A Simple and Safe Solution for Ground Connection Interferences
1 / 2Páginas

{{requestButtons}}

Excertos do catálogo

A Simple and Safe Solution for Ground Connection Interferences - 1

Ground Choke Application Note A Simple and Safe Solution for Ground Connection Interferences Switched mode circuits are increasingly being used today in electronic devices. Due to the rapid switching speeds found in these switched mode circuits, the probability of high frequency ground connection interferences is also becoming more prevalent. A correctly specified and placed ground choke offers a simple and safe solution. Shielded Instrument Cable + -Potential between different earth-ground locations High-frequency current caused by ground loop Shielded Instrument Cable Example of wired device (source: shutterstock) 1) +Potential between different earth-ground locations Today, electric motors are required to operate within an optimal rpm range and, for that reason, are equipped with frequency inverters. LED lights with switch mode power supplies are replacing incandescent bulbs. These are just two examples that showcase the present day trend for increased efficiency and better controllability through the use of the switched mode controls. Regardless of the positive benefits in terms of increased efficiency, these circuits can also lead to increased interferences, which often go unaddressed to date, although they are now becoming more relevant. The topic of overlooked interferences concerns that of high-frequency interferences on the ground as well. The ground receives little attention, compared to interferences generated on the line, during the EMCcompliant design of electronic devices. Yet, this can quickly change if a ground loop develops. Ground line choke 1) interrupts the loop Ground loops develop due to the different impedances of various ground connections from one or more devices. While all ground connections have the same potential for the 50Hz load current, they can have different potentials due to the different line impedances for the high frequency interferences. As a result, switched mode circuits have high frequency currents that can be transferred by the capacitive coupling or via interference suppression capacitors to the ground. There is usually no problem if the ground is good or there is only one ground connection; these currents are conducted to the ground. But, if there are different potentials from two or more ground connections, this can produce high frequency currents. The effects of the equalizing currents on the ground can be drastic: for example, the interferences may damage the electronic control of the device. It is also conceivable that this can result in failure to meet EMC specifications, even though a suitable filter was installed in the device. The problem can be solved by adding a ground choke. The ground choke, however, must be correctly specified in order for it to also satisfy strict safety regulations, with regard to conductor cross section and resistance. Furthermore, the ground choke must be installed so that possible high frequency interference currents on the ground cannot circumvent the choke via the housing. This is particularly a concern with in line filters. These filters are screwed directly to the metal housing for optimal performance. By screwing the filter casing directly to the grounded metal housing, low impedance is achieved, which thereby improves the interference suppression capacitor’s damping properties to ground. Device inlet filters or installed filters that are connected this way, to the mounting flange on the metal housing, are thus connected directly to ground. In addition, they also have a ground connection that is connected via a cable to the housing. If a ground choke is now integrated into the ground cable after the filter, the interference currents can bypass the choke via the metal housing of the device and the filter housing.

Abrir o catálogo na página 1
A Simple and Safe Solution for Ground Connection Interferences - 2

Ground Choke Application Note Incorrect installation: ground currents bypass the ground choke Device inlet filters with SCHURTER’s integrated KFA ground choke Company SCHURTER continues to be a progressive innovator and manufacturer of electronic and electrical components worldwide. Our pro­ ducts ensure safe and clean supply of power, while making equipment easy to use. We offer a broad range of standard products including circuit protection, connectors, EMC products, switches and input systems, as well as electronic manufacturing services. Moreover, SCHURTER is ready to work with our...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos SCHURTER

