RGA
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

RGA - 2

RGA - Residual Gas Analyzer The Extrel RGA is a reliable, easy-to-use residual gas analyzer that includes full range pressure measurement. An intelligent start-up design allows for the system to know when to switch from the Pirani to the ion gauge and finally to the quadrupole system. The Extrel RGA is a high performing RGA at an affordable price, which makes the system an ideal choice for Background Gas Analysis, Leak Detection and Vacuum Chamber Characterization. RGA Advantages: • Modular compact design for ease of installation and maintenance • Full pressure measurement with built-in...

Abrir o catálogo na página 2
RGA - 3

Overview The RGA100 and RGA300 are the ultimate residual gas measurement probes. A single device, mounted on a 2-3/4 inch flange, contains a Pirani gauge, an ion gauge and a quadrupole mass analyzer. All Extrel models start at 1 amu. The RGA100 goes to 100 amu and the RGA300 goes to 300 amu. Long-Life Dual Filaments and Ion Source Kits Dual thoria-coated iridium filaments are used for electron emission for both the quadrupole and ion gauge operation. The filaments are protected against stress from vacuum excursions by both the ion and the Pirani functions. Because of these protections, our...

Abrir o catálogo na página 3
RGA - 4

Trend Mode The peak intensities of up to 10 ions of interest can be followed as a function of time. Peaks to be monitored are set in a Mass Table where mass, description, dwell time for acquisition, color of trace, high and low alarms can be set. The user has full control over how the data is displayed and exported. Relative Standard Deviations in terms of normalized concentrations: N2: 0.27%, O2: 1.20%, Ar: 1.26%, CO2: 2.86% Leak Detection Mode It is just a matter of placing the gas of choice into the table. The intensity trace of the leak detection peak is then shown on the graph. Leak...

Abrir o catálogo na página 4
RGA - 5

RGA VacuumPlus Software All Extrel RGA systems come standard with the VacuumPlus Real-Time Windows® software package. An intuitive graphical user interface makes the total functionality of the Extrel system available to the user. Complete pump-down may be monitored quickly and easily. For further analysis, XML data files (text format) can be saved for transfer into spreadsheets, and graphic images can be save or copied into other Windows programs. Powerful Operational Modes The VacuumPlus software comes with the operation modes of Analog Sweep mode, Trend mode, Leak Detect mode and...

Abrir o catálogo na página 5
RGA - 6

RGA Specifications Mass Range: Electron Emission Current: 0.2 to 5 mA, programmable Probe Dimension: Mass Filter Type: 6 mm Quadrupole Detector Type: • Faraday cup only or with Electron Multiplier Resolution: Better than 0.5 amu (adjustable) • 172.52 mm (6.79 inches) from flange face to top of ionizer CCU Extension: • 139.65 mm (5.50 inches) from flange face Minimum Tube I.D.: • 31.75 mm (1.25 inches) probe mounting Sensitivity (A/Torr): 5 x 10-4 A/Torr Minimum Detectable Partial Pressure: Full Pressure Measurement: • Pirani Gauge: > 10-2 Torr Maximum Operating Temperature: 50°C • 81.99 mm...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos Process Insights

  1. HALO Max QCL™

    4 Páginas

  2. SERIES 2000

    5 Páginas

  3. QuickTONultra

    4 Páginas

  4. T12

    4 Páginas

  5. SERIES 3520™

    4 Páginas

  6. SERIES 3000™

    4 Páginas

  7. SERIES 2520™

    4 Páginas

  8. ZRO 2000™

    4 Páginas

  9. OXY-SEN™

    4 Páginas

  10. SERIES 1300™

    4 Páginas

  11. PCM 5000™

    2 Páginas

  12. PCM 1000™

    4 Páginas

  13. EVM™

    4 Páginas

  14. Diamond 20™

    4 Páginas

  15. Diamond MX™

    4 Páginas

  16. RefinIR™

    4 Páginas

  17. RovIR™

    4 Páginas

  18. Fiber Optic Cable

    4 Páginas

  19. G-SST™

    4 Páginas

  20. RTD-SST

    4 Páginas

  21. O-SST

    4 Páginas

  22. SST

    4 Páginas

  23. ClearView

    4 Páginas

  24. LAB 508 UV-VIS

    8 Páginas

  25. 508 UV-VIS

    8 Páginas

  26. LAB NIR-O

    8 Páginas

  27. QuickTOCtrace™

    8 Páginas

  28. QuickTOCuv™

    4 Páginas

  29. QuickCODlab™

    8 Páginas

  30. ToxAlarm™

    4 Páginas

  31. NitriTox™

    4 Páginas

  32. QuickTOCeco™

    4 Páginas

  33. MB

    8 Páginas

  34. HRQ

    6 Páginas

  35. APIMS

    2 Páginas

  36. MAX-QMS

    2 Páginas

  37. MAX300-EGA

    8 Páginas

  38. MAX300-CAT

    4 Páginas

  39. MAX300-BIO

    8 Páginas

  40. MAX300-AIR

    8 Páginas

  41. MAX300-RTG™ 2.0

    8 Páginas

  42. MODEL ESS-SCVP™

    8 Páginas

  43. HDT

    8 Páginas

  44. XDT

    8 Páginas

  45. XPDM

    8 Páginas

  46. LPDT2

    4 Páginas

  47. Spark H2 O in CO2

    6 Páginas

  48. HALO KA H2O

    3 Páginas

  49. HALO OK

    8 Páginas

  50. HALO H2O in N2O

    2 Páginas

  51. HALO H2

    4 Páginas

  52. HALO 3 NH3

    3 Páginas

  53. HALO 3 HCI

    3 Páginas

  54. HALO 3 CH4

    3 Páginas

  55. HALO 3 H2O

    4 Páginas

  56. HALO 3 D2O/HDO

    4 Páginas

  57. HALO 3 CO2

    4 Páginas

  58. HALO 3 CO

    2 Páginas

  59. HALO 3 CH2O

    2 Páginas

  60. HALO KA Max

    4 Páginas

  61. VeraSpec™ APIMS

    2 Páginas

  62. 973

    8 Páginas

  63. 573

    8 Páginas

  64. Zircomat

    8 Páginas

  65. 9610

    8 Páginas

  66. 9800 Calorimeter

    4 Páginas

  67. MAX300-RTG 2.0

    8 Páginas

Catálogos arquivados