Excertos do catálogo
HVAC and pressurization IECEx and ATEX
Abrir o catálogo na página 1Heating Ventilation & Air Conditioners Starting in the 1950s air conditioners have become standard features in residential and industrial applications. Although explosion protection started around 100 years ago, forced cooling in such an environment has always been a challenge. Demands as applicable in the oil and gas industry are quite different to a residential or standard industrial application. For many years now air conditioners form a standard ingredient for the comfort of people around the world. Especially in the oil and gas industry it is essential to have a controlled and safe...
Abrir o catálogo na página 2Selecting your HVAC unit 9 HVAC Request Form 11
Abrir o catálogo na página 3LIFTING LUGS (OPTIONAL) PURGE £ PRESS AUXILIARY BLOWER EVAPORATOR BLOWER ELECTRIC HEATER EVAPORATOR COIL DYPASS DAMPER Optional features • 304/316 stainless steel cabinet • Multiplexer: capable of control- ling many separate units conserving power) • Explosion protected crankcase heater • Purge & pressurization add-on back-up) can assist in purging • Copper fin/copper tube coils with highly corrosion resistance • Coil coatings: Esgard, TechniCoat, E-Coat, Heresite, and Thermoguard • Extra corrosion protection • Chemical filtration- Remotely mounted control system • Special and high...
Abrir o catálogo na página 4Redundancy The cooling part of our HVAC has our unique standard redundancy design concept. Depending on the climatic data and type of application following redundancy features are possible. 10 kW Cooling capacity automatically includes a redundant design consisting of two independent 5kW air conditioning systems. If one system fails, the application can still run under most normal operational conditions. Dual redundancy design is available enabling 100% backup power. This is applicable for high load equipment cooling and demanding highest ambient temperatures. N+1 redundancy is also...
Abrir o catálogo na página 5Purge & pressurization The InPac HVAC system can provide ATEX certified pressurization to a building or other suitable shelters. The used protection method is also based on the latest EN and IEC standard and suitable for Zone 1 or Zone 2. Figure 1. Typical use of Backup Blower for Purge/Pressurization. Under normal operation, one set of blowers is operating, taking air from the outside and circulating it through area. Figure 2. Typical use of Backup Blower for Purge/Pressurization. During purge, all blowers are active and the return air disengaged, which forces protective air into the area...
Abrir o catálogo na página 6Safe atmosphere ChemPac add-on can be used where the control of gaseous contaminations may be a concern. The ChemPac is an optional feature for the InPac series and is available in multiple sizes to match customer requirements. The ChemPac typically combines four stages of filtration for removal of airborne pollutants and corrosive gases when combined with one of our air conditioning units. Along with pellet filtration media, we also offer adsorbent honeycomb media as a solution. The honeycomb modules provide increased rate of adsorption of gases and significantly lower pressure drop, a...
Abrir o catálogo na página 7Solutions Electromach B.V. situated in The Netherlands, has more than 50 years experience in manufacturing explosion protected systems for hazardous areas. Our system solutions department is specialized in developing custom made skids and container-based solutions. Our organisation is all-round certified for designing ATEX and IECEx systems. We are supported by a 13.000 m² electrical and mechanical workshop including specialized container workshop. Our team is happy to support you in a 'ready for connection' solution enabling: Minimizing project costs Shortened turn around One stop shopping...
Abrir o catálogo na página 8Selecting your HVAC unit #1 Required Cooling Load Required cooling load is determined by the size of the area to be conditioned including total interior volume, number of occupants, total heat contribution of all electrical equipment contained in the area, thermal isolation values of wall, floor, and ceiling insulation system, as well as the final geographical destination of the unit/building. Our trained staff will be happy to assist you in preparing a very detailed computerized load study calculation for your unique application. #2 Hazardous Location Depending on the types of hazardous...
