Excertos do catálogo

Automation System TROVIS 5500 Room Controller TROVIS 5572 Application Room temperature control in a room by heating or cooling Special features •• Direct access to the operating modes: Automatic mode – Time-of-use – Outside time-of-use •• Room set point and measured room temperature readings displayed Electronics from SAMSON •• Three time schedules configurable separately for each day of the week •• Vacation program mode with different set point •• Temporary set point correction •• Parameterization and configuration directly at the controller or over a station for operation and monitoring •• Communication over Modbus interface for integration into TROVIS 5500 System •• Inputs and outputs extendable using Modbus I/O module (accessories) Operation The current set point for times-of-use and outside times-of-use can be temporarily changed over the and keys when the controller cover is closed. The changed set point remains valid until the next time-of-use starts (automatic mode) or until the operating mode is changed, however, eight hours at the maximum. When the controller cover is opened (Fig. 1) additional operating keys are accessible exist for parameterization and configuration purposes. The changeover key allows the controller time and the time schedules to be altered. Parameters are selected and changed using the , and keys in the Set points, Control and Communication parameter levels. The operating mode can be changed by pressing the matic mode – Time-of-use – Outside time-of-use). Fig. 1: TROVIS 5572 Room Controller (with front cover open)
Abrir o catálogo na página 1
TROVIS 5572 Room Controller Modbus I/O module (1402-0328) Extension of inputs and outputs of the room controller Technical data Technical data Electrical connection and installation Terminal assignment To install and wire the room controller, the housing section needs to be separated from the base. To proceed, press down the tongue on the bottom of the controller and tip the housing section forward to remove it from the base. Screw the base to the wall and connect the wiring. Push the top of the housing section onto the base and push it down. Ordering text TROVIS 5572 Room Controller...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos SAMSON
-
TROVIS 5590 Web Module
2 Páginas
-
Room Panel TROVIS 5570
2 Páginas
-
Meter Bus Gateway TROVIS 5488
4 Páginas
-
Line Splitter TROVIS 5486
2 Páginas
-
Boiler Controller TROVIS 5474
6 Páginas
-
Proportional Safety Valve Type 2302
2 Páginas
-
Type 50 EM Pressure Reducing Valve
2 Páginas
-
Type 2422/2425 Excess Pressure Valve
6 Páginas
-
Type 2373 Pressure Reducing Valve
4 Páginas
-
Excess Pressure Valve Type M 44-7
4 Páginas
-
Pressure Reducing Valve Type M 44-2
6 Páginas
-
Excess Pressure Valve Type 2408
4 Páginas
-
Pressure Reducing Valve Type 2407
4 Páginas
-
Type 2406 Excess Pressure Valve
6 Páginas
-
Type 2405 Pressure Reducing Valve
6 Páginas
-
Type 43-2 N Temperature Regulator
4 Páginas
-
Type 43-6 Temperature Regulator
4 Páginas
-
Type 43-3 Temperature Regulator
4 Páginas
-
Type 9 Temperature Regulator
6 Páginas
-
Type 8 Temperature Regulator
6 Páginas
-
Temperature Regulator Type 1u
6 Páginas
-
Type 5 D Boiler Controller
2 Páginas
-
Rotary Plug Valve Type 62.7
7 Páginas
-
Actuator Type S
3 Páginas
-
Actuator Type MZ
4 Páginas
-
Actuator Type MN
3 Páginas
-
Actuator Type MD
3 Páginas
-
Actuator Type R
3 Páginas
-
Actuator Type AT
4 Páginas
-
Rotary Plug Valve Type 82.7
7 Páginas
-
Rotary Plug Valve Type 73.7
7 Páginas
-
Rotary Plug Valve Type 73.3
7 Páginas
-
Rotary Plug Valve Type 72.4
7 Páginas
-
Rotary Plug Valve Type 72.3
8 Páginas
-
Expertise in Control Valve Engineering
24 Páginas
-
SAMSON Positioners
28 Páginas
-
SAMSON Product Range (Product catalog)
158 Páginas
Catálogos arquivados
-
T21 11
6 Páginas