Excertos do catálogo

Technical Sales (866) 531-6285 orders@ni.com Requirements and Compatibility | Ordering Information | Detailed Specifications For user manuals and dimensional drawings, visit the product page resources tab on ni.com. Completely IEEE 488.2 compatible No external power required Controls up to 14 GPIB instruments Compact size and light weight No GPIB cable required to connect to instruments Plug-and-play configuration Overview The compact NI GPIB-USB-HS transforms any computer with a USB port into a full-function, IEEE 488.2 controller that can control up to 14 programmable GPIB instruments. The small size and light weight of this controller make it ideal for portable applications using a laptop computer or other applications in which the computer has no available internal I/O slots. The GPIB-USB-HS works with Windows 7/Vista/XP/Me/2000/98, Mac OS X, and Linux computers with a USB port. Back to Top Requirements and Compatibility OS Information Linux® Mac OS X Windows 2000/XP Windows 7 Windows 8 Windows 98 Windows ME Windows Vista Application and Technology This controller is easy to install and use because there are no external DIP switches and you do not need to restart your computer for the system to recognize your IEEE 488.2 interface. It is a plug-and-play interface that the OS automatically recognizes and configures as soon as you physically attach it to the USB port on your computer. With the GPIB-USB-HS, you can get up and running quickly, so you can focus on developing your instrument control applications. The GPIB-USB-HS is the first GPIB interface to take advantage of the superior performance of Hi-Speed USB signaling (480 Mbit/s). Plugging it into a Hi-Speed USB port provides industry-leading GPIB performance using both the standard and high-speed IEEE 488.1 handshake. Using a TNT family talker/listener/controller IEEE 488.2 ASIC, the GPIB-USB-HS implements the full range of GPIB controller functions, including those required and recommended by IEEE 488.2. It also implements normal and extended talker and listener, serial and parallel polling, service request, and pass/receive control functions. Drawing power directly from the USB port, the GPIB-USB-HS requires no external power input.
Abrir o catálogo na página 1
GPIB-USB-HS GPIB Instrument Figure 1. Easily connect your GPIB instruments to the USB port of your computer With NI-488.2, you get a robust driver with additional utilities and wizards that help you troubleshoot your applications and decrease your development time (see Figure 2). Furthermore, you maintain compatibility with existing systems. Applications previously written for other National Instruments GPIB controllers can run unmodified with the Connecting the GPIB-USB-HS to Your Instruments This controller does not require a GPIB cable to connect to your instruments. You can attach it...
Abrir o catálogo na página 2
Tight integration with a wide range of hardware Simplified cross-platform communication with network variables Advanced measurement analysis and digital signal processing Measurement Studio .NET tools (included in LabWindows/CVI Full only) Open connectivity with DLLs, ActiveX, and .NET objects The mark LabWindows is used under a license from Microsoft Corporation. Capability to build DLLs, executables, and MSI installers NI Measurement Studio Professional Edition Customizable graphs and charts for WPF, Windows Forms, and ASP.NET Web Forms UI design Analysis libraries for array operations,...
Abrir o catálogo na página 3
Alliance Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 700 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. Back to Top Detailed Specifications AT-GPIB/TNT (PnP), GPIB-USB Interfaces, PCI-8232, NI PCIe-GPIB (Part Number 198405x-0xL), NI PCIe-GPIB+, PCI-GPIB, PCI-GPIB+, PCMCIA-GPIB, PMC-GPIB Environment Operating ambient temperature Operating relative humidity Storage environment...
Abrir o catálogo na página 4
PXI-8232, PXI-GPIB Environment Operating ambient temperature Operating relative humidity Storage ambient temperature Storage relative humidity 0 to 55 °C 10 to 90%, noncondensing –20 to 70 °C 5 to 95%, noncondensing (Tested in accordance with IEC-60068-2-1, IEC-60068-2-2, and IEC-60068-2-56.) Shock and Vibration Functional shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) Random vibration Operating 5 to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the...
