Excertos do catálogo

Compact Non-Contact Door Switch/Non-Contact Door Switch Controller D40A/G9SX-NS Electronic Detection Mechanism for Better Stability in Non-contact Door Switch Operation Connection is also possible to a G9SP Safety Controller. •Complies with ISO 13849-1(PLd/Safety Category 3). •The maximum number of Switches that can be connected to a G9SPseries Controller is given below. G9SP-N10S: 15 × 1 system G9SP-N10D/20S: 15 × 2 system For details, refer to the G9SP Series Operation Manual (Cat. No.Z922). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Be sure to read the “Safety Precautions” on page 28 and the “Precautions for All Safety Door Switches”. Features ● Easy-to-see 2-Color Indicators ● Mount from Either Side Switch status is easy to see at a glance with these red/yellow LED indicators. Red: Open door detected. Yellow: Closed door detected. Not lit: Power OFF or failure Swinging doors ● Small Actuator Sliding doors ● Save Labor with Connector and Reduce Inventory An actuator that is smaller than the switch saves space, even inside the door. Even when mounted with an L-bracket, the actuator's height will not hinder installation or operation. Compact Switch Mount from whichever side provides the easiest wiring path to enable mounting to all types of doors. Wiring time can be reduced with the connector. Cable lengths can be selected, and only cables of required lengths can be purchased. Switches can be integrated into a single Switch with a connector when installing in a machine with multiple doors or various types of machines, which can reduce inventory. Actuator ● Connect Up to 30 Switches to a Single Controller Reduce costs by connecting up to 30 Switches to a single Controller. Up to 30 Switches 1
Abrir o catálogo na página 1
D40A/G9SX-NS Solves Conventional Switch Issues to Provide Stable Detection Issue 1 The Switch does not accurately detect the door when it is closed slowly, resulting in an error. Conventional switch An error can occur if the door is closed slowly with conventional switches. Door closed slowly. Solution 1 Conventional Switches The D40A does not use reed switches and provides stable detection with electronic switches. Slow Slow Magnet Magnet Reed switch contacts Reed switch contacts Error Issue 2 If the switching timing of reed switch contacts 1 and 2 varies too much, the Controller detects...
Abrir o catálogo na página 2
D40A/G9SX-NS Two Types of Controller to Solve Productivity, Expandability, and Maintenance Issues The G9SX-NS and G9SX-NSA are designed specifically for use with Non-contact door switch, and with the G9SX-NSA you can also connect mechanical safety door switches. Among other features, these Controllers support logical AND connections that enable partial stops. These Controllers make the most of D40A Switches. ● Two Different Controllers G9SX-NS G9SX-NSA @Logical AND connection input @Logical AND connection input @D40A input @D40A plus mechanical safety door switch input, channel 1 or 2 @Two...
Abrir o catálogo na página 3
D40A/G9SX-NS Reduce Costs with these New-Concept Controllers Issue 1 Two Controllers are required for emergency stop switches and non-contact door switches. Application ●One hazard. ●The system must be stopped when either a door is opened or an emergency stop switch is pressed. D40B Emergency stop switch * D40A Solution 1 D40B-J1 Emergency stop switch * The D40A Simplifies the Configuration The G9SA must be added to connect the G9SA emergency stop switch. Two Controllers Issue 2 G9SX-NSA With only one G9SX-NSA222-T03@ Controller, both a Non-contact Door Switch and an emergency stop switch...
Abrir o catálogo na página 4
D40A/G9SX-NS Selection of Safety Controllers for D40A [Connectable Controllers] Safety Controller G9SP Non-contact Door Switch Controller G9SX-NS Safety Controller G9SP Non-contact Door Switch Controller G9SX-NS • Flexible programming by combining function blocks • Extensive system configurations • Decreased work hours by convenient configurator • Easy expansion of output points by an expansion unit • Improved maintainability by LED display • No special programming required Function Blocks Note: For product information, refer to the website at: http://www.ia.omron.com/ Model Number...
