Limit Touch Switch Object Actuates Switch and Turns Built-in Monitor Indicator ON • Instantaneous operation upon contact with extremely limited hysteresis for high-precision position detection. • Detects minute displacement or lightweight objects with minimal operating force. • Built-in LED indicator ensures easy operation monitoring. • DC models provide versatile functions in combination with the S3D2 Sensor Controller. Be sure to read Safety Precautions on page 6 to 7 and Safety Precautions for All Limit Switches. Application Examples · Detection of press completion position. · Detection of mistakes in workpiece setting or removal. · Detection of minute workpieces. · Drill positioning. · Material positioning. · Detection of workpiece edges. · Displacement detection and control. · Detection of paper or cloth edge (using indirect grounding). · Thickness control of rolling plates. Pressure NL Paper (cloth) NL Roller Ground side · Detection of paper or cloth seam (using indirect grounding). Controller Unit NL Controller Unit NL NL Grounding rod Paper (cloth)

Abrir o catálogo na página 1
NL - 2

NL Ordering Information Built-in Antenna Model Model Built-in antenna model · Provides sufficient OT (overtravel). Features · Antenna tip withstands bending. · Ensures high-precision positioning control. · OT of 5-mm max. (overtravel) Coil spring Power supply voltage Antenna only NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3) Note: Each model is provided with a standard 1-m cable. Separate Antenna Model Model Separate antenna model Features · Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used. No antenna Plunger with antenna...

Abrir o catálogo na página 2
NL - 3

NL Structure and Nomenclature Nomenclature Coil spring antenna Antenna assy Rubber packing Cover (not removable) Mounting hole (with mounting pitch conforming to DIN standards) Principle of Operation The Limit Touch Switch constantly emits a high frequency. If an object comes in touch with the touch antenna, .. Constants of the oscillation circuit will change and oscillation will stop. Switching circuit will operate and send out output signals. Applicable to a variety of purposes in combination with a dedicated sensor power supply. Feedback circuit Antenna Oscillation circuit Wave detection...

Abrir o catálogo na página 3
NL - 4

NL Connections Output Circuit Diagrams NL1 Black (White) Blue (Black) 4.7 kΩ Switch main circuit Switch main circuit Black Load (White) Output Blue (Black) Black Load (White) 100 VAC, 200 VAC Output Switch main circuit 0V Blue (Black) Note: The 0-V power supply side will be connected to the casing if the model is the NL1 or NL2. External Connection Sensor Power Supply (S3D2) The use of the S3D2 is recommended for supplying 12 VDC to the NL2 (or 24 VDC to the NL2) and converting the output of the NL into relay or open collector output in versatile timing control. The NL3 does not require a...

Abrir o catálogo na página 4
NL - 5

Built-in Antenna Models Coil Spring NL1-C NL2-C NL3-C *1. The stainless-steel plunger antenna allows a maximum OT (overtravel) of 5 mm. *2. This position is the FP (free position) of the plunger. *3. Use after removing the caution label. *1. The coil spring antenna is movable in any direction. Make sure that the angle of the antenna is within 30° to the FP (free position) after the antenna comes into contact with the object. *2. Use after removing the caution label. Note: 1. The force that pushes the actuator must not exceed 1.96 N. 2. The antenna is replaceable. Contact your OMRON...

Abrir o catálogo na página 5
NL - 6

NL Safety Precautions Refer to Safety Precautions for All Limit Switches. CAUTION Make sure that the antenna does not come into contact with the human body, otherwise an electric shock may be received. Precautions for Correct Use Antenna Grounded through Sensing Object • Grounded Object If the sensing object is the following grounded conductor, its size will not affect the operation of the NL. Check for the presence of insulators sticking to the sensing object or the corrosion of the sensing object, however, so that the ground resistance will not exceed 3 kΩ. Contact with Grounded Conductor...

Abrir o catálogo na página 6
NL - 7

If more than one NL is used in parallel or side-by-side, make sure that the distance between the antennas is at least 4 cm. 4 cm min. • Do not disassemble the NL, otherwise the internal wiring will be damaged and the NL will fail to operate. • Make sure that the conduit opening is free of foreign materials or cuttings. • The sealing of the NL uses nitrile butadiene rubber (NBR), which is highly oil resistive. If exposed to some types of oil or chemical indoors or outdoors, however, the NBR may deteriorate. Contact your OMRON representative for details. • Make sure that the load is connected...

