Excertos do catálogo

Product Information SERPAR® Double Valves with Dual Monitoring Includes Both L-G and E-P Monitors – Sizes 8, 12, & 30 STANDARD SPECIFICATIONS Pilot Solenoid: Two, rated for continuous duty. Standard Voltages: 100-110 volts 50 Hz; 100-120 volts 60 Hz; 24 volts D.C. Power Consumption: Each solenoid, 87 VA inrush, 30 VA holding on 50 or 60 Hz; 14 watts on D.C. Reset Solenoid (E-P): Rated for intermittent duty. Standard Voltages: Same as above for pilot solenoids. Electrical Connections: Terminal Strip Ambient Temperature: 40° to 120° F (4° to 50° C). Media Temperature: 40° to 175° F (4° to 80° C). Flow Media: Filtered air; 5 micron recommended. Inlet Pressure: 30 to 125 psig (2 to 8.5 bar). Reset Pressure (L-G): 60 psig (4 bar) minimum. ROSS’ new SERPAR ® Double Valves with Dual Monitoring provide the reliability and durability you have come to expect from ROSS since the introduction of the rst monitored double valves for mechanical power press safety in 1954. These dual-monitored valves are based on the proven technology of the SERPAR® family of double valves, adding independent signal sources and redundant monitoring to meet CSA Z142 (Canadian Standards Association) requirements for safety circuit performance. Incorporating both ROSS’ L-G and E-P monitoring systems provides redundancy in monitoring through two separate, dissimilar monitors. The actuating solenoids are wired independently through a doublepole, double-throw switch in the E-P monitor. These new SERPAR® Double Valves with Dual Monitoring are available in sizes 8, 12, and 30, with port sizes ranging from 1/2 to 2. The valves mount inline via removable anges, and are available with or without manual overrides. FEATURES: • SERPAR® technology • PACER® solenoid pilots • Dual monitoring – E-P & L-G • Designed to enable • DPDT (double-pole, compliance with current safety regulations double-throw) switch • 3/2 normally closed function • Non-clogging Silencer • Rugged poppet technology
Abrir o catálogo na página 1
VALVE MODEL NUMBERS and MODEL SPECIFIC INFORMATION Model Numbers Nominal Size Port Size With Overrides Without Overrides VALVE MODELS WITHOUT PIPING FLANGES (For replacement purposes) 8 12 30 See corresponding size above. 1/8 external pilot supply port 1/8 pneumatic reset port 1/2 NPSC electrical opening CAUTION ON THE USE OF E-P RESET SOLENOID The E-P reset solenoid is rated only for intermittent duty. Energizing the reset solenoid continuously will nullify the E-P reset function. Customer Svs. 1-800-GET-ROSS Technical Svs. 1-888-TEK-ROSS www.rosscontrols.com WARRANTY and CAUTIONS Standard...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos ROSS Controls
-
safety product
32 Páginas
-
ISO Valves and Serial Bus Communication
56 Páginas
-
Line-Mount Valves
16 Páginas
-
DM2
4 Páginas
-
MD3
16 Páginas
-
CM series
4 Páginas
-
Press Industry Solutions
28 Páginas
-
DM2 Series D
16 Páginas
-
LOX EEZ-ON and LOX with EEZ-ON Valves
20 Páginas
-
filters, regulators and lubricators
84 Páginas
-
Safety-Related Products
32 Páginas
-
Fluid Power Safety Overview
4 Páginas
-
Modular Pneumatic Solutions
8 Páginas
-
Electro-Pneumatic Proportional Valve
2 Páginas
-
Drip Leg Drains
2 Páginas
-
Dale Series Poppet Valves and Manifolds
28 Páginas
-
ISO 5599 I and II VDMA 24563
20 Páginas
-
Series 80 and 84 SAE Std
12 Páginas
-
Series 70 and 74
12 Páginas
-
L -O-X ® V a l v es
4 Páginas
-
W60
4 Páginas
-
foot valves
1 Páginas
-
manual valve
12 Páginas
-
Pilot operated check valves
12 Páginas
-
safety valve
13 Páginas
-
FRL ROSS
12 Páginas
-
poppet valve
16 Páginas
-
TSSA
48 Páginas
Catálogos arquivados
-
ENERGYSAVER® Valve
2 Páginas
-
Ross regulators
2 Páginas
-
serial bus system
29 Páginas
-
Dale series poppet valves
16 Páginas