Next Generation Signal Conditioners - 1

Reliable Signal Conditioning Solutions with reduced Total Cost of Ownership >

Abrir o catálogo na página 1
Next Generation Signal Conditioners - 2

a name synonymous with qualityOMNIFLEX has been designing and manufacturing electronic products and systems for the automation and control industry since 1965. Through our world-wide partner network, we specialise in providing solutions to industry in the fields of Remote I/O, RTUs, Data Acquisition, Alarm and Events management, and Process Signal Conditioning Systems. More than 3 decades of experience in innovating products and systems such as these have resulted in a refined range of products and solutions being relied upon every hour of every day by major corporations round the world. >...

Abrir o catálogo na página 2
Next Generation Signal Conditioners - 3

Thermocouples dc voltage Resistance (RTDs) dc current milliVolts ac voltage Frequency ac current > dc Voltage (bipolar) Pulses dc Current (bipolar) >

Abrir o catálogo na página 3
Next Generation Signal Conditioners - 4

Model C2063 Model C2462 Model C2463 Model C2464 > Application Application Application Application Use the LPI loop powered isolator to remove ground loops in 4-20mA current loops where power is unavailable and there is sufficient spare volt drop in the loop to accommo-date the insertion loss. Use the LPD dual loop powered isolator remove ground loops in multiple 4-20mA current loops where space is at a premium. Incorporating the equivalent of two LPIs in a single 22.5mm housing, the LPD is useful where power is unavailable and there is sufficient spare volt drop in the loop to accommo- date...

Abrir o catálogo na página 4
Next Generation Signal Conditioners - 5

Model C2401 Model C2406 Model C2405 Model C2403 > Application Application Application Application Use the TXB for all your dc signal conditioning needs. This instrument uses easy software configurability without the need for any calibration to set most input and output temperature, voltage and current ranges. Use the TWT for all your two-wire temperature signal conditioning needs. This instrument uses easy software configurability without the need for any calibration to set all thermocouple and resistance bulb types to any input range. Use the TWA module to monitor ac current loads and ac...

Abrir o catálogo na página 5
Next Generation Signal Conditioners - 6

Model C2465 Model C2468 Model C2467 Model C2469 > Application Application Use the TTB to monitor a 0-20mA (4-20mA) or 0-10V (1-5V) signal and output two high or low alarm/trips via form C Relay contact. Use the TTP to monitor any dc instrumentation signal and output two high or low alarm/trips via form C Relay contacts. This instrument uses easy software configurability without the need for any calibration to set most input temperature, voltage and current ranges. Application Application The TTT is a universal input signal transmitter and dual limit alarm relay combining all the features of...

Abrir o catálogo na página 6
Next Generation Signal Conditioners - 7

Application Application Use the PAF to power a system of Omniterm modules when 24Vdc is not available. Use the TFX to perform specialised analogue computation on 4-20mA and 1-5V instrument signals. Benefits Benefits > The same compact 22.5mm housing allows the PAF to mounted on the same DIN rail as other modules without consuming a significant amount of space. Software configuration means setting is done in minutes, and configuration can be stored for effective asset management. Universal 85-264Vac/dc input allows its use with most high voltage sources. All digital design means highest...

Abrir o catálogo na página 7
Next Generation Signal Conditioners - 8

Universal 85-264Vac/dc inputs on all models with CE certification dc/dc converter options available Removable terminal blocks on some models for easy system maintenance Enclosed housings with protected terminals for safe mounting in serviceable areas. 50 000 hour design rating for maximum reliability >

Abrir o catálogo na página 8
Next Generation Signal Conditioners - 9

14 > Under-voltage cutoutShut-down Control AC OK Detect 4 5 > Float voltage control

Abrir o catálogo na página 9
Next Generation Signal Conditioners - 10

Model C2302 Model C2303 Model C2304 Model C2305 > Application Application Application Use the MIR module as a general purpose digital input module from any Modbus network. 20 Way Ribbon Header input is compatible with many Omniflex products. Use the MIT module as a general purpose digital input module to any Modbus network. Screw terminals are provided from open collector transistor outputs Application Use the MOT module as a general purpose digital output module from any Modbus network. Screw terminals are provided from open collector transistor outputs Use the MOR module as a general...

Abrir o catálogo na página 10
Next Generation Signal Conditioners - 11

Connect different manufacturers equipment. High Isolation Analogue and Digital Inputs and Outputs Optional IEC61131 PLC Control Real-time alarm/event management Industrial Networking up to 10km on existing cables Ethernet. HART, Modbus etc. fieldbus support Seamless Inter-networking for wider area solutions Integrated datalogging and multiplexing > Field Proven Җ 30 years of experience in handling critical alarms High Reliability redundant Alarm displays Certified to IEC61508 for safety related alarm functions SCADA, DCS and PLC compatible Serial communications options >

Abrir o catálogo na página 11
Next Generation Signal Conditioners - 12

Available in soft copy as SFOmnitermBR07.pdf Omniflex Pty Ltd 2004 >

Abrir o catálogo na página 12

Todos os catálogos e folhetos técnicos Omniflex

  1. MAXIFLEX Bases

    3 Páginas

  2. Model M1711A HSC

    2 Páginas

  3. Model M1341B 16DO

    2 Páginas

  4. Model M1342A 32DO

    2 Páginas

  5. Model M1372A 8RO

    2 Páginas

  6. Maxilarm

    15 Páginas

  7. Model C2330B-11-0

    6 Páginas

  8. Model C2330B-12-0

    6 Páginas

  9. Model M1403A 16AI

    2 Páginas

  10. Model M1412A 8AO

    2 Páginas

  11. C2404B

    4 Páginas

  12. C118xB series

    4 Páginas

  13. Model M1022B BASE

    3 Páginas

  14. Model M1102A PSU

    2 Páginas

  15. Model M1023B BASE

    3 Páginas

  16. Model M1021B BASE

    3 Páginas

Catálogos arquivados