Abrir o catálogo na página 5
D40A/G9SX-NS Ordering Information List of Models Non-Contact Door Switches (Switch/Actuator) Classification Appearance Auxiliary outputs Cable length Model 2m D40A-1C2 5m D40A-1C5 Standard models Semiconductor outputs * Connector model 0.15 m D40A-1C015-F * PNP open-collector semiconductor output. Cable with connector Connector Type Cable Length Packing Unit 2m XS2F-D521-DG0-A 5m XS2F-D521-GG0-A 10 m XS2F-D521-JG0-A 1 15 m XS2F-D521-KG0-A 1 20 m Single-end Model XS2F-D521-LG0-A Connector Type Cable Length Model Packing Unit 5 2m XS2W-D521-DG1-A 5 5 5m XS2W-D521-GG1-A 5 10 m XS2W-D521-JG1-A...
Abrir o catálogo na página 6
D40A/G9SX-NS Accessories Terminal Block Appearance * Specifications Applicable units Model Remarks Terminal Block with screw terminals (3-pin) G9SX-NSA Y9S-03T1B-02A Two Terminal Blocks (black) with screw terminals, and a set of six code marks to prevent erroneous insertion. Terminal Block with screw terminals (4-pin) G9SX-NS G9SX-EX-@ Y9S-04T1B-02A Two Terminal Blocks (black) with screw terminals, and a set of six code marks to prevent erroneous insertion. Terminal Block with springG9SX-NSA cage terminals (3-pin) Y9S-03C1B-02A Two Terminal Blocks (black) with spring-cage terminals, and a...
Abrir o catálogo na página 7
D40A/G9SX-NS Non-contact Door Switches Ratings Power input Item Model G9SX-NS202-@ G9SX-NSA222-T03-@ Rated supply voltage Operating voltage range −15% to 10% of rated supply voltage Rated power consumption * 3 W max. G9SX-EX-@ 24 V DC 4 W max. 2 W max. * Power consumption of loads not included. Inputs Item Model Safety input *1 G9SX-NS202-@/G9SX-NSA222-T03-@ Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ *2 Feedback/reset input *1. Only applies to the G9SX-NSA222-T03-@. Refers to input other than that from the Non-contact Door Switch. *2. Provide a current equal...
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos OMRON
-
Technical Explanation for Fiber Sensors
14 Páginas
-
D4F
8 Páginas
-
D4GS-N
11 Páginas
-
E4E2
5 Páginas
-
Smart Laser Sensors E3NC-L/E3NC-S
16 Páginas
-
Fiber SensorBest Selection Catalog
104 Páginas
-
Fiber Unit E32-LT/LD
4 Páginas
-
G9SE Series
20 Páginas
-
NX-SL/SI/SO
20 Páginas
-
G9SP
28 Páginas
-
G9SX-SM
24 Páginas
-
G9SX-SM/LM
9 Páginas
-
G9SX/G9SX-GS
49 Páginas
-
G9SX-LM
28 Páginas
-
G9SB
10 Páginas
-
G9SA
16 Páginas
-
DST1 Series
5 Páginas
-
WS02-CFSC1-E
3 Páginas
-
G9SA-300-SC
9 Páginas
-
K8AK-AS
12 Páginas
-
K8AK-AW
16 Páginas
-
K8AK-VS
12 Páginas
-
K8AK-VW
12 Páginas
-
K8AK-PH
12 Páginas
-
K8DS-PH
12 Páginas
-
K8AK-PM
16 Páginas
-
K8DS-PM
12 Páginas
-
K8AK-PA
12 Páginas
-
K8DS-PA
12 Páginas
-
K8AK-PW
12 Páginas
-
K8DS-PU
12 Páginas
-
K8DS-PZ
12 Páginas
-
K8AK-TS/PT
12 Páginas
-
K8AK-LS
12 Páginas
-
K8AK-TH
12 Páginas
-
K2CM
16 Páginas
