Excertos do catálogo

Limit Touch Switch Object Actuates Switch and Turns Built-in Monitor Indicator ON • Instantaneous operation upon contact with extremely limited hysteresis for high-precision position detection. • Detects minute displacement or lightweight objects with minimal operating force. • Built-in LED indicator ensures easy operation monitoring. • DC models provide versatile functions in combination with the S3D2 Sensor Controller. Be sure to read Safety Precautions on page 6 to 7 and Safety Precautions for All Limit Switches. Application Examples · Detection of press completion position. · Detection of mistakes in workpiece setting or removal. · Detection of minute workpieces. · Drill positioning. · Material positioning. · Detection of workpiece edges. · Displacement detection and control. · Detection of paper or cloth edge (using indirect grounding). · Thickness control of rolling plates. Pressure NL Paper (cloth) NL Roller Ground side · Detection of paper or cloth seam (using indirect grounding). Controller Unit NL Controller Unit NL NL Grounding rod Paper (cloth)
Abrir o catálogo na página 1
NL Ordering Information Built-in Antenna Model Model Built-in antenna model · Provides sufficient OT (overtravel). Features · Antenna tip withstands bending. · Ensures high-precision positioning control. · OT of 5-mm max. (overtravel) Coil spring Power supply voltage Antenna only NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3) Note: Each model is provided with a standard 1-m cable. Separate Antenna Model Model Separate antenna model Features · Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used. No antenna Plunger with antenna...
Abrir o catálogo na página 2
NL Structure and Nomenclature Nomenclature Coil spring antenna Antenna assy Rubber packing Cover (not removable) Mounting hole (with mounting pitch conforming to DIN standards) Principle of Operation The Limit Touch Switch constantly emits a high frequency. If an object comes in touch with the touch antenna, .. Constants of the oscillation circuit will change and oscillation will stop. Switching circuit will operate and send out output signals. Applicable to a variety of purposes in combination with a dedicated sensor power supply. Feedback circuit Antenna Oscillation circuit Wave detection...
Abrir o catálogo na página 3
NL Connections Output Circuit Diagrams NL1 Black (White) Blue (Black) 4.7 kΩ Switch main circuit Switch main circuit Black Load (White) Output Blue (Black) Black Load (White) 100 VAC, 200 VAC Output Switch main circuit 0V Blue (Black) Note: The 0-V power supply side will be connected to the casing if the model is the NL1 or NL2. External Connection Sensor Power Supply (S3D2) The use of the S3D2 is recommended for supplying 12 VDC to the NL2 (or 24 VDC to the NL2) and converting the output of the NL into relay or open collector output in versatile timing control. The NL3 does not require a...
Abrir o catálogo na página 4
Built-in Antenna Models Coil Spring NL1-C NL2-C NL3-C *1. The stainless-steel plunger antenna allows a maximum OT (overtravel) of 5 mm. *2. This position is the FP (free position) of the plunger. *3. Use after removing the caution label. *1. The coil spring antenna is movable in any direction. Make sure that the angle of the antenna is within 30° to the FP (free position) after the antenna comes into contact with the object. *2. Use after removing the caution label. Note: 1. The force that pushes the actuator must not exceed 1.96 N. 2. The antenna is replaceable. Contact your OMRON...
Abrir o catálogo na página 5
NL Safety Precautions Refer to Safety Precautions for All Limit Switches. CAUTION Make sure that the antenna does not come into contact with the human body, otherwise an electric shock may be received. Precautions for Correct Use Antenna Grounded through Sensing Object • Grounded Object If the sensing object is the following grounded conductor, its size will not affect the operation of the NL. Check for the presence of insulators sticking to the sensing object or the corrosion of the sensing object, however, so that the ground resistance will not exceed 3 kΩ. Contact with Grounded Conductor...
Abrir o catálogo na página 6
If more than one NL is used in parallel or side-by-side, make sure that the distance between the antennas is at least 4 cm. 4 cm min. • Do not disassemble the NL, otherwise the internal wiring will be damaged and the NL will fail to operate. • Make sure that the conduit opening is free of foreign materials or cuttings. • The sealing of the NL uses nitrile butadiene rubber (NBR), which is highly oil resistive. If exposed to some types of oil or chemical indoors or outdoors, however, the NBR may deteriorate. Contact your OMRON representative for details. • Make sure that the load is connected...
Abrir o catálogo na página 7
Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER...
