L1-150M Multi-standard Single-path LISN
1 / 2Páginas

Excertos do catálogo

L1-150M Multi-standard Single-path LISN - 1

Multi-standard Single-path LISN Provided Features • • • • Powering the EUT EUT termination to a standardized impedance respect to the reference ground Coupling the measuring receiver to the disturbance generated by the EUT Decoupling the measuring receiver from unwanted RF signals from the power line Main Features • • • • • • • • • L1-150M: 100 kHz to 200 MHz frequency range L1-150M1: 10 kHz to 400 MHz frequency range Multi standard design 150 A max output current Suitable also for DC lines Large baseplate for optimal grounding Robust, compact construction Screw terminals for safe wiring Meets the requirements of several standards including CISPR 16-1-2, CISPR 25, ISO 11452-2/4/5, ISO 7637-2, MIL-STD-461F, DO-160, ED-14G The AMN - Artificial Mains Network, also known as LISN - Line Impedance Stabilization Network is the ancillary device intended for repeatable and accurate measurement of the disturbance voltage that an EUT (Equipment Under Test) may inject into the power line or mains. This is obtained by providing well known impedance value and phase response across the frequency range of the test. L1-150M and L1-150M1 are a single-path LISN (Line Impedance Stabilization Network) designed to be easily used for conducted disturbances measurements according to different standards for Automotive and ISM (Industrial, Scientific, Medical) applications. Selecting the standard is as fast as the turn of a rotary switch located on the rear panel. PMM Artificial Mains Networks provide robust and stable mechanical construction, high quality electric components, easy and perfect grounding, solid input and output power connections. They can be used in conjunction with any EMI receiver or spectrum analyzer and offer features required for safe, repeatable and accurate measurements.

Abrir o catálogo na página 1
L1-150M Multi-standard Single-path LISN - 2

Multi-standard Single-path LISN L1-150M 100 kHz to 200 MHz 10 kHz to 400 MHz 100 A 150 A 600 VDC 300 VAC DC to 440 Hz (5 μH+0/1 Ω)//50 Ω N female, 50 Ω Screw terminal M10 Screw terminal M10 2x Screw terminal M10 -10 to +45 °C -25 to +70 °C 230 x 105 x 410 mm 5 kg Ordering Information: L1-150M - L1-150M1 Artificial Network Includes: Operating Manual, RF Cable, N-BNC adapter, Calibration Certificate Electrical safety and presence of ground protection relays do require the installation of properly rated insulating transformer(s) between mains power line and AMN line inputs. High mains noise...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Narda Safety Test Solutions GmbH

  1. Datasheet_EF6092

    2 Páginas

  2. NIM-511/513

    4 Páginas

  3. NBM-580

    4 Páginas

  4. Area monitoring

    16 Páginas

  5. HUMAN SAFETY

    8 Páginas

  6. EHP-200A

    7 Páginas

  7. THM 1176

    6 Páginas

  8. SRM-3006

    24 Páginas

  9. EFC-400LF

    6 Páginas

  10. EHP-50D

    12 Páginas

  11. ELT-400

    8 Páginas

  12. EFA-300

    10 Páginas

  13. RadMan XT

    5 Páginas

Catálogos arquivados

  1. SMARTS II

    4 Páginas

  2. Nardalert XT

    6 Páginas

  3. EHP-200

    7 Páginas

  4. EHP-50

    9 Páginas

  5. THM1176-PDA

    6 Páginas