-
SE
15 Páginas
-
SAO
13 Páginas
-
APR-S
6 Páginas
-
XS5
25 Páginas
-
XS2
29 Páginas
-
F92A
4 Páginas
-
GLS
3 Páginas
-
TL-L
5 Páginas
-
V680 series
68 Páginas
-
V680S Series
68 Páginas
-
MY
35 Páginas
-
Safety Light Curtain F3SG-R Series
80 Páginas
-
E3NC-L/-S
16 Páginas
-
61F-GPN-BT / -BC
5 Páginas
-
NE1A-SCPU Series
8 Páginas
-
NE1A-SCPU0[]-EIP
8 Páginas
-
NE0A-SCPU01
6 Páginas
-
LY
14 Páginas
-
G2R-[]-S
11 Páginas
-
G7T
7 Páginas
-
G2A
9 Páginas
-
G2A-434
7 Páginas
-
G2AK
7 Páginas
-
MK-S
9 Páginas
-
MK-S(X)
12 Páginas
-
MM
17 Páginas
-
MMK
14 Páginas
-
G4Q
6 Páginas
-
G7Z
9 Páginas
-
G7J
10 Páginas
-
E4B
12 Páginas
-
E4A-3K
9 Páginas
-
E4C-UDA
5 Páginas
-
E6H-C
5 Páginas
-
E6F-C
5 Páginas
-
E6D-C
5 Páginas
-
E6B2-C
5 Páginas
-
E6A2-C
5 Páginas
-
NL
8 Páginas
-
VB
5 Páginas
-
SC
5 Páginas
-
D5F
5 Páginas
-
D5A
8 Páginas
-
E3S-GS3E4
3 Páginas
-
E3S-R
11 Páginas
-
E3S-A
21 Páginas
-
E3S-CL
9 Páginas
-
E3ZM-C
14 Páginas
-
E3T Data Sheet
26 Páginas
-
E3T Series
6 Páginas
-
G5 Series
59 Páginas
-
Sysmac Catalog
410 Páginas
-
VT-X700
6 Páginas
-
E5AC-T
8 Páginas
-
CP1
12 Páginas
-
CP1E
12 Páginas
-
MS4800
40 Páginas
-
VC-DL100
6 Páginas
-
FZ4 Series
42 Páginas
-
ZG2
16 Páginas
-
ZS Series
32 Páginas
-
ZW Series
24 Páginas
-
E9NC-T
2 Páginas
-
Vision System FH series
54 Páginas
-
CompoNet
28 Páginas
-
F3SJ Series Safety Light Curtain
108 Páginas
-
Code Reader/OCR
24 Páginas
-
Fiber Sensor Best Selection Catalog
100 Páginas
-
Portable Multi-logger ZR-RX70
12 Páginas
-
Air Particle Sensor ZN-PD-S
2 Páginas
-
Smart Fiber Amplifier Units E3NX-FA
8 Páginas
-
NT series
18 Páginas
-
Programmable Controller SYSMAC CVM1
16 Páginas
-
Round Water-resistant Connectors
31 Páginas
-
Modular Temperature Controller EJ1
24 Páginas
-
Safety Controller G9SP
28 Páginas
-
E3FA PHOTOELECTRIC SENSORS
24 Páginas
-
Switch Mode Power Supply S8VK-G
22 Páginas
-
Data Logger ZR-RX Series
12 Páginas
-
Programmable Terminals NS Series
57 Páginas
-
DeviceNet Safety System
30 Páginas
-
Switching Power Supplies
16 Páginas
-
Photomicro Sensors
7 Páginas
-
Displacement Sensors
4 Páginas
-
R87F / R87T AC Axial Fans
28 Páginas
-
G9SX-GS Safety Guard Switching Unit
28 Páginas
-
H8PS Cam Positioner
32 Páginas
-
OS32C Safety Laser Scanner
24 Páginas
-
FQ Vision Sensor
17 Páginas
-
UM, MC3 Safety Mat/Safety Mat Controller
19 Páginas
-
ZN-PD Air Particle Sensor
16 Páginas
-
ZUV-C20H / C30H Smart Curing System
14 Páginas
-
E5CC Digital Temperature Controller
38 Páginas
-
S8EX Switch Mode Power Supply
24 Páginas
-
CP1L CP series CP1L CPU Unit
36 Páginas
-
E2EF
8 Páginas
-
FQ2 Smart camera
24 Páginas
Catálogos arquivados
-
SAFETY APPLICATION HANDBOOK
55 Páginas
-
SMART REMOTE I/O
12 Páginas
-
Sensor Accessories
38 Páginas
-
REGULATION SOLUTIONS
24 Páginas
-
Vision Systems
20 Páginas