Excertos do catálogo

Conductive Level Controller Battery (24 VDC) allows use in locations without AC power supply. AC sine-wave voltage between electrodes enables stable detection with no electric corrosion. • Outputs can be set to self-hold at ON or OFF using special circuits. • Adjustable sensitivity, with an operating resistance range of 0 to 100 kΩ, allows use for a wide variety of liquids. • Relay contact chattering conventionally caused by waves eliminated using open collector output, reducing contact wear. • Meets CE marking and is a UL recognized component. Refer to Safety Precautions for Floatless Level Controllers. Features The 61F can now run on DC power to allow energy savings, greater safety, and use in emergency situations. Combines DC Power Supply with AC Sensing Method AC sine-wave signals are sent to electrodes using a built-in DC-AC converter, preventing electric corrosion and ensuring safety. Supports Multi-channel Sensing Power supply circuits and detection circuits are isolated, allowing more than one Controller to be used in the same tank. Open Collector Output Signals can be used as direct input for a PLC. PNP output is also possible using the connection method. Oscillator circuit Detector circuit Upper limit Mid-point Control output is possible for upper limit, mid-point, and lower limit. Lower limit Same Wiring for Supply and Drainage Supply control and drainage control can be performed with the same wiring (short terminals 7 and 8 for supply control). This makes it easy to perform wiring and confirm connection. Chattering Load Drainage control Supply control Short-circuit Ordering Information Product name Conductive Level Controller Relay contact (SPST-NO) Front Socket Electrode Holder Note: A variety of Holders are available to suit different types of application. For details, refer to 61F Floatless Level Controller (F030-E1-8).
Abrir o catálogo na página 1
Specifications ■ Ratings 61F-GPN-BT Rated voltage Allowable voltage range Interelectrode voltage Operation resistance (See note 1.) Release resistance Switching between supply and drainage Terminals 7 and 8 open: Automatic drainage operation Terminals 7 and 8 shorted: Automatic supply operation Output specifications Open collector (NPN) 30 VDC, 100 mA max. Leak current: 100 μA max. Relay output, SPST-NO 5 A, 240 VAC (Resistive load) 5 A, 30 VDC Life expectancy Electrical: 100,000 operations min. Mechanical: 20,000,000 operations min. Wiring distance (See note 2.) Note: 1. The 61F may not...
Abrir o catálogo na página 2
61F-GPN-BT/-BC ■ Reading Signals for the Liquid Level Only (No Control) Only E1 and E3 are used. Output will turn ON when the liquid level reaches E1 if terminals 7 and 8 are open, and will turn OFF if terminals 7 and 8 are closed. Also, to take signals for liquid level at several points, use terminal 4 as a common for all of the Controllers and use terminal 5 of each Controller as an electrode. Note: If terminals 7 and 8 are shorted, operation of the 61F relay is “de-energizing” (i.e., energized normally and de-energized when liquid is present across the electrodes). Therefore, if the...
Abrir o catálogo na página 3
Safety Precautions Refer to Safety Precautions for Floatless Level Controllers. General Precautions Before using the Controller under conditions not described in the relevant documents or applying the Controller to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the Controller are...
Abrir o catálogo na página 4
Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...
Abrir o catálogo na página 5Todos os catálogos e folhetos técnicos OMRON