Abrir o catálogo na página 7
NL - 8

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos OMRON

  1. D4F

    8 Páginas

  2. D4GS-N

    11 Páginas

  3. E4E2

    5 Páginas

  4. G9SE Series

    20 Páginas

  5. NX-SL/SI/SO

    20 Páginas

  6. G9SP

    28 Páginas

  7. G9SX-SM

    24 Páginas

  8. G9SX-SM/LM

    9 Páginas

  9. G9SX/G9SX-GS

    49 Páginas

  10. G9SX-LM

    28 Páginas

  11. G9SB

    10 Páginas

  12. G9SA

    16 Páginas

  13. DST1 Series

    5 Páginas

  14. WS02-CFSC1-E

    3 Páginas

  15. G9SA-300-SC

    9 Páginas

  16. K8AK-AS

    12 Páginas

  17. K8AK-AW

    16 Páginas

  18. K8AK-VS

    12 Páginas

  19. K8AK-VW

    12 Páginas

  20. K8AK-PH

    12 Páginas

  21. K8DS-PH

    12 Páginas

  22. K8AK-PM

    16 Páginas

  23. K8DS-PM

    12 Páginas

  24. K8AK-PA

    12 Páginas

  25. K8DS-PA

    12 Páginas

  26. K8AK-PW

    12 Páginas

  27. K8DS-PU

    12 Páginas

  28. K8DS-PZ

    12 Páginas

  29. K8AK-TS/PT

    12 Páginas

  30. K8AK-LS

    12 Páginas

  31. K8AK-TH

    12 Páginas

  32. K2CM

    16 Páginas

  33. SE

    15 Páginas

  34. SAO

    13 Páginas

  35. APR-S

    6 Páginas

  36. XS5

    25 Páginas

  37. XS2

    29 Páginas

  38. F92A

    4 Páginas

  39. GLS

    3 Páginas

  40. TL-L

    5 Páginas

  41. V680 series

    68 Páginas

  42. V680S Series

    68 Páginas

  43. MY

    35 Páginas

  44. E3NC-L/-S

    16 Páginas

  45. 61F-GPN-BT / -BC

    5 Páginas

  46. NE1A-SCPU Series

    8 Páginas

  47. NE1A-SCPU0[]-EIP

    8 Páginas

  48. NE0A-SCPU01

    6 Páginas

  49. LY

    14 Páginas

  50. G2R-[]-S

    11 Páginas

  51. G7T

    7 Páginas

  52. G2A

    9 Páginas

  53. G2A-434

    7 Páginas

  54. G2AK

    7 Páginas

  55. MK-S

    9 Páginas

  56. MK-S(X)

    12 Páginas

  57. MM

    17 Páginas

  58. MMK

    14 Páginas

  59. G4Q

    6 Páginas

  60. G7Z

    9 Páginas

  61. G7J

    10 Páginas

  62. E4B

    12 Páginas

  63. E4A-3K

    9 Páginas

  64. E4C-UDA

    5 Páginas

  65. E6H-C

    5 Páginas

  66. E6F-C

    5 Páginas

  67. E6D-C

    5 Páginas

  68. E6B2-C

    5 Páginas

  69. E6A2-C

    5 Páginas

  70. VB

    5 Páginas

  71. SC

    5 Páginas

  72. D5F

    5 Páginas

  73. D5A

    8 Páginas

  74. E3S-GS3E4

    3 Páginas

  75. E3S-R

    11 Páginas

  76. E3S-A

    21 Páginas

  77. E3S-CL

    9 Páginas

  78. E3ZM-C

    14 Páginas

  79. E3T Data Sheet

    26 Páginas

  80. E3T Series

    6 Páginas

  81. G5 Series

    59 Páginas

  82. Sysmac Catalog

    410 Páginas

  83. VT-X700

    6 Páginas

  84. E5AC-T

    8 Páginas

  85. CP1

    12 Páginas

  86. CP1E

    12 Páginas

  87. MS4800

    40 Páginas

  88. VC-DL100

    6 Páginas

  89. FZ4 Series

    42 Páginas

  90. ZG2

    16 Páginas

  91. ZS Series

    32 Páginas

  92. ZW Series

    24 Páginas

  93. E9NC-T

    2 Páginas

  94. CompoNet

    28 Páginas

  95. Code Reader/OCR

    24 Páginas

  96. NT series

    18 Páginas

  97. FQ Vision Sensor

    17 Páginas

  98. E2EF

    8 Páginas

  99. FQ2 Smart camera

    24 Páginas

Catálogos arquivados

  1. SMART REMOTE I/O

    12 Páginas

  2. Sensor Accessories

    38 Páginas

  3. Vision Systems

    20 Páginas