Abrir o catálogo na página 5
Operating Environment Ambient temperature range Relative humidity range Power requirements 0 to 55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) 10 to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) External source 9 to 30 VDC, +12 VDC @ 250 mA typical, 500 mA max Storage Environment Ambient temperature range Relative humidity range –40 to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) 5 to 95%, noncondensing (Tested in accordance with IEC-60068-2-56.) Shock and Vibration Operational shock 30 g peak, half-sine, 11 ms pulse (Tested in...
Abrir o catálogo na página 6
Pollution Degree This product is designed to meet the requirements of the following standards of safety for information technology equipment: /j\ Caution Overloading the circuits may damage supply wiring. Do not exceed the ratings on the equipment nameplate when connecting equipment to the supply circuit. j^J, Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:...
Abrir o catálogo na página 7Todos os catálogos e folhetos técnicos NATIONAL INSTRUMENTS
-
Multifunction Input and Output Devices
24 Páginas
-
NI 9381
10 Páginas
-
NI 9402
9 Páginas
-
BNC-2121
3 Páginas
-
Counter/Timer
10 Páginas
-
NI PXIe-6612
12 Páginas
-
ds-392
7 Páginas
-
ETC_196
9 Páginas
-
ds-293
13 Páginas
-
ds-353
14 Páginas
-
ds-361
5 Páginas
-
NI WSN-3202
13 Páginas
-
cat_ni31xx
5 Páginas
-
PXI-4072 FlexDMM
5 Páginas
-
2005_6175_161_101
4 Páginas
-
Digital I/O,
9 Páginas
-
NI PCI-6624, NI PXI-6624
8 Páginas
-
NI PCIe-6321
15 Páginas
-
NI USB-6509
8 Páginas
-
NI_PCI-6713.
5 Páginas
-
NI_PCIe-6363
5 Páginas
-
NI_GPIB-USB-HS
4 Páginas
-
Counter_Timer_Devices
1 Páginas
-
NI_EVS-1464
9 Páginas
-
daqsc208-209_212-2
2 Páginas
-
ds-153
18 Páginas
-
ds-37
14 Páginas
-
NI4065
6 Páginas
-
4daqsc253
17 Páginas
-
NI_1778_Smart_Camera
5 Páginas
-
NI_PCI-5122
5 Páginas
-
NI_EVS-1464_(Windows)
9 Páginas
-
4daqsc253-265_194-196
17 Páginas
-
NI-Datasheet-ds-293
13 Páginas
-
NI_PXIe-8100_RT
3 Páginas
-
NI_FPT-1015
3 Páginas
-
NI_PXI-2501
5 Páginas
-
2005_6174_161_101_d
5 Páginas
-
cat_FET
3 Páginas
-
cat_evs1464RT
9 Páginas
-
4daqsc253-265
17 Páginas
-
043918301101dlr
7 Páginas
-
4daqsc208-209
2 Páginas
-
usb-datasheet
14 Páginas
-
NI_9478
4 Páginas
-
Documents\NI_9476_Measurement_System
4 Páginas
-
NI_9472_Measurement_System
4 Páginas
-
NI_9402_Measurement_System
4 Páginas
-
NI_9263_Measurement_System
4 Páginas
-
NI_9235_9236_Measurement_System
4 Páginas
-
NI_9203_Measurement_System
4 Páginas
-
NI_9208_Measurement_System
4 Páginas
-
NI_9239_Measurement_
4 Páginas
-
_Measurement_System
4 Páginas
-
Measurement_System
4 Páginas
-
_Measurement_
4 Páginas
-
NI_CompactDAQ_Multifunction_System
4 Páginas
-
NI_cDAQ-9171
3 Páginas
-
NI_cDAQ-9174
5 Páginas
-
NI_cDAQ-9178
5 Páginas
-
NI_cDAQ-9181
4 Páginas
-
NI_cDAQ-9188
5 Páginas
-
Wireless_Chassis
1 Páginas
-
NI_cDAQ-9139
4 Páginas
Catálogos arquivados
-
P70360 1-Axis, 525 W Stepper Drive
2 Páginas
-
CompactRIO Real-Time Controllers
1 Páginas
-
PXI Embedded Controllers
1 Páginas
-
LabVIEW Real-Time Module
3 Páginas
-
NI CompactDAQ Chassis
1 Páginas