61F-GPN-BT / -BC
1 / 5Páginas

Excertos do catálogo

61F-GPN-BT / -BC - 1

Conductive Level Controller Battery (24 VDC) allows use in locations without AC power supply. AC sine-wave voltage between electrodes enables stable detection with no electric corrosion. • Outputs can be set to self-hold at ON or OFF using special circuits. • Adjustable sensitivity, with an operating resistance range of 0 to 100 kΩ, allows use for a wide variety of liquids. • Relay contact chattering conventionally caused by waves eliminated using open collector output, reducing contact wear. • Meets CE marking and is a UL recognized component. Refer to Safety Precautions for Floatless Level Controllers. Features The 61F can now run on DC power to allow energy savings, greater safety, and use in emergency situations. Combines DC Power Supply with AC Sensing Method AC sine-wave signals are sent to electrodes using a built-in DC-AC converter, preventing electric corrosion and ensuring safety. Supports Multi-channel Sensing Power supply circuits and detection circuits are isolated, allowing more than one Controller to be used in the same tank. Open Collector Output Signals can be used as direct input for a PLC. PNP output is also possible using the connection method. Oscillator circuit Detector circuit Upper limit Mid-point Control output is possible for upper limit, mid-point, and lower limit. Lower limit Same Wiring for Supply and Drainage Supply control and drainage control can be performed with the same wiring (short terminals 7 and 8 for supply control). This makes it easy to perform wiring and confirm connection. Chattering Load Drainage control Supply control Short-circuit Ordering Information Product name Conductive Level Controller Relay contact (SPST-NO) Front Socket Electrode Holder Note: A variety of Holders are available to suit different types of application. For details, refer to 61F Floatless Level Controller (F030-E1-8).

Abrir o catálogo na página 1
61F-GPN-BT / -BC - 2

Specifications ■ Ratings 61F-GPN-BT Rated voltage Allowable voltage range Interelectrode voltage Operation resistance (See note 1.) Release resistance Switching between supply and drainage Terminals 7 and 8 open: Automatic drainage operation Terminals 7 and 8 shorted: Automatic supply operation Output specifications Open collector (NPN) 30 VDC, 100 mA max. Leak current: 100 μA max. Relay output, SPST-NO 5 A, 240 VAC (Resistive load) 5 A, 30 VDC Life expectancy Electrical: 100,000 operations min. Mechanical: 20,000,000 operations min. Wiring distance (See note 2.) Note: 1. The 61F may not...

Abrir o catálogo na página 2
61F-GPN-BT / -BC - 3

61F-GPN-BT/-BC ■ Reading Signals for the Liquid Level Only (No Control) Only E1 and E3 are used. Output will turn ON when the liquid level reaches E1 if terminals 7 and 8 are open, and will turn OFF if terminals 7 and 8 are closed. Also, to take signals for liquid level at several points, use terminal 4 as a common for all of the Controllers and use terminal 5 of each Controller as an electrode. Note: If terminals 7 and 8 are shorted, operation of the 61F relay is “de-energizing” (i.e., energized normally and de-energized when liquid is present across the electrodes). Therefore, if the...

Abrir o catálogo na página 3
61F-GPN-BT / -BC - 4

Safety Precautions Refer to Safety Precautions for Floatless Level Controllers. General Precautions Before using the Controller under conditions not described in the relevant documents or applying the Controller to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment and other systems, machines, and equipment that may have a serious influence on lives and property if used improperly, consult your OMRON representative. Make sure that the ratings and performance characteristics of the Controller are...

Abrir o catálogo na página 4
61F-GPN-BT / -BC - 5

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS...

