OM-DAQPRO-5300
1 / 4Páginas

{{requestButtons}}

Excertos do catálogo

OM-DAQPRO-5300 - 1

Portable Handheld Data Logger OM-DAQPRO-5300-UNIV U -Channel Data Logger— 8 Measures Voltage; Current; Pt100 RTD; J, K, T Thermocouples; 2252 Ω or 10 KΩ Thermistors; Frequency/ Pulse Input U larm Output A U 6-Bit Sampling Resolution 1 U ast USB Communications F U apid Sampling—Up to 4000 R Samples/Sec (Single Channel Burst Mode) U arge Data Storage— L 512 KB RAM U raphical Display—Shows G Collected Data as Measured Values, Graphs or Tables U ultiple Logging Sessions— M Stores up to 100 Recording Sessions U owerful Analysis Software P for Windows XP/VISTA/7 The OM-DAQPRO-5300-UNIV is an 8-channel portable data acquisition and logging system with graphic display and built-in analysis functions. The data logger is powered by an internal rechargeable battery and is capable of sampling, processing and displaying measurements without being connected to a computer. Every OM-DAQPRO-5300-UNIV data logger is embedded with a unique serial number and can be loaded with a descriptive comment for safe identification. The data logger is very easy to use because all its functions are broken down into an 8-icon menu. The four buttons on the data logger’s front keypad can be used to browse every menu and execute any of the commands. The OM-DAQPRO-5300-UNIV has eight input channels for measuring voltage, current, temperatureand pulses. User-selectable input types/ranges are 0 to 24 mA, 0 to 50 mV, 0 to 10 V, 2252 Ω or 10 KΩ The OM-DAQPRO-5300-UNIV is a professional, cost-effective, compact thermistors, PT100 RTDs, type J/K/T and stand-alone data logging system thermocouple temperature sensors, that can be used with a wide variety internal temperature, pulse counter, frequency meter and up to 20 userof applications. This 16-bit, highdefined sensors (used for scaling resolution, 8-channel data logger analog voltage or current inputs in has graphic displays and analysis engineering units). functions for measuring voltage, current and temperature in real time. The OM-DAQPRO-5300-UNIV can With its high-resolution and fast record data from up to eight 2-wire or analog-to-digital converter (ADC), the four 3-wire PT100 RTD inputs (two OM-DAQPRO-5300-UNIV meets the input channels are required for each majority of data logging requirements 3-wire PT100 RTD input connected). in most industrial applications. Its Frequency/pulse counter is only unique ability to display measured available for input 1. values and analyze them in real time The data logger provides a on a graphical interface minimizes the need to download collected data simple and straightforward tool for defining up to 20 custom sensors. to a computer for further analysis. Almost any 0 to 10 V and 4 to 20 mA sensor or transducer can be displayed and scaled in meaningful engineering units, e.g., psi or gpm. The sensor definitions are stored in the data logger’s memory and are added to the sensors list. The sensor’s readings are displayed in the user-defined units both on the OM-DAQPRO-5300-UNIV’s LCD screen and the Windows software. The inputs use pluggable screw terminal blocks for easy connection. An internal clock and calendar keep track of the date and time of every sample measured. SM Extended Warranty Program OMEGACARESM extended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARESM covers parts, labor and equivalent loaners.

Abrir o catálogo na página 1
OM-DAQPRO-5300 - 2

The OM-DAQPRO-5300-UNIV data logger includes Windows software on CD ROM, Universal 100 to 240 Vac adaptor, USB cable, NIST calibration certificate, operator’s manual and carrying case. The OM-DAQPRO-5300-UNIV can automatically activate an external alarm device, e.g., energize an audible alarm or turn on a warning light, when an input channel is outside a specified range (Input/ Output 8 serves as either an input or an alarm output). The external alarm device (audible or visual alarm) is connected to the screw terminals of Input/Output 8. The alarm output is an open collector output, which...

Abrir o catálogo na página 2
OM-DAQPRO-5300 - 3

Windows software displays data in graphical or tabular format Windows software high/low alarm setup Internal Temperature Range: -25 to 70°C (-13 to 158°F) Resolution: 0.1°C (1µV) Accuracy: ±0.5°C Pulse Counter (Input 1 Only) Optocoupler Input Range: 0 to 65,000 counts Resolution: 1 count Input Signal: 0 to 5V Input Impedance: 470 Ω Bandwidth: 0 to 25 Hz Frequency Meter (Input 1 Only) Optocoupler Input Range: 20 to 4000 Hz Time Resolution: 6.5 µs Input Signal: 0 to 5V Input Impedance: 470 Ω General A/D Specifications Noise: 30 µV RMS Internal Linearity Error: ±0.08% of FSR Offset Error: 0.1%...

