Excertos do catálogo

Miniature Circuit-Breaker IEC LS Series 8562 - 1

Series 8562/5 miniature circuit-breakers meet all technical requirements relating to safe and selective tripping. When short-circuits occur, they restrict the load on the installed circuits due to their excellent current limiting and related high breaking capacity and provide a high level of discrimination for lineside fuses. > 1 to 3 pole versions > Rated current from 0.5 ... 40 A > 6 or 10 kA breaking capacity to DIN VDE 0641, respectively EN 60898 > Isolating Function to EN 60947-2 > Permanently set thermal and magnetic trips > Power limitation class 3 Components for System Solutions E9/1

Abrir o catálogo na página 1
Miniature Circuit-Breaker IEC LS Series 8562 - 2

Selection Table other versions and accessories on request E9/2 Components for System Solutions

Abrir o catálogo na página 2
Miniature Circuit-Breaker IEC LS Series 8562 - 3

Miniature Circuit-Breaker IEC Series 8562 Selection Table Components for System Solutions E9/3

Abrir o catálogo na página 3
Miniature Circuit-Breaker IEC LS Series 8562 - 4

Miniature Circuit-Breaker 1-pole Selection Table - Order Specific Configuration Version / Version Breaking capacity AC AC UL Auxiliary contact without E9/4 Components for System Solutions 8562/..-...4-... 8562/..-...5-... -005 8562/..--005

Abrir o catálogo na página 4
Miniature Circuit-Breaker IEC LS Series 8562 - 5

Miniature Circuit-Breaker IEC Series 8562 Miniature Circuit-Breaker 1-pole Selection Table - Order Specific Configuration Version / Breaking capacity Version Breaking capacity Auxiliary contact 1 CO Fault signal 1 CO Rated operational 6 current in A 10 Components for System Solutions E9/5

Abrir o catálogo na página 5
Miniature Circuit-Breaker IEC LS Series 8562 - 6

Miniature Circuit-Breaker 1-pole + N Selection Table - Order Specific Configuration Version / Breaking capacity Version Breaking capacity Auxiliary contact E9/6 Components for System Solutions ..4-... ..5-... ...-005 ...-010 ...-020 ...-030 ...-040 ...-060 ...-100 ...-130 ...-160 ...-200 ...-250 ...-320

Abrir o catálogo na página 6
Miniature Circuit-Breaker IEC LS Series 8562 - 7

Miniature Circuit-Breaker 2-pole Selection Table - Order Specific Configuration Version / Breaking capacity Auxiliary contact Rated operational current in A Version AC AC AC / DC UL UL 135 % without 1 CO Fault signal 1 CO order spec. 0.5 1 2 3 4 6 10 13 16 20 25 32 Components for System Solutions E9/7

Abrir o catálogo na página 7
Miniature Circuit-Breaker IEC LS Series 8562 - 8

Miniature Circuit-Breaker 2-pole Selection Table - Order Specific Configuration Version / Version Breaking capacity Auxiliary contact without 8562/..-...0-... -- E9/8 Components for System Solutions 8562/..-...4-... 8562/..-...5-... -005 8562/..--005

Abrir o catálogo na página 8
Miniature Circuit-Breaker IEC LS Series 8562 - 9

Miniature Circuit-Breaker 3-pole Selection Table - Order Specific Configuration Version / Breaking capacity Auxiliary contact Rated operational current in A Version Breaking capacit without 1 CO Fault signal 1 CO 2 CO - 1 CO normal and fault signal 1 CO 0.5 1 2 3 4 6 10 13 16 20 25 32 Components for System Solutions E9/9

Abrir o catálogo na página 9
Miniature Circuit-Breaker IEC LS Series 8562 - 10

Miniature Circuit-Breaker 3-pole Selection Table - Order Specific Configuration Version / Version Breaking capacity Auxiliary contact without 8562/ 1 CO -Fault signal 1 CO - 2 CO - 1 CO normal and fault signal 1 CO -- Miniature Circuit-Breaker 3-pole + N Selection Table - Order Specific Configuration Module width Order Number Width 99 mm 8562/54-4...- Order Number Supplement Version / Breaking capacity Auxiliary contact Rated operational current in A Version Breaking capacity without 1 CO Fault signal 1 CO 2 CO - 1 CO normal and Fault signal 1 CO 6 10 13 16 20 25 32 E9/10...

