

Excertos do catálogo

Low power RLD detector heads For the fibre optic laser encoder Renishaw’s RLE fibre optic laser encoder uses interferometry to provide high resolution, high linearity position feedback. The RLE system comprises an RLU laser unit and one or two RLD detector heads. This data sheet describes the low power variants of the RLD detector head. Detector heads are available in low power options for applications requiring a power dissipation lower than the specified < 2 W of the standard RLD. To minimise power dissipation the internal circuitry has been changed and the power LED has been removed; its location has been blackened to avoid confusion. Low power RLD10 0° detector head All deviations from the standard RLD10 are covered in this data sheet - other parameters can be assumed identical to the standard RLD10 as detailed in RLD10 0º detector head data sheet (Renishaw part no. L-9904-2348) and RLE fibre optic laser encoder installation guide (Renishaw part no. M-5225-0568). Low power RLD10 90° detector head Specification deviation Heat dissipation Maximum speed** * This has an estimated axis-to-axis variation of ±3% ** This applies to all available digital quadrature output resolutions and analogue quadrature output. Low power differential interferometer detector head Legislative - Laser safety: In accordance with IEC/EN60825-1, IEC/EN60825-2 and US standards 21CFR 1040 and ANSI Z136.1, Renishaw RLE lasers are Class II lasers and safety goggles are not required, since the blink reaction of a human will protect the eye from damage. Do not stare into the beam or shine it into the eyes of others. It is safe to view a diffuse-reflected beam. Do not dismantle the unit in any way; doing so may expose laser radiation in excess of Class II limits. Renishaw reserves the right to change specifications without notice. © Renishaw plc 2014 For worldwide contact details, please visit our main website at www.renishaw.com/contact Printed in England 0114 Part No. L-9904-24
Abrir o catálogo na página 1Todos os catálogos e folhetos técnicos RENISHAW
-
Metrology fixture table
4 Páginas
-
Brochure: XR20 rotary axis calibrator
12 Páginas
-
Brochure: OMP60
6 Páginas
-
OLP40 flyer
6 Páginas
-
RFP1 fringe probe for REVO-2
2 Páginas
-
RVP vision probe for REVO-2
2 Páginas
-
RUP1 ultrasonic probe for REVO-2
2 Páginas
-
MH20 articulating probe head
2 Páginas
-
Flyer: MH20i indexing probe head
2 Páginas
-
Data sheet: MH20 and MH20i
4 Páginas
-
RTP20
2 Páginas
-
PH10M-iQ PLUS
2 Páginas
-
TP200 precision touch trigger probe
2 Páginas
-
TP20 touch trigger probe system
2 Páginas
-
PH20 5-axis touch-trigger system
4 Páginas
-
REVO-2 and RSP2 probes
2 Páginas
-
SFP2 surface finish probe
2 Páginas
-
Data sheet: RPI30 parallel interface
3 Páginas
-
Data sheet: HS20 laser head
2 Páginas
-
Data sheet: RLU20 laser unit
2 Páginas
-
Data sheet: RLU10 laser unit
2 Páginas
-
Data sheet: RLE system performance
6 Páginas
-
Brochure: XK10 alignment laser system
16 Páginas
-
Brochure: XL-80 laser measurement system
28 Páginas
-
Brochure: XM-60 multi-axis calibrator
24 Páginas
-
RLMD01_09
13 Páginas
-
RLBD01_04
9 Páginas
-
RLCD03_03
9 Páginas
-
HiLin™
20 Páginas
-
Advanced Diagnostic Tool ADTa-100
2 Páginas
-
RSP3-1 to RSP3-4 probes for REVO-2
2 Páginas
-
SLM 250 scanning laser module
2 Páginas
-
PRIMO™ system
8 Páginas
-
TP7M probe and stylus kit
5 Páginas
-
PH10 PLUS motorised probe head range
2 Páginas
-
RSP3-6 extended reach probe
4 Páginas
-
RGH25F UHV, RGH20F UHV
8 Páginas
-
RGH22 series readhead
4 Páginas
-
Renishaw retrofit
12 Páginas
-
Renishaw fixtures
8 Páginas
-
SP80
4 Páginas
-
SP600
4 Páginas
-
RMI-Q multiple radio probe interface
6 Páginas
-
SPRINT? high-speed scanning system
7 Páginas
-
Equator the versatile gauge
4 Páginas
-
Non-contact encoder products guide
20 Páginas
-
High performance 5-axis measurement
16 Páginas
-
Styli for Zeiss applications
57 Páginas
-
Precision styli
60 Páginas
-
CMM technology guide
28 Páginas