Abrir o catálogo na página 9Cooling power (kW) Model selection Cooling power (kW) Model selection
Abrir o catálogo na página 10HVAC Request Form Company name building description Building size insulation factor equipment heat load, sensible equipment heat load, latent lighting head load number of building personnel location of building avg. design temp. outside: db/wb avg. design temop. inside: dw/wb voltage Number of air changes building pressure requirement building sketch
Abrir o catálogo na página 11E-mail: info@electromach.nl 9200 Dendermonde (Sint-Gillis), Belgium E-mail: info@stahl.be
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos R. STAHL AG
-
IS1+ The Remote I/O
16 Páginas
-
NETWORK TECHNOLOGY
20 Páginas
-
HMIs IN OIL & GAS APPLICATIONS
20 Páginas
-
Actuators Series 8602/3
20 Páginas
-
PRODUCT CATALOGUE 2019
909 Páginas
-
Analogue Thermal Imaging Camera
3 Páginas
-
electrical catalog 9016
236 Páginas
-
IS1+ Remote I/O - future inside
16 Páginas
-
CATALOGUE 2018
1094 Páginas
-
Floodlight LED Series 6125
7 Páginas
-
LED floodlight 6125
2 Páginas
-
WLAN ACCESS POINT SERIES 7145/5
4 Páginas
-
WLAN ACCESS POINT 8265
5 Páginas
-
MOUNTING PLATE SERIES 8298/02
6 Páginas
-
ModibEx by R. STAHL
4 Páginas
-
Small Fuse Bases Series 8560
4 Páginas
-
Contactor Relay Series 8510
5 Páginas
-
Ex-Poster
1 Páginas
-
LED tubular light fitting 6036
4 Páginas
-
BROCHURE: LIGHTING
24 Páginas
-
Signalling_Catalogue_S2_2014
148 Páginas
-
Condensed Catalogue 2015
622 Páginas
-
LinearLuminaire_EK00_III
7 Páginas
-
AK00_III
12 Páginas
-
EN/IEC 61439
4 Páginas
-
Seminare D-A-CH 2014
25 Páginas
-
IsolatingRepeater_AK00_III_
6 Páginas
-
AnalogInputModule_AK00_III
5 Páginas
-
SERIES 200
8 Páginas
-
HMI Oil and Gas
20 Páginas
-
HMI Overview
36 Páginas
-
SolConeX
12 Páginas
-
Together we invent the solution
12 Páginas
-
GUBox
4 Páginas
-
Pedant light fittings
16 Páginas
-
Inspection Light 6149/2
4 Páginas
-
Portable Lamp 6148
4 Páginas
-
EXLUX 6001
4 Páginas
-
Focus customer
24 Páginas
-
IsolatingRepeater_AK00_II
6 Páginas
-
AK00_III
5 Páginas
-
EnclosuresForFieldstations_AK00_II
7 Páginas
-
BinaryOutput_Auto
5 Páginas
-
9160601310_de_en
24 Páginas
-
STAHL HMI Solutions
32 Páginas
-
Flyer plugs and sockets SolConex
2 Páginas
-
Distributing and Controlling
19 Páginas
-
UPS Uninterrupted Power Supply
4 Páginas
-
Lighting
16 Páginas
-
Competence at a glance
24 Páginas
-
Isolators
6 Páginas
-
Safety Barriers
27 Páginas
-
Ex Magazine 2012
70 Páginas
-
IS1+Remote I/O
16 Páginas
-
Stahl - Catalog
1306 Páginas
Catálogos arquivados
-
ISpac isolators
16 Páginas
-
IS1 remote I/O
12 Páginas
-
Fieldbus Solutions
16 Páginas
-
Cable glands
18 Páginas
-
Lighting
16 Páginas
-
Distributing and Controlling
20 Páginas
-
Company brochure
24 Páginas
-
Marine Solutions
24 Páginas
-
Poster Explosion Protection
1 Páginas
-
The basics of dust-explosion protection
32 Páginas
-
The basics of explosion protection
48 Páginas