Abrir o catálogo na página 3
OM-DAQPRO-5300 - 4

The OM-DAQPRO-5300-UNIV data logger includes Windows software on CD ROM, universal 100 to 240 Vac adaptor, USB cable, NIST calibration certificate, operator’s manual and carrying case. Analysis Software Operating System: Windows XP/ VISTA/7 Features: • ast data download F • ata displayed in numeric D or graphical form • raphical analysis tools such G as Zoom and Cursors • torage of selected data S on disk files • ard-copy printing of the H collected data • irect data export to Excel D • nline retrieval and display O of data in real time • ncorporates data processing I functions • ata logger...

Abrir o catálogo na página 4

Todos os catálogos e folhetos técnicos OMEGA

  1. WTS Series

    4 Páginas

  2. DPG280

    2 Páginas

  3. OMPBD7 series

    6 Páginas

  4. BEAKER HEATERS

    1 Páginas

  5. Model H

    1 Páginas

  6. MICRO-FLOW METER

    1 Páginas

  7. HHAQ-104

    1 Páginas

  8. DOTX441

    1 Páginas

  9. DOCN600 Series

    2 Páginas

  10. TXDIN1600s

    2 Páginas

  11. M12

    1 Páginas

  12. AHPF Series

    1 Páginas

  13. RFH Series

    2 Páginas

  14. HHM10

    6 Páginas

  15. OMEGA RTD BROCHURE

    32 Páginas

  16. iDRN/iDRX Series

    9 Páginas

  17. RDXL8

    2 Páginas

  18. HHWT-12 Series

    2 Páginas

  19. FD-400 Series

    4 Páginas

  20. M12-TC-SL Series

    1 Páginas

  21. OS-MINIHUB

    4 Páginas

  22. RHCM-40-PL-P

    2 Páginas

  23. OS-MINIUSB-SN21

    2 Páginas

  24. OSAT-151-C-LT-5

    2 Páginas

  25. CSMSTRLE

    3 Páginas

  26. AU-PTV Series

    3 Páginas

  27. ADAM-5000

    7 Páginas

  28. KE Series

    1 Páginas

  29. SRM Series

    3 Páginas

  30. SRL Series

    3 Páginas

  31. PHH-SD1

    2 Páginas

  32. CDH-5020 Series

    1 Páginas

  33. PHH222

    1 Páginas

  34. PHH224

    1 Páginas

  35. PHH720

    1 Páginas

  36. PHH830

    2 Páginas

  37. PHH-126

    1 Páginas

  38. PHH-127

    1 Páginas

  39. PHH-128

    1 Páginas

  40. PHH-37

    1 Páginas

  41. PHH-715

    2 Páginas

  42. PHH103B

    1 Páginas

  43. BB-5

    2 Páginas

  44. BB-2A

    2 Páginas

  45. CA 150

    5 Páginas

  46. CL 110

    2 Páginas

  47. CL 1600

    2 Páginas

  48. CL 1201

    2 Páginas

  49. CL 355A

    2 Páginas

  50. FL 500

    2 Páginas

  51. FL 500WW

    2 Páginas

  52. FL-X

    2 Páginas

  53. FPR 100

    3 Páginas

  54. FL6100SS-7900SS

    2 Páginas

  55. FSW500

    2 Páginas

  56. FSW 420- 430

    2 Páginas

  57. CL 1500 Series

    3 Páginas

  58. CDTX90

    6 Páginas

  59. FSW 6000-7000

    3 Páginas

  60. DRP 8500

    3 Páginas

  61. DP 3300

    2 Páginas

  62. DP119

    1 Páginas

  63. HE-X Series

    3 Páginas

  64. HE359 Series

    3 Páginas

  65. RD4

    2 Páginas

  66. DPi

    3 Páginas

  67. HH311

    2 Páginas

  68. MP1

    1 Páginas

  69. HFS

    2 Páginas

  70. CO

    2 Páginas

  71. WT

    2 Páginas

Catálogos arquivados

  1. Thermowells FTW

    1 Páginas

  2. 6M Series

    2 Páginas