-
Technical Explanation for Fiber Sensors
14 Páginas
-
D4F
8 Páginas
-
D4GS-N
11 Páginas
-
E4E2
5 Páginas
-
Smart Laser Sensors E3NC-L/E3NC-S
16 Páginas
-
Fiber SensorBest Selection Catalog
104 Páginas
-
Fiber Unit E32-LT/LD
4 Páginas
-
G9SE Series
20 Páginas
-
NX-SL/SI/SO
20 Páginas
-
G9SP
28 Páginas
-
G9SX-SM
24 Páginas
-
G9SX-SM/LM
9 Páginas
-
G9SX/G9SX-GS
49 Páginas
-
G9SX-LM
28 Páginas
-
G9SB
10 Páginas
-
G9SA
16 Páginas
-
DST1 Series
5 Páginas
-
WS02-CFSC1-E
3 Páginas
-
G9SA-300-SC
9 Páginas
-
K8AK-AS
12 Páginas
-
K8AK-AW
16 Páginas
-
K8AK-VS
12 Páginas
-
K8AK-VW
12 Páginas
-
K8AK-PH
12 Páginas
-
K8DS-PH
12 Páginas
-
K8AK-PM
16 Páginas
-
K8DS-PM
12 Páginas
-
K8AK-PA
12 Páginas
-
K8DS-PA
12 Páginas
-
K8AK-PW
12 Páginas
-
K8DS-PU
12 Páginas
-
K8DS-PZ
12 Páginas
-
K8AK-TS/PT
12 Páginas
-
K8AK-LS
12 Páginas
-
K8AK-TH
12 Páginas
-
K2CM
16 Páginas
-
SE
15 Páginas
-
SAO
13 Páginas
-
APR-S
6 Páginas
-
XS5
25 Páginas
-
XS2
29 Páginas
-
F92A
4 Páginas
-
GLS
3 Páginas
-
TL-L
5 Páginas
-
V680 series
68 Páginas
-
V680S Series
68 Páginas
-
MY
35 Páginas
-
Safety Light Curtain F3SG-R Series
80 Páginas
-
E3NC-L/-S
16 Páginas
-
NE1A-SCPU Series
8 Páginas
-
NE1A-SCPU0[]-EIP
8 Páginas
-
NE0A-SCPU01
6 Páginas
-
LY
14 Páginas
-
G2R-[]-S
11 Páginas
-
G7T
7 Páginas
-
G2A
9 Páginas
-
G2A-434
7 Páginas
-
G2AK
7 Páginas
-
MK-S
9 Páginas
-
MK-S(X)
12 Páginas
-
MM
17 Páginas
-
MMK
14 Páginas
-
G4Q
6 Páginas
-
G7Z
9 Páginas
-
G7J
10 Páginas
-
E4B
12 Páginas
-
E4A-3K
9 Páginas
-
E4C-UDA
5 Páginas
-
E6H-C
5 Páginas
-
E6F-C
5 Páginas
-
E6D-C
5 Páginas
-
E6B2-C
5 Páginas
-
E6A2-C
5 Páginas
-
NL
8 Páginas
-
VB
5 Páginas
-
SC
5 Páginas
-
D5F
5 Páginas
-
D5A
8 Páginas
-
E3S-GS3E4
3 Páginas
-
E3S-R
11 Páginas
-
E3S-A
21 Páginas
-
E3S-CL
9 Páginas
-
E3ZM-C
14 Páginas
-
E3T Data Sheet
26 Páginas
-
E3T Series
6 Páginas
-
G5 Series
59 Páginas
-
Sysmac Catalog
410 Páginas
-
VT-X700
6 Páginas
-
E5AC-T
8 Páginas
-
CP1
12 Páginas
-
CP1E
12 Páginas
-
MS4800
40 Páginas
-
VC-DL100
6 Páginas
-
FZ4 Series
42 Páginas
-
ZG2
16 Páginas
-
ZS Series
32 Páginas
-
ZW Series
24 Páginas
-
E9NC-T
2 Páginas
-
Vision System FH series
54 Páginas
-
CompoNet
28 Páginas
-
F3SJ Series Safety Light Curtain
108 Páginas
-
Code Reader/OCR
24 Páginas
-
Fiber Sensor Best Selection Catalog
100 Páginas
-
Portable Multi-logger ZR-RX70
12 Páginas
-
Air Particle Sensor ZN-PD-S
2 Páginas
-
Smart Fiber Amplifier Units E3NX-FA
8 Páginas
-
NT series
18 Páginas
-
Programmable Controller SYSMAC CVM1
16 Páginas
-
Round Water-resistant Connectors
31 Páginas
-
Modular Temperature Controller EJ1
24 Páginas
-
Safety Controller G9SP
28 Páginas
-
E3FA PHOTOELECTRIC SENSORS
24 Páginas
-
Switch Mode Power Supply S8VK-G
22 Páginas
-
Data Logger ZR-RX Series
12 Páginas
-
Programmable Terminals NS Series
57 Páginas
-
DeviceNet Safety System
30 Páginas
-
Switching Power Supplies
16 Páginas
-
Photomicro Sensors
7 Páginas
-
Displacement Sensors
4 Páginas
-
R87F / R87T AC Axial Fans
28 Páginas
-
G9SX-GS Safety Guard Switching Unit
28 Páginas
-
H8PS Cam Positioner
32 Páginas
-
OS32C Safety Laser Scanner
24 Páginas
-
FQ Vision Sensor
17 Páginas
-
UM, MC3 Safety Mat/Safety Mat Controller
19 Páginas
-
ZN-PD Air Particle Sensor
16 Páginas
-
ZUV-C20H / C30H Smart Curing System
14 Páginas
-
E5CC Digital Temperature Controller
38 Páginas
-
S8EX Switch Mode Power Supply
24 Páginas
-
CP1L CP series CP1L CPU Unit
36 Páginas
-
E2EF
8 Páginas
-
FQ2 Smart camera
24 Páginas
Catálogos arquivados
-
SAFETY APPLICATION HANDBOOK
55 Páginas
-
SMART REMOTE I/O
12 Páginas
-
Sensor Accessories
38 Páginas
-
REGULATION SOLUTIONS
24 Páginas
-
Vision Systems
20 Páginas