  1. FMAD NEO

    6 Páginas

  2. THS

    5 Páginas

  3. TTS

    4 Páginas

  4. Product News

    4 Páginas

  5. FMAB NEO

    12 Páginas

  6. FPG1

    4 Páginas

  7. FMAB HV

    6 Páginas

  8. UMT-W

    4 Páginas

  9. OGN

    3 Páginas

  10. 0712

    3 Páginas

  11. CPS

    7 Páginas

  12. DG12

    10 Páginas

  13. 4751

    4 Páginas

  14. FMAD CP

    4 Páginas

  15. 4783

    4 Páginas

  16. EF11

    8 Páginas

  17. PFRY

    4 Páginas

  18. PFRA

    6 Páginas

  19. PFMF

    4 Páginas

  20. PFDF

    3 Páginas

  21. Company Profile

    20 Páginas

  22. Voltage Selector

    1 Páginas

  23. Resettable Fuses

    1 Páginas

  24. 6051.2067

    3 Páginas

  25. 6051.2068

    3 Páginas

  26. 4797-5

    4 Páginas

  27. 6051.2063

    3 Páginas

  28. 6051.2061

    3 Páginas

  29. 6051.2015

    3 Páginas

  30. 3-108-993

    2 Páginas

  31. 3-100-361

    3 Páginas

  32. GP21

    3 Páginas

  33. FMER SOL

    10 Páginas

  34. CMF2, CMF5

    3 Páginas

  35. CDS1

    5 Páginas

  36. DKIH-3

    6 Páginas

  37. 4710-5

    5 Páginas

  38. Touchkit

    3 Páginas

  39. USN 1206

    3 Páginas

  40. FPBB RAIL

    7 Páginas

  41. DD14

    8 Páginas

  42. VAC19KS

    3 Páginas

  43. UMK 250

    4 Páginas

  44. TA35 Rocker 1Pole

    6 Páginas

  45. 4761

    3 Páginas

  46. 4732

    4 Páginas

  47. FUS

    3 Páginas

  48. DKIH

    6 Páginas

  49. FSO

    2 Páginas

  50. CSO

    3 Páginas

  51. CMF1, CMF4

    3 Páginas

  52. FMAC NEO

    5 Páginas

  53. MSM DP 30

    8 Páginas

  54. PSE AE 16

    3 Páginas

  55. MSM LA CS 22

    7 Páginas

  56. MSM LA CS 19

    6 Páginas

  57. PSE AE 30

    5 Páginas

  58. PSE EX 16

    5 Páginas

  59. PSE EX 19

    5 Páginas

  60. PSE NO 19

    6 Páginas

  61. PSE NO 16

    6 Páginas

  62. PSE EX 22

    5 Páginas

  63. PSE NO 27

    6 Páginas

  64. PSE NO 24

    6 Páginas

  65. PSE NO 22

    8 Páginas

  66. PSE IV 16

    6 Páginas

  67. PSE HI 22

    6 Páginas

  68. PSE NO 30

    7 Páginas

  69. PSE M22 IV

    7 Páginas

  70. MCS ES 18

    3 Páginas

  71. MCS ES 22

    3 Páginas

  72. 6051.2094

    3 Páginas

  73. 6051.2093

    3 Páginas

  74. 6051.2078

    3 Páginas

  75. 6051.2077

    3 Páginas

  76. 6051.2070

    3 Páginas

  77. 6051.2072

    3 Páginas

  78. 6051.2071

    3 Páginas

  79. 6051.2037

    2 Páginas

  80. 6051.2030

    3 Páginas

  81. 6051.2032

    3 Páginas

  82. 6051.2031

    3 Páginas

  83. 6051.2027

    3 Páginas

  84. 3-107-570

    2 Páginas

  85. 3-107-569

    2 Páginas

  86. VAC13KS

    4 Páginas

  87. DD21

    5 Páginas

  88. DD11

    5 Páginas

  89. DF11

    6 Páginas

  90. DG11

    7 Páginas

  91. typ_6051.2016

    3 Páginas

  92. typ_6051.2008

    3 Páginas

  93. typ_6051.2009

    3 Páginas

  94. typ_6051.2001

    4 Páginas

  95. typ_6051.2007

    3 Páginas

  96. typ_6051.2003

    3 Páginas

  97. typ_6051.2004

    3 Páginas

  98. typ_4762

    3 Páginas

  99. typ_3-101-514

    3 Páginas

  100. typ_3-101-501

    3 Páginas

  101. typ_3-100-528

    3 Páginas

  102. typ_3-100-734

    3 Páginas

  103. typ_3-100-526

    3 Páginas

  104. typ_3-100-523

    3 Páginas

  105. typ_3-100-524

    3 Páginas

  106. typ_3-100-527

    3 Páginas

  107. typ_3-100-522

    3 Páginas

  108. typ_3-100-356

    3 Páginas

  109. typ_3-100-355

    3 Páginas

  110. typ_3-100-354

    3 Páginas

  111. SWA2

    2 Páginas

  112. PB 1021

    2 Páginas

  113. TM12-111

    6 Páginas

  114. PTS

    4 Páginas

  115. Piezo Keypads

    4 Páginas

  116. PB 1011

    2 Páginas

  117. FMAD CEE

    3 Páginas

Catálogos arquivados

  1. 2020 PFHT

    3 Páginas

  2. Product News 2018

    4 Páginas

  3. PFDF

    3 Páginas

  4. 2015 PFHT

    3 Páginas

  5. PFUF

    3 Páginas

  6. DKFP

    5 Páginas

  7. FMAD RAIL

    3 Páginas

  8. FMAC RAIL

    3 Páginas

  9. FMBD NEO

    6 Páginas

  10. FMAC SINE DCL

    4 Páginas

  11. FMAC SINE

    4 Páginas

  12. FMAB RAIL

    3 Páginas

  13. FMBB NEO

    11 Páginas

  14. FMBB RAIL

    3 Páginas

  15. 5120

    10 Páginas

  16. SMD-FTT

    1 Páginas

  17. OMZ 125

    1 Páginas

  18. 4840.2200

    2 Páginas

  19. 6051.5003

    2 Páginas

  20. 6000.0224

    2 Páginas

  21. 6051.2030

    2 Páginas

  22. 6051.2003

    2 Páginas

  23. FLBB

    2 Páginas

  24. 4741

    2 Páginas

  25. P685

    2 Páginas

  26. KE

    4 Páginas

  27. GSF2

    4 Páginas

  28. GSF1

    5 Páginas

  29. Felcom 64

    4 Páginas

  30. 6135

    5 Páginas

  31. KG-Bowdencable

    4 Páginas

  32. KD-Bowdencable

    4 Páginas

  33. DC21

    3 Páginas

  34. 1074

    4 Páginas

  35. DC11

    5 Páginas

  36. CMF3, CMF6

    2 Páginas

  37. PFNF

    3 Páginas

  38. ESO 10.3x38

    1 Páginas

  39. SHT 6.3x32

    1 Páginas

  40. KEB2

    1 Páginas

  41. New product: 6610

    3 Páginas

  42. New product: CSO

    2 Páginas

  43. TA35 Rocker 2Pol

    8 Páginas

  44. ASO / FSO

    8 Páginas

  45. Varistors

    40 Páginas

  46. Flyer MGA-S

    6 Páginas