Abrir o catálogo na página 10
Miniature Circuit-Breaker IEC LS Series 8562 - 11

Miniature Circuit-Breaker 3-pole + N Selection Table - Order Specific Configuration Version / Version Breaking capacity 2 CO - 1 CO normal and Fault signal 1 CO 8562/ Components for System Solutions E9/11

Abrir o catálogo na página 11
Miniature Circuit-Breaker IEC LS Series 8562 - 12

Explosion Protection Marking lECEx Europe (ATEX) Certificates lECEx Europe (ATEX) Other certificates IECEx PTB 06.0062U PTB 02 ATEX 1049 U Belarus (Gospromnadzor) Technical Data Device version Version No. of poles Electrical data Version Rated operational voltage AC MCBs 1 pole, 1 pole + N, 2 pole, 3 pole, 3 pole + N AC / DC MCBs 1 pole, 2 pole AC MCBs Standard version AC DC 1 pole + N 230 V - - AC / DC MCBs Standard version AC DC 1 pole + N - - - - Minimal Voltage Ubmin Maximal Voltage Ub max Rated insulation voltage 500 V 500 V Rated operational current Tripping...

Abrir o catálogo na página 12
Miniature Circuit-Breaker IEC LS Series 8562 - 13

Miniature Circuit-Breaker IEC Series 8562 Technical Data Electrical data Tripping characteristic curves Components for System Solutions

Abrir o catálogo na página 13
Miniature Circuit-Breaker IEC LS Series 8562 - 14

Technical Data Electrical data Tripping characteristic curves Selectivity class 3 (IEC/EN 60898) Breaking capacity 6 kA resp. 10 kA Rated switching capacities AC MCBs Poles Series with 6 kA Series with 10 kA DC to IEC/EN 609472 (Time constante 15 ms) Circuit breaker, current limiting with thermal and magnetic release E9/14 Components for System Solutions 2016-04-04-EK00-ili-en

Abrir o catálogo na página 14
Miniature Circuit-Breaker IEC LS Series 8562 - 15

Technical Data Characteristics Characteristic to IEC/EN 60898 Rated current range Loads Normal temperature Thermal overload trip Thermal overload trip 135% UL Magnetic trip B 6 ... 32 A > Elektric heatings > Lighting > Socket outlet circuits > Control circuits e.t.c. 30 °C 1.13 ... 1.45 In > Operating equipment > Light fitting groups > Motors > Transformers D 0.5 ... 32 A > Operating equipment > Motors with heavy starting characteristic e.t.c. 30 °C 1.13 ... 1.45 In Components for System Solutions E9/15

Abrir o catálogo na página 15
Miniature Circuit-Breaker IEC LS Series 8562 - 16

Technical Data Electrical data Response value of short-circuit trip Back-up protection The response value of the short-circuit trip is approximately 40 % higher for DC than for AC at 50 / 60 Hz Fuses must be fitted upstream to protect miniature circuit-breakers against high short-circuit currents in high power networks. These protect the miniature circuit-breakers against short-circuit currents of up to 50 kA. If a short-circuit occurs, both protective devices cut out simultaneously, so that the miniature circuit-breaker is not destroyed and remains fully functional. Following MCBs...

Abrir o catálogo na página 16
Miniature Circuit-Breaker IEC LS Series 8562 - 17

Technical Data Mechanical data Degree of protection Degree of protection acc. to IEC/EN 60529 Connecting terminals IP20 Material Enclosure Epoxy resin Mounting / Installation Terminals Main contacts 1.5 ... 10 mm2 clamp terminals Auxilliary contacts 1.5 mm2 clamp terminals Universal current +/-, 1 pole Universal current +/-, 2 pole Fault indication contact 1 CO Auxiliary contact 1 NO Fault indication contact 1 NO 12219E00 Auxiliary contact 1 CO Fault indication contact 1 CO Undervoltage trip Components for System Solutions E9/17

Abrir o catálogo na página 17

Todos os catálogos e folhetos técnicos R. STAHL AG

  1. NETWORK TECHNOLOGY

    20 Páginas

  2. CATALOGUE 2018

    1094 Páginas

  3. Ex-Poster

    1 Páginas

  4. BROCHURE: LIGHTING

    24 Páginas

  5. AK00_III

    12 Páginas

  6. EN/IEC 61439

    4 Páginas

  7. SERIES 200

    8 Páginas

  8. HMI Oil and Gas

    20 Páginas

  9. HMI Overview

    36 Páginas

  10. SolConeX

    12 Páginas

  11. GUBox

    4 Páginas

  12. EXLUX 6001

    4 Páginas

  13. Focus customer

    24 Páginas

  14. AK00_III

    5 Páginas

  15. BinaryOutput_Auto

    5 Páginas

  16. 9160601310_de_en

    24 Páginas

  17. Lighting

    16 Páginas

  18. Isolators

    6 Páginas

  19. Safety Barriers

    27 Páginas

  20. Ex Magazine 2012

    70 Páginas

  21. IS1+Remote I/O

    16 Páginas

  22. Stahl - Catalog

    1306 Páginas

Catálogos arquivados

  1. ISpac isolators

    16 Páginas

  2. IS1 remote I/O

    12 Páginas

  3. Fieldbus Solutions

    16 Páginas

  4. Cable glands

    18 Páginas

  5. Lighting

    16 Páginas

  6. Company brochure

    24 Páginas

  7. Marine Solutions

    24 Páginas