ds-293
1 / 13Páginas

Excertos do catálogo

ds-293 - 1

Technical Sales (866) 531-6285 orders@ni.com Ordering Information | Detailed Specifications | Pinouts/Front Panel Connections For user manuals and dimensional drawings, visit the product page resources tab on ni.com. Wireless Sensor Network Analog Input Nodes NI WSN-3202, NI WSN-3212, NI WSN-3226 Support for hundreds of nodes to help you create a reliable network to monitor your assets or environment Four analog input channels per measurement node NI-WSN software that provides easy network configuration, drag-and-drop LabVIEW programming, and support for logging, alarming, and Web-based data visualization Bidirectional digital channels; configurable for input, sinking output, or sourcing output (2 to 4 DIO channels per node) Industrial ratings: -40 to 70 °C operating temperature and 50 g shock, 5 g vibration Low-power operation, up to 3-year battery life 2.4 GHz, IEEE 802.15.4 radio that provides up to 300 m outdoor range Overview The National Instruments wireless sensor network (WSN) platform delivers low-power measurement nodes that offer industrial certifications, reliable networking, and optional weatherproof outdoor enclosures for long-term, remote monitoring applications. The measurement nodes have direct sensor connectivity and a 2.4 GHz radio to wirelessly transmit data to a WSN gateway. Each measurement node offers four analog input channels and two to four digital I/O channels that you can configure for input, sinking output, or sourcing output. With graphical NI LabVIEW software, you can easily configure your network, collect measurement data, trigger alarms through SMS or e-mail, and even view monitoring data within a Web browser. Back to Top Comparison Tables Signal Type(s) Analog Minimum Resolution Input DIO Input Sample Interval (bits) Range(s) Channels Channels (seconds) Maximum DIO Sourcing (aggregate) Additional Features 12 V, 20 mA sensor power output Support for J, K, R, S, T, N, B, E thermocouple types 12 V, 50 mA sensor power output, 50/60 Hz rejection, battery backup support Back to Top Application and Technology Power You can power the NI WSN measurement nodes with four 1.5 V AA alkaline battery cells, delivering three-year battery-powered operation at a one-minute sample interval. The NI WSN-3226 also supports 1.5 V AA lithium cells. Each node features an external power port, so you can provide line power or use other forms of power such as solar or vibration

Abrir o catálogo na página 1
ds-293 - 2

energy harvesting. The WSN-3226 supports battery backup, meaning you can connect both external and battery power; the node defaults to external power and automatically switches to battery power in the event the external power drops below a voltage threshold. The external power input should be used to power Nl WSN nodes operating in router mode, which is a feature that you can enable in software to set up a self-healing mesh network of nodes. Router nodes increase density, distance, and redundancy in your wireless network. Each node offers bidirectional digital I/O channels for input,...

Abrir o catálogo na página 2
ds-293 - 3

43 Host ConUoMeT VI.vi Black Diagram on WSM Project.Ivproj/My Computer [-J[nj^ File £,dit vfew Reject Qper-ate rools Window Help <> 1^1 ' ■ |"fi"| "I \%] l^tfi ,j" | 13P Application Fan; 7] | °~][ ThermcQcc-jple Channel 11 Current Temperate |Node Prpperbesj Create histogram Figure 2. Extracting Nl WSN Measurement Data Using LabVIEW and I/O Variables LabVIEW delivers a common development environment for all of your monitoring and control applications as well as rapid programming, easy network configuration, and open connectivity to a variety of third-party instruments and systems. And with a...

Abrir o catálogo na página 3
ds-293 - 4

Signal Strength Terminal Connector Figure 4. Measurement Node External Features Figure 5. Outdoor Enclosure With Nl WSN Measurement Node (not included) Nl WSN accessories include options for gateway and measurement node mounting as well as weatherproof enclosures for outdoor use of the measurement nodes and gateways. Available mounting accessories offer options to panel mount and DIN-rail mount WSN measurement nodes and gateways. The Nl WSN-3281 magnetic panel mount kit provides easy setup and takedown on virtually any metal surface. For high shock and vibration applications, Nl recommends...