Abrir o catálogo na página 5

Todos os catálogos e folhetos técnicos OMRON

  1. D4F

    8 Páginas

  2. D4GS-N

    11 Páginas

  3. E4E2

    5 Páginas

  4. G9SE Series

    20 Páginas

  5. NX-SL/SI/SO

    20 Páginas

  6. G9SP

    28 Páginas

  7. G9SX-SM

    24 Páginas

  8. G9SX-SM/LM

    9 Páginas

  9. G9SX/G9SX-GS

    49 Páginas

  10. G9SX-LM

    28 Páginas

  11. G9SB

    10 Páginas

  12. G9SA

    16 Páginas

  13. DST1 Series

    5 Páginas

  14. WS02-CFSC1-E

    3 Páginas

  15. G9SA-300-SC

    9 Páginas

  16. K8AK-AS

    12 Páginas

  17. K8AK-AW

    16 Páginas

  18. K8AK-VS

    12 Páginas

  19. K8AK-VW

    12 Páginas

  20. K8AK-PH

    12 Páginas

  21. K8DS-PH

    12 Páginas

  22. K8AK-PM

    16 Páginas

  23. K8DS-PM

    12 Páginas

  24. K8AK-PA

    12 Páginas

  25. K8DS-PA

    12 Páginas

  26. K8AK-PW

    12 Páginas

  27. K8DS-PU

    12 Páginas

  28. K8DS-PZ

    12 Páginas

  29. K8AK-TS/PT

    12 Páginas

  30. K8AK-LS

    12 Páginas

  31. K8AK-TH

    12 Páginas

  32. K2CM

    16 Páginas

  33. SE

    15 Páginas

  34. SAO

    13 Páginas

  35. APR-S

    6 Páginas

  36. XS5

    25 Páginas

  37. XS2

    29 Páginas

  38. F92A

    4 Páginas

  39. GLS

    3 Páginas

  40. TL-L

    5 Páginas

  41. V680 series

    68 Páginas

  42. V680S Series

    68 Páginas

  43. MY

    35 Páginas

  44. E3NC-L/-S

    16 Páginas

  45. NE1A-SCPU Series

    8 Páginas

  46. NE1A-SCPU0[]-EIP

    8 Páginas

  47. NE0A-SCPU01

    6 Páginas

  48. LY

    14 Páginas

  49. G2R-[]-S

    11 Páginas

  50. G7T

    7 Páginas

  51. G2A

    9 Páginas

  52. G2A-434

    7 Páginas

  53. G2AK

    7 Páginas

  54. MK-S

    9 Páginas

  55. MK-S(X)

    12 Páginas

  56. MM

    17 Páginas

  57. MMK

    14 Páginas

  58. G4Q

    6 Páginas

  59. G7Z

    9 Páginas

  60. G7J

    10 Páginas

  61. E4B

    12 Páginas

  62. E4A-3K

    9 Páginas

  63. E4C-UDA

    5 Páginas

  64. E6H-C

    5 Páginas

  65. E6F-C

    5 Páginas

  66. E6D-C

    5 Páginas

  67. E6B2-C

    5 Páginas

  68. E6A2-C

    5 Páginas

  69. NL

    8 Páginas

  70. VB

    5 Páginas

  71. SC

    5 Páginas

  72. D5F

    5 Páginas

  73. D5A

    8 Páginas

  74. E3S-GS3E4

    3 Páginas

  75. E3S-R

    11 Páginas

  76. E3S-A

    21 Páginas

  77. E3S-CL

    9 Páginas

  78. E3ZM-C

    14 Páginas

  79. E3T Data Sheet

    26 Páginas

  80. E3T Series

    6 Páginas

  81. G5 Series

    59 Páginas

  82. Sysmac Catalog

    410 Páginas

  83. VT-X700

    6 Páginas

  84. E5AC-T

    8 Páginas

  85. CP1

    12 Páginas

  86. CP1E

    12 Páginas

  87. MS4800

    40 Páginas

  88. VC-DL100

    6 Páginas

  89. FZ4 Series

    42 Páginas

  90. ZG2

    16 Páginas

  91. ZS Series

    32 Páginas

  92. ZW Series

    24 Páginas

  93. E9NC-T

    2 Páginas

  94. CompoNet

    28 Páginas

  95. Code Reader/OCR

    24 Páginas

  96. NT series

    18 Páginas

  97. FQ Vision Sensor

    17 Páginas

  98. E2EF

    8 Páginas

  99. FQ2 Smart camera

    24 Páginas

Catálogos arquivados

  1. SMART REMOTE I/O

    12 Páginas

  2. Sensor Accessories

    38 Páginas

  3. Vision Systems

    20 Páginas