Excertos do catálogo

T 1015 EN Type 2 N and Type 2 NI Strainers with flanged connections Application Designed to protect downstream plants, aggregates as well as measuring and control devices against impurities Straining and collecting dirt particles carried along by the medium. Body in PN 10 to 40 · DN 15 to 250 · Flanged connections · Suitable for liquids, steam, and gases up to max. 450 °C The strainers consist of a Y-style body with flanged connections and a wide-meshed filter element (standard strainer insert) or a wide-meshed filter element with an additional fine-meshed filter element (dual strainer insert). Special features •• Compact design with face-to-face dimensions according to DIN •• Easy removal of the collected dirt particles •• Easy replacement of the strainer insert Versions Type 2 N · With standard strainer insert Type 2 NI · With dual strainer insert –– Strainers with DIN flanges –– Cast iron body for PN 10 and 16, DN 15 to 250 –– Spheroidal graphite iron body for PN 16 and 25, DN 15 to 150 –– Cast steel body for PN 16 to 40, DN 15 to 250 –– Cast stainless steel body for PN 16 to 40, DN 15 to 100 Special versions –– With two threaded ports for pressure gauge connection (DN 15 to 100: G ¼, DN 125 to 250: G ½) –– Additional support cage in cases where backflow may occur in vertical pipelines –– With threaded port for rinsing line connection (DN 15: G ¼, DN 20 to 250: G ½) –– Flanges with tongue, male face or female face –– Flanges with groove according to DIN 2512 Fig. 1: Type 2 N and Type 2 NI Strainers Principle of operation The medium flows through the strainer in the direction indicated by the arrow on the body. The uncleaned medium first contacts the inside of the strainer insert (filter element). While it passes through the filter element, the dirt particles carried along by the medium are collected in the filter element. The dirt particles can be removed after undoing the cover flange. Installation · Further details can be found in u EB 1015 The direction of flow must match the direction indicated by the arrow on the body. Leave enough space to remove the filter element for cleaning (see Dimensions and weights). –– Install strainers in vertical pipelines with the medium flowing upward with the cover flange facing upward as indicated by the arrow. In this case, dirt particles are retained but not collected. –– Install swing check valves or similar devices to prevent backflow. SAMSON AKTIENGESELLSCHAFT · Weismüllerstraße 3 · 60314 Frankfurt
Abrir o catálogo na página 1
Table 1: Technical data Type 2 NI fulfills the requirements of DVGW (German Technical and Scientific Association for Gas Ap Pressure loss Z Flow resistance coefficient Pressure-temperature diagram
Abrir o catálogo na página 2
"X" detailed views for special version with pressure gauge connection 1 Body 2 Filter 3 Gasket 4 Cover flange Table 2: Dimensions in mm and weights Ordering text Type 2 N or Type 2 NI Strainer, nominal size DN ..., Nominal pressure PN body material ..., Optionally, special version ...
Abrir o catálogo na página 3
Specifications subject to change without notice
Abrir o catálogo na página 4Todos os catálogos e folhetos técnicos SAMSON
-
TROVIS 5590 Web Module
2 Páginas
-
Room Controller TROVIS 5572
2 Páginas
-
Room Panel TROVIS 5570
2 Páginas
-
Meter Bus Gateway TROVIS 5488
4 Páginas
-
Line Splitter TROVIS 5486
2 Páginas
-
Boiler Controller TROVIS 5474
6 Páginas
-
Proportional Safety Valve Type 2302
2 Páginas
-
Type 50 EM Pressure Reducing Valve
2 Páginas
-
Type 2422/2425 Excess Pressure Valve
6 Páginas
-
Type 2373 Pressure Reducing Valve
4 Páginas
-
Excess Pressure Valve Type M 44-7
4 Páginas
-
Pressure Reducing Valve Type M 44-2
6 Páginas
-
Excess Pressure Valve Type 2408
4 Páginas
-
Pressure Reducing Valve Type 2407
4 Páginas
-
Type 2406 Excess Pressure Valve
6 Páginas
-
Type 2405 Pressure Reducing Valve
6 Páginas
-
Type 43-2 N Temperature Regulator
4 Páginas
-
Type 43-6 Temperature Regulator
4 Páginas
-
Type 43-3 Temperature Regulator
4 Páginas
-
Type 9 Temperature Regulator
6 Páginas
-
Type 8 Temperature Regulator
6 Páginas
-
Temperature Regulator Type 1u
6 Páginas
-
Type 5 D Boiler Controller
2 Páginas
-
Rotary Plug Valve Type 62.7
7 Páginas
-
Actuator Type S
3 Páginas
-
Actuator Type MZ
4 Páginas
-
Actuator Type MN
3 Páginas
-
Actuator Type MD
3 Páginas
-
Actuator Type R
3 Páginas
-
Actuator Type AT
4 Páginas
-
Rotary Plug Valve Type 82.7
7 Páginas
-
Rotary Plug Valve Type 73.7
7 Páginas
-
Rotary Plug Valve Type 73.3
7 Páginas
-
Rotary Plug Valve Type 72.4
7 Páginas
-
Rotary Plug Valve Type 72.3
8 Páginas
-
Expertise in Control Valve Engineering
24 Páginas
-
SAMSON Positioners
28 Páginas
-
SAMSON Product Range (Product catalog)
158 Páginas
Catálogos arquivados
-
T21 11
6 Páginas