Abrir o catálogo na página 4
ds-293 - 5

Support and Services System Assurance Programs NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create...

Abrir o catálogo na página 5
ds-293 - 6

No missing codes guaranteed Refer to the Absolute Accuracies Formulas section Minimum sample interval Input coupling Nominal input ranges Minimum over range Input impedance (at DC) Powered off/overload Input bias current Crosstalk (at 1 KHz) Adjacent channels Non-adjacent channels Analog bandwidth Overvoltage protection AI Absolute Accuracy Tables and Formulas The values in the following tables are based on calibrated scaling coefficients, which are stored in the onboard EEPROM. Accuracy Summary * Maximum Absolute Accuracy (mV) –40 to 70 °C Typical Absolute Accuracy (mV)* 25 ° ±5 °C Random...

Abrir o catálogo na página 6
ds-293 - 7

Sensor Power Voltage Typical (10 mA) Minimum Maximum Output Current Delay from sensor power active to measurement Digital I/O Number of channels 4 bi-directional, individually settable Modes (configurable per channel) Drive High Only, Drive Low Only, Drive High and Low, and Tristate Power-on output state High Impedance, Tristate DIO power supply voltage range (VDIO_PWR) Digital Output Total DIO current (all channels) Output current (one channel) Output voltage Sourcing Protection Voltage Reversed voltage Short circuit Trip current Trip time Switching time Sinking, 10 KΩ pull-up Digital...

Abrir o catálogo na página 7

Todos os catálogos e folhetos técnicos NATIONAL INSTRUMENTS

  1. NI 9381

    10 Páginas

  2. NI 9402

    9 Páginas

  3. BNC-2121

    3 Páginas

  4. Counter/Timer

    10 Páginas

  5. NI PXIe-6612

    12 Páginas

  6. ds-392

    7 Páginas

  7. ETC_196

    9 Páginas

  8. ds-353

    14 Páginas

  9. ds-361

    5 Páginas

  10. NI WSN-3202

    13 Páginas

  11. cat_ni31xx

    5 Páginas

  12. PXI-4072 FlexDMM

    5 Páginas

  13. GPIB-USB-HS

    7 Páginas

  14. 2005_6175_161_101

    4 Páginas

  15. Digital I/O,

    9 Páginas

  16. NI PCIe-6321

    15 Páginas

  17. NI USB-6509

    8 Páginas

  18. NI_PCI-6713.

    5 Páginas

  19. NI_PCIe-6363

    5 Páginas

  20. NI_GPIB-USB-HS

    4 Páginas

  21. NI_EVS-1464

    9 Páginas

  22. ds-153

    18 Páginas

  23. ds-37

    14 Páginas

  24. NI4065

    6 Páginas

  25. 4daqsc253

    17 Páginas

  26. NI_PCI-5122

    5 Páginas

  27. NI_PXIe-8100_RT

    3 Páginas

  28. NI_FPT-1015

    3 Páginas

  29. NI_PXI-2501

    5 Páginas

  30. cat_FET

    3 Páginas

  31. cat_evs1464RT

    9 Páginas

  32. 4daqsc253-265

    17 Páginas

  33. 043918301101dlr

    7 Páginas

  34. 4daqsc208-209

    2 Páginas

  35. usb-datasheet

    14 Páginas

  36. NI_9478

    4 Páginas

  37. _Measurement_

    4 Páginas

  38. NI_cDAQ-9171

    3 Páginas

  39. NI_cDAQ-9174

    5 Páginas

  40. NI_cDAQ-9178

    5 Páginas

  41. NI_cDAQ-9181

    4 Páginas

  42. NI_cDAQ-9188

    5 Páginas

  43. Wireless_Chassis

    1 Páginas

  44. NI_cDAQ-9139

    4 Páginas

Catálogos arquivados