IsolatingRepeater_AK00_III_
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

IsolatingRepeater_AK00_III_ - 1

Fibre Optics Fieldbus Isolating Repeater Series 9186 > Easy installation and mainetance due to: – Inherently safe optical interface – Intrinsically safe bus connection via RS-485 IS (PNO) > High availability due to: – Build-up of ring structures, redundant Point-to-Point, line structures – Integrated analysis of optical input signal – Error message if critical levels of input signal reached > Transmission of Profibus DP, Modbus, HART on RS-485, R. STAHL Servicebus > 9186/.5 – Installation in Zone 2 possible > 9186/12 – Installation in Zone 1 and Zone 2 possible – Fieldbus interface for intrinsically safe Profibus DP (PNO) The Fibre Optic Isolating Repeater is used to build-up fibre optic network structures in hazardous areas. It enables to transmit Profibus DP or Modbus signals over distances of up to 2 km or 1,2 miles. The optical interfaces are designed to be inherently safe (Ex op is). The protection scheme Ex op is allows to apply usual standardized industry connectors. The Zone 1 / Div. 2 version of the Fibre Optic Isolating Repeater offers an intrinsically safe RS-485 interface acc. to the standard RS-485 IS (PNO). Critical levels of the received optical signal are detected by the integrated diagnostic function. The fault is indicated by LEDs on the front side of the device and in addition by a line fault contact. The contact is used to trigger a remote fault indication in the control room. The diagnostic function enables preventive maintenance and improves the availability of the plant. IECEx / ATEX

Abrir o catálogo na página 1
IsolatingRepeater_AK00_III_ - 2

Fibre Optics Fieldbus Isolating Repeater Series 9186 Selection Table Version Network structure Order number Fibre optics fieldbus isolating repeater Series 9186 Ring, point-to-point redundant, line Zone 2 and in the safe area Ring, point-to-point redundant, line Explosion Protection Global (IECEx) Version Installation in Gas and dust Europe (ATEX) Version Installation in Gas and dust Certifications and certificates Version Installation in Certificates Ship approval Safety data Version Installation in Max. voltage Uo Max. current Io Max. power Po For connection RS 485 IS Max. permissible...

Abrir o catálogo na página 2
IsolatingRepeater_AK00_III_ - 3

Fibre Optics Fieldbus Isolating Repeater Series 9186 Technical Data Electrical data Version Installation in Auxiliary power Nominal voltage UN Voltage range Residual ripple Nominal current (at UN) Power input Operation indication Polarity reversal protection Galvanic separation Test voltage acc. to standard between RS-485 and power supply Ex i RS485 to power supply Error-contact to power supply PA to power supply Ex i RS 485 to error-contact Ex i RS 485 to PA Error contact to PA Optical interface Protocols Network topologies Redundancy Connection Wavelength Transmission distance Recommended...

Abrir o catálogo na página 3
IsolatingRepeater_AK00_III_ - 4

Fibre Optics Fieldbus Isolating Repeater Series 9186 Technical Data Fault control Power supply failure Transmission level is good Transmission level reduced (-1,5 dBm) Fibre breakage or transmission level is too low (-3 dBm) Version Installation in Switching capacity of fault-contact Ambient conditions Version Installation in Ambient temperature Storage temperature Relative humidity (no condensation) Connectors Version Installation in Power supply Fault-contact Screen connection to PA Serial connection Shield Fibre optic cable Mechanical data Version Installation in Weight Mounting type...

Abrir o catálogo na página 4
IsolatingRepeater_AK00_III_ - 5

Fibre Optics Fieldbus Isolating Repeater Series 9186 Technical Data Electrical connection Connection diagram Accessories and Spare Parts Designation 9-pin for connection of the fieldbus or ServiceBus to the CPU & power module Series 9440/15 and fieldbusisolating repeater 9185. Integrated terminator can be switched on or off. For non-intrinsically safe RS-485. 9-pin for connection of the fieldbus or ServiceBus to the CPU & power module Series 9440/22 and fieldbusisolating repeater 9185. Integrated terminator can be switched on or off. For RS-485 IS to PNOstandard. 9-pin, for connection of...

Abrir o catálogo na página 5
IsolatingRepeater_AK00_III_ - 6

Fibre Optics Fieldbus Isolating Repeater Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations Safe area Hazardous area Safe area Hazardous area Point-to-Point structure Line structure We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos R. STAHL AG

  1. NETWORK TECHNOLOGY

    20 Páginas

  2. CATALOGUE 2018

    1094 Páginas

  3. Ex-Poster

    1 Páginas

  4. BROCHURE: LIGHTING

    24 Páginas

  5. AK00_III

    12 Páginas

  6. EN/IEC 61439

    4 Páginas

  7. SERIES 200

    8 Páginas

  8. HMI Oil and Gas

    20 Páginas

  9. HMI Overview

    36 Páginas

  10. SolConeX

    12 Páginas

  11. GUBox

    4 Páginas

  12. EXLUX 6001

    4 Páginas

  13. Focus customer

    24 Páginas

  14. AK00_III

    5 Páginas

  15. BinaryOutput_Auto

    5 Páginas

  16. 9160601310_de_en

    24 Páginas

  17. Lighting

    16 Páginas

  18. Isolators

    6 Páginas

  19. Safety Barriers

    27 Páginas

  20. Ex Magazine 2012

    70 Páginas

  21. IS1+Remote I/O

    16 Páginas

  22. Stahl - Catalog

    1306 Páginas

Catálogos arquivados

  1. ISpac isolators

    16 Páginas

  2. IS1 remote I/O

    12 Páginas

  3. Fieldbus Solutions

    16 Páginas

  4. Cable glands

    18 Páginas

  5. Lighting

    16 Páginas

  6. Company brochure

    24 Páginas

  7. Marine Solutions

    24 Páginas