BENEFITS Cost Effective • Most economical monitoring of fixed points at timed intervals • Low cost per sample location • Monitors a much larger area than a fixed particle counter • Ethernet communications to facility monitoring system Flexible • Easily programs a sampling routine, for either simple or complex sequences • Automatically changes sampling recipe upon receiving alarm or external signal • Large coverage area: each sample point can be up to 125 ft away Rapid and Accurate Measurements • Patented flow control ensures the manifold properly Manifold Pump Manifold Module The AM II manifold offers advanced features for sequentially monitoring aerosol contamination at multiple locations with a fixed particle counter. The AM II is ideal for trend analysis and cleanroom verification when continuous monitoring is not needed. compensates for manifold pressure drop, eliminating systematic particle undercounting of up to 15% • Maintains constant flow (nominal 3 CFM) at each sample location to minimize gravitational particle settling • With isokinetic sampling probes, captures particles at same velocity as sample air, preventing distortion in particle size relationships F E AT U R E S • Multiplexed monitoring of up to 32 locations with a CO M PAT I B I L I TY • Lasair® II or Lasair III particle counters, or IsoAir® PLUS particle sensor single particle counter Controlled by Facility Net or Pharmaceutical Net software Programmable recipes and sample point sequences Assembly designed to eliminate contamination from valves Alarm for low vacuum; automatic shut-off for pump overheating A P P L I C AT I O N S • Facility monitoring • Monitoring large minienvironments • Cleanroom verification and trend analysis
Abrir o catálogo na página 1
Manifold System Sample ports Max. 16, Min. 10 Max. 32, Min. 22 Use in locations ISO 8 (Class 100,000) or cleaner 0.1 to 0.3 µm particle counters: Use to simultaneously monitor ISO 3, 4, 5, and 6 (Classes 1, 10, 100, 1000) 0.5 to 5.0 µm particle counters: Use to simultaneously monitor ISO 5, 6, 7, and 8 (Classes 100, 1000, 10,000, 100,000) Operating range Manifold Pump Pumps required Flow rate Safety provision Power Dimensions (l, w, h); weight 1 (single-phase) > 100 ft3/min Automatic pump shutoff 105 – 125 VAC, 60 Hz or 220-240 VAC, 50 Hz 10.9 Amp, single-phase Manifold Module Flow rate...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos Particle Measuring Systems
-
Pharmabilities
9 Páginas
-
EL Capabilities
15 Páginas
-
BioCapt SU
8 Páginas
-
Lasair Pro Accessories and Parts Catalog
14 Páginas
-
Lasair III Accessories and Parts Catalog
13 Páginas
-
Pharmabilities Brochure
9 Páginas
-
UltraChem 40
2 Páginas
-
Lasair III Airborne Particle Counter
2 Páginas
-
MiniCapt Mobile
2 Páginas
-
Facility Pro
4 Páginas
-
AirNet II
2 Páginas
-
Ultra DI® 20
2 Páginas
-
HPD II High Pressure Diffuser
2 Páginas
-
HPD III High Pressure Diffuser
2 Páginas
-
Lasair® Pro Aerosol Particle Counter
2 Páginas
Catálogos arquivados
-
Lasair III Particle Counter
2 Páginas