipe diameters. Connectivity to SEBA data logger: A Modbus converter or a ModBus interface as factory setting enables the SPS-NO3 being connected to all SEBA data logger of the newest generation (e.g. UnilogCom, NetlogCom). Technical data Nitrate probe Metrology: Measurement principle: Optical path: Parameter: Measurement range:...
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos Seba Hydrometrie GmbH & Co. KG
-
Product folder
214 Páginas
-
ModCom
2 Páginas
-
HDA-Tablet
2 Páginas
-
SlimCom IoT LR
2 Páginas
-
LogCom/FlashCom
4 Páginas
-
UnilogCom
2 Páginas
-
SlimLogPlus
4 Páginas
-
DS (T)
2 Páginas
-
Radar Sensor Type SEBAPULS
2 Páginas
-
Software Q4
4 Páginas
-
MPS Water quality monitoring
8 Páginas
-
PS-Light-2
4 Páginas
-
LogCom-Q/UnilogCom-Q
4 Páginas
-
SlimCom
2 Páginas
-
FlowFlat
4 Páginas
-
KLL, KLL-T, KLL-Mini, TLG
4 Páginas
-
Discharge App
4 Páginas
-
HDA-Pro
2 Páginas
-
Automatic Weatherstation Type AWS
4 Páginas
-
Dipper-PT
8 Páginas
-
Dipper-PTEC
8 Páginas
-
Dipper-APT/BaroDipper
8 Páginas
-
SEBA Top Pieces
2 Páginas
-
StreamPro ADCP
4 Páginas
-
Pneutmatic Gauge PS
4 Páginas
-
Flood Control - Alarm Systems
4 Páginas
-
Rain Gauge Measurement Systems
4 Páginas
-
DischargeKeeper
4 Páginas
-
NetLogCom
8 Páginas
-
DischargeKeeper Reference Projects
8 Páginas
-
Software Hydrocenter
4 Páginas
-
Software DEMASvis
2 Páginas
-
Software DEMASole
2 Páginas
-
Software DEMASdb
2 Páginas
-
IridiumSat
2 Páginas
-
Checker-2
4 Páginas
-
Mobile bridge jib
2 Páginas
-
MultiMET Sensor
2 Páginas
-
Q-Boat 1800
2 Páginas
-
Riverboat SP ADCP
2 Páginas
-
Software Q-View
2 Páginas
-
UnilogLight
2 Páginas
-
Unilog
2 Páginas
-
DischargeProcessing
4 Páginas
-
Wind Sensors AWS
2 Páginas
-
SEBA Cable Way Installations
4 Páginas
-
LevelSens
2 Páginas
-
RiverRay ADCP
2 Páginas
-
RiverPro ADCP
2 Páginas
-
Q-Boat 1250
4 Páginas
-
High-Speed Riverboat
2 Páginas
-
Channelmaster
2 Páginas
-
MPS-TEC
2 Páginas
-
SEBA Staff Gauges
2 Páginas
-
KLL-(Q)-M1
4 Páginas
-
Mobile Discharge Measurement Systems
8 Páginas
-
Sediment Sampler Type Nielsen
2 Páginas
-
KLL-S
2 Páginas
-
KLL-Q-2
4 Páginas
-
KLL-Light
2 Páginas