Consensus with ISO 13849-1
1 / 6Páginas

{{requestButtons}}

Excertos do catálogo

Consensus with ISO 13849-1 - 1

MAYSER* Consensus with ISO 13849-1 F0 en Mayser GmbH & Co. KG Orlinger StraBe 1-3 89073 Ulm GERMANY Phone: +49 731 2061-0 Fax: +49 731 2061-222 E-mail: info.ulm@mayser.com Internet: www.mayser.com

Abrir o catálogo na página 1
Consensus with ISO 13849-1 - 2

Safety according to ISO 13849-1:2015 Performance Level Category MTTFd level MTTFD DCavg level DC avg B10D [* 106] Reaction time 11 assumed parameters : dop = 365 d/a, hop = 24 h/d, tcycle = 600 s (nop = 52560/a) 2) Suitable for installation of Category 3 systems up to PL d. 3) MTTFd level and value are dependent on the particular application (see page 4) 4) dependent on profile 2/6 Consensus with ISO 13849-1

Abrir o catálogo na página 2
Consensus with ISO 13849-1 - 3

Miniature safety edges EKS assumed parameters : dop = 365 d/a, hop = 24 h/d, tcycle = 600 s (nop = 52560/a) Suitable for installation of Category 3 systems up to PL d. 3) MTTFD level and value are dependent on the particular application (see page 4). 4)

Abrir o catálogo na página 3
Consensus with ISO 13849-1 - 4

Determining the PLr For each selected safety function it is first necessary to determine the required performance level (PLr) and to compare it with the performance level (PL) achieved by the Mayser sensor. The PLr of the safety function must correspond at least to the PL. Example 1: Safety mat in front of processing centre with 30-second cycle in 3-shift operation, 250 days per year. nop= 120 actuations/h x 24 h/day x 250 days = 720,000 actuations per year MTTFd = B10D/ (0.1 x nop) = 6,000,000 / (0.1 x 720,000) = 83.3 years => MTTFd high Example 2: NC safety edge on sliding gate with 2...

Abrir o catálogo na página 4
Consensus with ISO 13849-1 - 5

The same example with exclusion of error according to ISO 13849-2 Table D.8: Non-closing of contacts in the case of pressure-sensitive equipment according to ISO 13856. In this case the MTTFD value of the sensor is no longer taken into account for the overall system. Example 4: As in example 3; Safety mat SM connected to SG-EFS 1X4 ZK2/1. MTTFd SG = 313 years -1- -1- MTTFd 313 years MTTFd = 313 years => MTTFD high In this case, the maximum performance level of the overall system can reach PL d. DCavg table Designation DCavg

Abrir o catálogo na página 5
Consensus with ISO 13849-1 - 6

Determining the PL If the categories, DCavgand MTTFDare known, the performance level (PL) can be determined based on the table. The table shows a simplified procedure for assessment and is used in the first step for estimating the PL. => DC low avg => MTTFd high => PL d Example 5: SG-EFS 104/2W Category 3 DCavg = 60 % MTTFd = 257 years Result:

Abrir o catálogo na página 6

Todos os catálogos e folhetos técnicos Mayser

  1. Public transport

    9 Páginas

  2. Industry Brochure

    16 Páginas

  3. Product catalog

    268 Páginas

  4. Safety shoe

    4 Páginas

Catálogos arquivados

  1. Aviation brochure

    9 Páginas

  2. Control Units

    3 Páginas

  3. Safety Mat SM11

    13 Páginas

  4. Safety Mats SM

    20 Páginas

  5. Safety Bumper

    10 Páginas

  6. Safety Edges

    34 Páginas

  7. Safety Bumpers

    10 Páginas