YX-361TR
1 / 1Páginas

{{requestButtons}}

Excertos do catálogo

YX-361TR - 1

SANWA ANALOG MULTITESTER YX360 TRF/ YX-361TR General Specifications YX360TRF Meter structure Standard calibration temperature / humidity Operating temperature / humidity Storage temperature / humidity Battery (built-in) fuse (built-in) Withstand voltage 6kV AC (1 min.) between input terminal and case Environmental condition Altitude 2,000m or below, pollution degree II Dimensions / weight Test lead (TL-61T), Hand strap, Instruction manual Test lead (TL-61), Instruction manual HV probe (HV-10T), Clip adapter (CL-11, TL-8IC), hFE probe (HFE-6T) HV probe (HV-10), Clip adapter (CL-11, TL-8IC), hFE probe (HFE-6), Carrying case (C-YS) Accessories Optional accessories Measuring range Input impedance 9k /V 30Hz ~ 100kHz within ±3% f.s. (AC10V) Center value 20 , Max. Value 2k Release voltage 3V 1 range / 0 ~ 15mA at 10 range / 0 ~ 1.5mA at 100 range / 0 ~ 150uA at 1k range / 0 ~ 1.5uA at 100k range 1000 at Optional probe HV-10T is necessary Optional probe HFE-6T is necessary *1: Not including the resistance of fuse. / *2: Pointer indication of the maximum move by charged current in the capacitor. Specification: YX-361TR Measuring range ±3% of full scale ±4% of full scale (10V or below) Terminal voltage drop 250mV Function DCV DCV (NULL) ACV DCmA 0 ~ 0.2 ~ 2k at 1 range, center 20 0 ~ 2 ~ 20k at 10 range, center 200 0 ~ 20 ~ 200k at 100 range, center 2k 0 ~ 200 ~ 2M at 1k range, center 20k 0 ~ 2k ~ 20M at 10k range, center 200k LED for continuity check at 1range (Emitting light at 10 dB LI LV Battery check HV (DC high voltage) Current across test pins 1k range / 0 ~ 1.5mA at 100 range / 10 range / 0 ~ 150mA at 1 range range 3V ~ 0V (Reverse of LI scale) 0 ~ 1.5V ±4% of full scale (10V or below) ±5% of arc ±5% of arc ±5% of full scale Dempa Bldg, 4-4 Sotokanda 2-Chome Chiyoda -ku, Tokyo 101-0021, Japan Tel: + 81- 3 -3251- 0941 Fax : + 81- 3 - 3256 - 9740 Input impedance 9k / V 30Hz ~ 100kHz ±1dB 10V or below 40Hz ~ 30kHz ±3% Current across terminals while object is measured. Voltage applied across terminals while Load current 0.25A Optional probe HV-10 is necessary

Abrir o catálogo na página 1

Todos os catálogos e folhetos técnicos Sanwa Electric Instrument

  1. CD5001

    2 Páginas

  2. General Catalog

    27 Páginas

  3. LP10

    1 Páginas

  4. KD3

    1 Páginas

  5. LX20

    1 Páginas

  6. TH20

    1 Páginas

  7. TH1

    1 Páginas

  8. TH3

    1 Páginas

  9. DM508S

    1 Páginas

  10. PDM5219S

    1 Páginas

  11. HG561H

    4 Páginas

  12. DLC460F

    1 Páginas

  13. DCM600DR

    2 Páginas

  14. DCL31DR

    1 Páginas

  15. DCM660R

    2 Páginas

  16. DCM60R

    1 Páginas

  17. DCL1200R

    2 Páginas

  18. DCM-22AD

    1 Páginas

  19. DCL1000

    2 Páginas

  20. EM7000

    1 Páginas

  21. CD800a

    1 Páginas

  22. RD700

    1 Páginas

  23. PC20

    1 Páginas

  24. PC720M

    2 Páginas

  25. PC700

    2 Páginas

  26. CAM600S

    2 Páginas

  27. AP33

    1 Páginas

  28. PM11

    1 Páginas

  29. CD732

    1 Páginas

  30. KIT-8D

    2 Páginas

  31. PC510a

    1 Páginas

  32. PC500a

    1 Páginas

  33. PC5000 a

    1 Páginas

  34. general cata 2013

    34 Páginas

Catálogos arquivados