X-DRY - Heatless regenerated modular adsorption dryers
1 / 8Páginas

{{requestButtons}}

Excertos do catálogo

X-DRY - Heatless regenerated modular adsorption dryers - 1

Heatless regenerated modular adsorption dryers

Abrir o catálogo na página 1
X-DRY - Heatless regenerated modular adsorption dryers - 2

X-Dry - Heatless regenerated modular adsorption dryers Four individually controlled valves To provide optimum control over the complete drying process four high quality electromagnetic valves are used. Individual control of each valve results in column switch-over without any pressure peaks. Compact control blocks Pressure indicators Compact and robust design of upper and lower control valve block assures reliable operation. Purge air line is mounted on upper check valve block so that purge air nozzle can be replaced if required. During maintenance complete block can be removed from the...

Abrir o catálogo na página 2
X-DRY - Heatless regenerated modular adsorption dryers - 3

ADSORPTION DRYER Compressed air contains contaminants such as water, oil and particulates which must be removed or reduced to the acceptable level based on specific application requirements. Standard ISO8573-1 specifies air purity/quality classes for these contaminants. Humidity (water vapor content) is expressed in the terms of Pressure Dew Point (PDP) where Dew point is the temperature at which air is 100% saturated with moisture. When the temperature of the air is reduced to or below the dew point, condensation will occur. Reduction of water content down to pressure dew point +3°C is...

Abrir o catálogo na página 3
X-DRY - Heatless regenerated modular adsorption dryers - 4

X-Dry - Heatless regenerated modular adsorption dryers 8 X-DRY adsorption dryers have been designed for continuous separation of water vapour from the compressed air thus reducing the pressure dew point. Compact X-DRY series dryer consists of upper and lower control block, controller with LCD display and minimum two pairs of alternately operated columns filled with desiccant. Adsorption takes place under pressure in the first set of columns while the second set of columns regenerate with a portion of already dried compressed air at the ambient pressure. When the first set of columns is...

Abrir o catálogo na página 4
X-DRY - Heatless regenerated modular adsorption dryers - 5

10 min operating cycle When FIX operating cycle is selected or when the dryer is not equipped with a dew point sensor it will operate in pre-set operating cycles meaning length of adsorption and regeneration will be fixed. Energy losses are directly related with an amount of purge air which is used for regeneration. X-DRY energy losses have been optimized due to the 10 minute operating cycle: - 5min = Adsorption - 4 min = Regeneration - 1 min = Pressure build up Extended operating cycle with 12 switch overs per hour also reflects in less wear and thus more reliable operation. If the dryer...

Abrir o catálogo na página 5
X-DRY - Heatless regenerated modular adsorption dryers - 6

Easy maintenance Due to innovative column design desiccant replacement can be done in an easy and fast way. Complete column can be removed from the dryer and then refilled or completely replaced with a new one. When the column is removed clear access to the check valve and the purge nozzle is available. Valves and membranes are located at the back side of the dryer, on the lower control block and can be accessed and replaced in a quick and easy way. STANDARD YEARLY MAINTENANCE Refers to components such as filter elements and expansion silencers. TWO YEAR SERVICE KIT Refers to valve...

Abrir o catálogo na página 6
X-DRY - Heatless regenerated modular adsorption dryers - 7

Technical data Nominal volume flow Refers to 1bar(a) and 20°C at 7 bar operating pressure, inlet temperature 35°C and pressure dew point at outlet -40°C. (2) Outlet flow refers to typical assumption during regeneration phase for operating at nominal inlet flow conditions. Outlet flow includes average air losses of approximately 17,3 %. (3) Reffers to inlet and outlet filter housing. (1) Operating temperature range Voltage, frequency Power consumption Protection class Filter (inlet)* Filter (outlet) Operating pressure range CORRECTION FACTORS - F1 Operating pressure [bar] Operating pressure...

Abrir o catálogo na página 7
X-DRY - Heatless regenerated modular adsorption dryers - 8

Cesta Dolomitskega odreda 10 SI-1000 Ljubljana, Slovenia www.omega-air.si Eurotec Ring 15 D-47445 Moers, Deutschland www.omega-air.de Anićeva 13A HR-10000 Zagreb, Croatia www.omega-air.hr

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos OMEGA AIR d.o.o. Ljubljana

  1. WFIF SERIES

    2 Páginas

  2. WHFIT SERIES

    2 Páginas

  3. MEGA TOOLS

    12 Páginas

  4. CO2-R-DRY series

    2 Páginas

  5. ACW series

    1 Páginas

  6. ACA series

    1 Páginas

  7. RDHP series

    2 Páginas

  8. RDF

    2 Páginas

  9. RDL series

    2 Páginas

  10. RDP series

    2 Páginas

  11. M-DRY series

    2 Páginas

  12. HP-DRY series

    2 Páginas

  13. R-DRY BVL series

    2 Páginas

  14. R-DRY BP series

    2 Páginas

  15. COM-DRY series

    2 Páginas

  16. X-DRY series

    2 Páginas

  17. A-DRY TAC

    2 Páginas

  18. PV

    2 Páginas

  19. OCI

    1 Páginas

  20. CKL-IHP series

    2 Páginas

  21. SF series

    2 Páginas

  22. WFIW series

    2 Páginas

  23. MSS

    2 Páginas

  24. MDH 400

    1 Páginas

  25. CHI

    1 Páginas

  26. VPG 60

    1 Páginas

  27. TD 400M series

    1 Páginas

  28. AOK 50SS

    1 Páginas

  29. EVD series

    1 Páginas

  30. RC-DRY series

    2 Páginas

  31. HPR-DRY series

    2 Páginas

  32. TAC HP series

    2 Páginas

  33. A-CAT series

    2 Páginas

  34. SFH HP

    2 Páginas

  35. TP PED series

    2 Páginas

  36. TP ASME series

    1 Páginas

  37. TP series

    1 Páginas

  38. BS TOWER

    1 Páginas

  39. PETRO-PACK

    1 Páginas

  40. AWS

    1 Páginas

  41. BS 12-3,5

    1 Páginas

  42. AIRWATT series

    2 Páginas

  43. B-AIR plus series

    2 Páginas

  44. OWT

    2 Páginas

  45. OWE/HWE

    2 Páginas

  46. OWB

    2 Páginas

  47. OBE SERIES

    2 Páginas

  48. ECD-B series

    2 Páginas

  49. MDHI 50

    1 Páginas

  50. BF series

    2 Páginas

  51. HPF series

    2 Páginas

  52. IHP series

    2 Páginas

  53. PF series

    2 Páginas

  54. EPG 60

    1 Páginas

  55. MDM40

    1 Páginas

  56. OCI

    1 Páginas

  57. AV series

    2 Páginas

  58. SPF series

    2 Páginas

  59. CS /CS SS series

    2 Páginas

  60. CKL-CHP series

    2 Páginas

  61. MDM60

    1 Páginas

  62. MDH

    1 Páginas

  63. SORBEO Adsorbents

    2 Páginas

Catálogos arquivados

  1. Biogas plants

    8 Páginas