NE0A-SCPU01
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

NE0A-SCPU01 - 1

Safety Network Controller New Lineup for Safety Applications with Up to 12 Inputs • Circuits for the required safety category are easy to build. • The safety circuits you create can be registered as templates and reused, for easy standardization. • A wide range of TÜV-certified templates is also available. • The NE0A operating conditions can be monitored from a standard DeviceNet Master. • Network distribution is possible by combining with an NE1A Safety Controller. • ISO13849-1 (PLe) and IEC 61508 SIL3 certification. Ordering Information Name No. of I/O points Safety inputs Test outputs Safety outputs Unit version Safety Network Controllers 12 * 2 6 NE0A-SCPU01 Ver. 1.0 Note: 1. The standard NE0A Safety Network Controller is equipped with spring-cage terminal blocks, but screw terminal blocks are available if desired, e.g., to replace previous terminals. 2. Network Configurator version 2.1@ or higher must be used when using a NE0A-SCPU01 Safety Network Controller. * When using the NE0A-SCPU01 as a standalone Controller, one input each is required for the feedback input and manual restart. Specifications Certified Standards Certification body Specifications Standard Communications 11 to 25 VDC supplied via communicapower supply voltage tions connector Internal circuit power supply voltage (V0) *1 I/O power supply voltage (V1, V2) *1 Communications power supply Current Internal circoncuit power sumpsupply tion I/O power supply *2 Overvoltage category II Noise immunity Vibration resistance Shock resistance Mounting method Ambient operating temperature Ambient operating humidity Ambient storage tem−40 to 70°C perature Degree of protection *1. V0-G0: Internal control circuit V1-G1: For external input device, test output V2-G2: For external output device *2. Not including power consumption for external devices.

Abrir o catálogo na página 1
NE0A-SCPU01 - 2

NE0A-SCPU01 Safety Input Specifications Test Output Specifications Input type Output type 11 VDC min. between each terminal and ground 5 VDC max. between each terminal and ground Rated output current 1.2 V max. between each output terminal and V1 Input current Safety Output Specifications Output type Rated output current 1.2 V max. between each output terminal and V2 DeviceNet Communications Specifications Communications protocol DeviceNet compliant Connection form Multi-drop system and T-branch system can be combined (for trunk line and branch lines) Communications speed Communications...

Abrir o catálogo na página 2
NE0A-SCPU01 - 3

Functions The following function blocks are available for designing safety circuits with the NE0A-SCPU01. These function blocks can be selected and assembled using the interactive wizard format to efficiently design safety applications. Classification of function block for safety circuit designs Application The following six parts can be selected for use as safety input devices. For Category 3 or 4 compliance, the filter monitoring time between signals can also be adjusted with redundant wiring for the necessary safety devices. Function blocks for safety input devices and setting input...

Abrir o catálogo na página 3
NE0A-SCPU01 - 4

Internal Circuit Diagrams DC-DC Converter (Non-insulated) V+ DeviceNet Physical Layer G1 T0 T1 IN0 Safety Input Circuit Test Output Circuit Internal Circuit DC-DC Converter (Non-insulated) Safety Output Circuit Terminal name Description Power supply terminal for internal circuit (24 VDC) Power supply terminal for external input device and test output (24 VDC) Power supply terminal for external output device (24 VDC) Safety input terminal Terminals IN10 and IN11 are used only for connecting a reset switch or EDM feedback. Test output terminal Connected to IN0 to IN11 safety inputs. T0 and T1...

Abrir o catálogo na página 4
NE0A-SCPU01 - 5

Safety Precautions Refer to the "Safety Precautions for All CIP Safety on DeviceNet Systems" for precautions. Be sure to read the following user's manual for other details required for correct use of the Safety Network Controller. CIP Safety on DeviceNet Safety Network Controller NE0A Series User's Manual (Cat. No. Z916)