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos OMRON
-
Technical Explanation for Fiber Sensors
14 Páginas
-
D4F
8 Páginas
-
D4GS-N
11 Páginas
-
E4E2
5 Páginas
-
Smart Laser Sensors E3NC-L/E3NC-S
16 Páginas
-
Fiber SensorBest Selection Catalog
104 Páginas
-
Fiber Unit E32-LT/LD
4 Páginas
-
G9SE Series
20 Páginas
-
NX-SL/SI/SO
20 Páginas
-
G9SP
28 Páginas
-
G9SX-SM
24 Páginas
-
G9SX-SM/LM
9 Páginas
-
G9SX/G9SX-GS
49 Páginas
-
G9SX-LM
28 Páginas
-
G9SB
10 Páginas
-
G9SA
16 Páginas
-
DST1 Series
5 Páginas
-
WS02-CFSC1-E
3 Páginas
-
G9SA-300-SC
9 Páginas
-
K8AK-AS
12 Páginas
-
K8AK-AW
16 Páginas
-
K8AK-VS
12 Páginas
-
K8AK-VW
12 Páginas
-
K8AK-PH
12 Páginas
-
K8DS-PH
12 Páginas
-
K8AK-PM
16 Páginas
-
K8DS-PM
12 Páginas
-
K8AK-PA
12 Páginas
-
K8DS-PA
12 Páginas
-
K8AK-PW
12 Páginas
-
K8DS-PU
12 Páginas
-
K8DS-PZ
12 Páginas
-
K8AK-TS/PT
12 Páginas
-
K8AK-LS
12 Páginas
-
K8AK-TH
12 Páginas
-
K2CM
16 Páginas
-
SE
15 Páginas
-
SAO
13 Páginas
-
APR-S
6 Páginas
-
XS5
25 Páginas
-
XS2
29 Páginas
-
F92A
4 Páginas
-
GLS
3 Páginas
-
TL-L
5 Páginas
-
V680 series
68 Páginas
-
V680S Series
68 Páginas
-
MY
35 Páginas
-
Safety Light Curtain F3SG-R Series
80 Páginas
-
E3NC-L/-S
16 Páginas
-
61F-GPN-BT / -BC
5 Páginas
-
NE1A-SCPU Series
8 Páginas
-
NE1A-SCPU0[]-EIP
8 Páginas
-
NE0A-SCPU01
6 Páginas
-
LY
14 Páginas
-
G2R-[]-S
11 Páginas
-
G7T
7 Páginas
-
G2A
9 Páginas
-
G2A-434
7 Páginas
-
G2AK
7 Páginas
-
MK-S
9 Páginas
-
MK-S(X)
12 Páginas
-
MM
17 Páginas
-
MMK
14 Páginas
-
G4Q
6 Páginas
-
G7Z
9 Páginas
-
G7J
10 Páginas
-
E4B
12 Páginas
-
E4A-3K
9 Páginas
-
E4C-UDA
5 Páginas
-
E6H-C
5 Páginas
-
E6F-C
5 Páginas
-
E6D-C
5 Páginas
-
E6B2-C
5 Páginas
-
E6A2-C
5 Páginas
-
VB
5 Páginas
-
SC
5 Páginas
-
D5F
5 Páginas
-
D5A
8 Páginas
-
E3S-GS3E4
3 Páginas
-
E3S-R
11 Páginas
-
E3S-A
21 Páginas
-
E3S-CL
9 Páginas
-
E3ZM-C
14 Páginas
-
E3T Data Sheet
26 Páginas
-
E3T Series
6 Páginas
-
G5 Series
59 Páginas
-
Sysmac Catalog
410 Páginas
-
VT-X700
6 Páginas
-
E5AC-T
8 Páginas
-
CP1
12 Páginas
-
CP1E
12 Páginas
-
MS4800
40 Páginas
-
VC-DL100
6 Páginas
-
FZ4 Series
42 Páginas
-
ZG2
16 Páginas
-
ZS Series
32 Páginas
-
ZW Series
24 Páginas
-
E9NC-T
2 Páginas
-
Vision System FH series
54 Páginas
-
CompoNet
28 Páginas
-
F3SJ Series Safety Light Curtain
108 Páginas
-
Code Reader/OCR
24 Páginas
-
Fiber Sensor Best Selection Catalog
100 Páginas
-
Portable Multi-logger ZR-RX70
12 Páginas
-
Air Particle Sensor ZN-PD-S
2 Páginas
-
Smart Fiber Amplifier Units E3NX-FA
8 Páginas
-
NT series
18 Páginas
-
Programmable Controller SYSMAC CVM1
16 Páginas
-
Round Water-resistant Connectors
31 Páginas
-
Modular Temperature Controller EJ1
24 Páginas
-
Safety Controller G9SP
28 Páginas
-
E3FA PHOTOELECTRIC SENSORS
24 Páginas
-
Switch Mode Power Supply S8VK-G
22 Páginas
-
Data Logger ZR-RX Series
12 Páginas
-
Programmable Terminals NS Series
57 Páginas
-
DeviceNet Safety System
30 Páginas
-
Switching Power Supplies
16 Páginas
-
Photomicro Sensors
7 Páginas
-
Displacement Sensors
4 Páginas
-
R87F / R87T AC Axial Fans
28 Páginas
-
G9SX-GS Safety Guard Switching Unit
28 Páginas
-
H8PS Cam Positioner
32 Páginas
-
OS32C Safety Laser Scanner
24 Páginas
-
FQ Vision Sensor
17 Páginas
-
UM, MC3 Safety Mat/Safety Mat Controller
19 Páginas
-
ZN-PD Air Particle Sensor
16 Páginas
-
ZUV-C20H / C30H Smart Curing System
14 Páginas
-
E5CC Digital Temperature Controller
38 Páginas
-
S8EX Switch Mode Power Supply
24 Páginas
-
CP1L CP series CP1L CPU Unit
36 Páginas
-
E2EF
8 Páginas
-
FQ2 Smart camera
24 Páginas
Catálogos arquivados
-
SAFETY APPLICATION HANDBOOK
55 Páginas
-
SMART REMOTE I/O
12 Páginas
-
Sensor Accessories
38 Páginas
-
REGULATION SOLUTIONS
24 Páginas
-
Vision Systems
20 Páginas