ds-392
1 / 7Páginas

Excertos do catálogo

ds-392 - 1

Technical Sales (866) 531-6285 orders@ni.com Detailed Specifications | Pinouts/Front Panel Connections For user manuals and dimensional drawings, visit the product page resources tab on ni.com. NI SCXI-1100 32-Channel, ±10 V Analog Input Module 166 kS/s maximum sampling rate at full bandwidth with gain up to 100 3 S/s maximum sampling rate with 4 Hz filter 6.6 kS/s maximum sampling rate with 10 kHz filter NI-DAQmx measurement services software to simplify configuration and measurements Overview The NI SCXI-1100 analog input module is an economical solution for millivolt, volt, and current inputs. All 32 channels are multiplexed into a single software-programmable gain instrumentation amplifier (PGIA) and jumper-selectable lowpass filter. Because each module multiplexes the 32 channels into a single channel of the DAQ device, you can add modules to increase channel count. For thermocouple measurements, the NI SCXI-1102 offers gain and filter settings on a per channel basis and provides better performance and higher sampling rates. An SCXI chassis is required to house the SCXI modules. The NI SCXI-1000 chassis can hold up to four modules while the NI SCXI-1001 can hold up to 12. You can choose NI X Series, M Series, E Series, or S Series DAQ modules to control the chassis. Back to Top Support and Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system-specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni.com/advisor to find a system assurance program to meet your needs. Calibration NI measurement hardware is calibrated to ensure measurement accuracy and verify that the device meets its published specifications. To ensure the ongoing accuracy of your measurement hardware, NI offers basic or detailed recalibration service that provides ongoing ISO 9001 audit compliance and confidence in your measurements. To learn more about NI calibration services or to locate a qualified service center near you, contact your local sales office or visit ni.com/calibration. Technical Support Get answers to your technical questions using the following National Instruments resources. Support - Visit ni.com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales offices around the world and speak the local language. Discussion Forums - Visit forums.ni.com for a diverse set of discussion boards on topics you care about. Online Community - Visit community.ni.com to find, contribute, or collaborate on customer-contributed technical content with users like you.

Abrir o catálogo na página 1
ds-392 - 2

While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni.com/repair. Training and Certifications The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable...

Abrir o catálogo na página 2
ds-392 - 3

Amplifier Characteristics Input impedance >1 GΩ Input bias current Input offset current CMRR Characteristics Output range Output impedance Dynamic Characteristics Bandwidth Minimum scan interval (per channel, any gain) ±0.012% accuracy System noise (RTI) Characteristics 50 μVrms 50 μVrms 70 μVrms Step response (either gain) Characteristics 1102 Recommended warm-up time Offset temperature coefficient Gain temperature coefficient ±15 V supply (regulated from ±24 V

Abrir o catálogo na página 3
ds-392 - 4

Maximum Working Voltage Maximum working voltage refers to the signal voltage plus the common-mode voltage. Each input should remain within ±10 V of CH GND Signal + common mode Environmental Operating temperature Storage temperature Maximum altitude Pollution Degree (indoor use only) Safety Standards This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online...

Abrir o catálogo na página 4
ds-392 - 5

Bl^ NoNonol Instruments VlM'^'li-T^f^'^'mmmil-mmmm^ (RoHS). ST Notional Instruments 'I'M ROHS frWJ-flTjfit. ni.com/environmont/rohQ_ohinii, (For Information about China RoHS compliance, go to nl. cam/eiivironment/roha_eliina,)

Abrir o catálogo na página 5
ds-392 - 6

Pinouts/Front Panel Connections Rear Signal Pin Assignments

Abrir o catálogo na página 6
ds-392 - 7

SCXI-ILCIWC Front Signal Pin Assignments ©2012 National Instruments. All rights reserved. CompactRIO, FieldPoint, National Instruments, Nl, ni.com, NI-DAQ, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint-venture relationship with National Instruments. My Profile | RSS | Privacy | Legal | Contact Nl © 2014 National Instruments Corporation. All rights...

Abrir o catálogo na página 7

Todos os catálogos e folhetos técnicos NATIONAL INSTRUMENTS

  1. NI 9381

    10 Páginas

  2. NI 9402

    9 Páginas

  3. BNC-2121

    3 Páginas

  4. Counter/Timer

    10 Páginas

  5. NI PXIe-6612

    12 Páginas

  6. ETC_196

    9 Páginas

  7. ds-293

    13 Páginas

  8. ds-353

    14 Páginas

  9. ds-361

    5 Páginas

  10. NI WSN-3202

    13 Páginas

  11. cat_ni31xx

    5 Páginas

  12. PXI-4072 FlexDMM

    5 Páginas

  13. GPIB-USB-HS

    7 Páginas

  14. 2005_6175_161_101

    4 Páginas

  15. Digital I/O,

    9 Páginas

  16. NI PCIe-6321

    15 Páginas

  17. NI USB-6509

    8 Páginas

  18. NI_PCI-6713.

    5 Páginas

  19. NI_PCIe-6363

    5 Páginas

  20. NI_GPIB-USB-HS

    4 Páginas

  21. NI_EVS-1464

    9 Páginas

  22. ds-153

    18 Páginas

  23. ds-37

    14 Páginas

  24. NI4065

    6 Páginas

  25. 4daqsc253

    17 Páginas

  26. NI_PCI-5122

    5 Páginas

  27. NI_PXIe-8100_RT

    3 Páginas

  28. NI_FPT-1015

    3 Páginas

  29. NI_PXI-2501

    5 Páginas

  30. cat_FET

    3 Páginas

  31. cat_evs1464RT

    9 Páginas

  32. 4daqsc253-265

    17 Páginas

  33. 043918301101dlr

    7 Páginas

  34. 4daqsc208-209

    2 Páginas

  35. usb-datasheet

    14 Páginas

  36. NI_9478

    4 Páginas

  37. _Measurement_

    4 Páginas

  38. NI_cDAQ-9171

    3 Páginas

  39. NI_cDAQ-9174

    5 Páginas

  40. NI_cDAQ-9178

    5 Páginas

  41. NI_cDAQ-9181

    4 Páginas

  42. NI_cDAQ-9188

    5 Páginas

  43. Wireless_Chassis

    1 Páginas

  44. NI_cDAQ-9139

    4 Páginas

Catálogos arquivados