Abrir o catálogo na página 5
NE0A-SCPU01 - 6

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos OMRON

  1. D4F

    8 Páginas

  2. D4GS-N

    11 Páginas

  3. E4E2

    5 Páginas

  4. G9SE Series

    20 Páginas

  5. NX-SL/SI/SO

    20 Páginas

  6. G9SP

    28 Páginas

  7. G9SX-SM

    24 Páginas

  8. G9SX-SM/LM

    9 Páginas

  9. G9SX/G9SX-GS

    49 Páginas

  10. G9SX-LM

    28 Páginas

  11. G9SB

    10 Páginas

  12. G9SA

    16 Páginas

  13. DST1 Series

    5 Páginas

  14. WS02-CFSC1-E

    3 Páginas

  15. G9SA-300-SC

    9 Páginas

  16. K8AK-AS

    12 Páginas

  17. K8AK-AW

    16 Páginas

  18. K8AK-VS

    12 Páginas

  19. K8AK-VW

    12 Páginas

  20. K8AK-PH

    12 Páginas

  21. K8DS-PH

    12 Páginas

  22. K8AK-PM

    16 Páginas

  23. K8DS-PM

    12 Páginas

  24. K8AK-PA

    12 Páginas

  25. K8DS-PA

    12 Páginas

  26. K8AK-PW

    12 Páginas

  27. K8DS-PU

    12 Páginas

  28. K8DS-PZ

    12 Páginas

  29. K8AK-TS/PT

    12 Páginas

  30. K8AK-LS

    12 Páginas

  31. K8AK-TH

    12 Páginas

  32. K2CM

    16 Páginas

  33. SE

    15 Páginas

  34. SAO

    13 Páginas

  35. APR-S

    6 Páginas

  36. XS5

    25 Páginas

  37. XS2

    29 Páginas

  38. F92A

    4 Páginas

  39. GLS

    3 Páginas

  40. TL-L

    5 Páginas

  41. V680 series

    68 Páginas

  42. V680S Series

    68 Páginas

  43. MY

    35 Páginas

  44. E3NC-L/-S

    16 Páginas

  45. 61F-GPN-BT / -BC

    5 Páginas

  46. NE1A-SCPU Series

    8 Páginas

  47. NE1A-SCPU0[]-EIP

    8 Páginas

  48. LY

    14 Páginas

  49. G2R-[]-S

    11 Páginas

  50. G7T

    7 Páginas

  51. G2A

    9 Páginas

  52. G2A-434

    7 Páginas

  53. G2AK

    7 Páginas

  54. MK-S

    9 Páginas

  55. MK-S(X)

    12 Páginas

  56. MM

    17 Páginas

  57. MMK

    14 Páginas

  58. G4Q

    6 Páginas

  59. G7Z

    9 Páginas

  60. G7J

    10 Páginas

  61. E4B

    12 Páginas

  62. E4A-3K

    9 Páginas

  63. E4C-UDA

    5 Páginas

  64. E6H-C

    5 Páginas

  65. E6F-C

    5 Páginas

  66. E6D-C

    5 Páginas

  67. E6B2-C

    5 Páginas

  68. E6A2-C

    5 Páginas

  69. NL

    8 Páginas

  70. VB

    5 Páginas

  71. SC

    5 Páginas

  72. D5F

    5 Páginas

  73. D5A

    8 Páginas

  74. E3S-GS3E4

    3 Páginas

  75. E3S-R

    11 Páginas

  76. E3S-A

    21 Páginas

  77. E3S-CL

    9 Páginas

  78. E3ZM-C

    14 Páginas

  79. E3T Data Sheet

    26 Páginas

  80. E3T Series

    6 Páginas

  81. G5 Series

    59 Páginas

  82. Sysmac Catalog

    410 Páginas

  83. VT-X700

    6 Páginas

  84. E5AC-T

    8 Páginas

  85. CP1

    12 Páginas

  86. CP1E

    12 Páginas

  87. MS4800

    40 Páginas

  88. VC-DL100

    6 Páginas

  89. FZ4 Series

    42 Páginas

  90. ZG2

    16 Páginas

  91. ZS Series

    32 Páginas

  92. ZW Series

    24 Páginas

  93. E9NC-T

    2 Páginas

  94. CompoNet

    28 Páginas

  95. Code Reader/OCR

    24 Páginas

  96. NT series

    18 Páginas

  97. FQ Vision Sensor

    17 Páginas

  98. E2EF

    8 Páginas

  99. FQ2 Smart camera

    24 Páginas

Catálogos arquivados

  1. SMART REMOTE I/O

    12 Páginas

  2. Sensor Accessories

    38 Páginas

  3. Vision Systems

    20 Páginas