Excertos do catálogo

PROCESS101 CURRENT DATA LOGGER Features Programmable engineering units Real-time operation Programmable start time CE compliant Reusable Compact User-friendly Low cost Applications 4 to 20 mA recording pH recording Low level signal monitoring Photovoltaic studies Battery studies Factory process control Biological sensor monitoring Medical and Pharmaceutical Environmental studies Research and development The Process101 is engineered for accuracy and flexibility unequaled in the 4-20mA loop sensor and control industry. It can be inserted almost anywhere because it adds very little resistance to the loop (10 typical). Since it operates with an internal battery (user replaceable), ground loop errors can be avoided. The Process101 can measure currents that are slightly negative, allowing for other uses. With 16 bits of resolution, it is ideal for accurately measuring battery currents, solar cell currents and other current sources. The device can measure and record up to 32,767 readings in non-volatile memory, retaining valuable data even if the battery should become discharged. Additionally, customized engineering units can be defined to map the measured data to almost any unit imaginable. For example, a 4-20mA flow meter might exert 4mA current for 0 liters of water and 20mA current for 5 liters of water. Using the Engineering Units in the device, the logger can be set up to natively display the data in liters rather than milliamps — a useful feature for presentations! MadgeTech Data Recorder Software displays current data in an easy to use graph. The Windows®-based software package allows the user to effortlessly collect, display and analyze data. A variety of powerful tools allow you to examine, export, and print professional looking data with just a click of the mouse. Click MadgeTech Software for more information or to download the software. 879 Maple Street · Contoocook, NH 03229 PO Box 50 · Warner, NH 03278 · Phone: (603) 456-2011 · Fax: (603) 456-2012
Abrir o catálogo na página 1
Input Connection: Removable screw terminal Analog Conversion Time: 1 33ms nominal Temperature Coefficient: < 100 ppm/°C; < 50 ppm/°C typical Overload Protection: ±1 25mA for 1 0 seconds Specified Accuracy Range: Nominal range @ 25°C Engineering Units: User may define units up to 10 characters in length. This value is stored within the Scale Factor: User may program any desired scaling stored within the device. Start Modes: Software programmable immediate start or delay start up to six months Reading Rate: Real Time Recording: Calibration Date: Battery Type: Battery Life: Data Format: Time...
Abrir o catálogo na página 2Todos os catálogos e folhetos técnicos MadgeTech
-
Volt101A
2 Páginas
-
VoltX Series
2 Páginas
-
VTMS
2 Páginas
-
WIND101A
2 Páginas
-
RTDTemp101A
2 Páginas
-
RHTemp101A
2 Páginas
-
RHTemp1000IS
2 Páginas
-
RFPRHTemp2000A
2 Páginas
-
RFOT
2 Páginas
-
Rain101A
2 Páginas
-
QUADTCTEMP2000V2
2 Páginas
-
LEVEL1000
2 Páginas
-
LCS140
2 Páginas
-
IRTC101A
2 Páginas
-
HiTemp140X2-FP
2 Páginas
-
HiTemp140X2-TD
2 Páginas
-
ETR101A
2 Páginas
-
Element HT
2 Páginas
-
ELEMENT CO2
2 Páginas
-
HiTemp140-PT
2 Páginas
-
Data Logging Solutions
27 Páginas
-
MadgeTech Catalog
139 Páginas
-
SVR101 Spectral Vibration Recorder
2 Páginas
-
current data-logger RFProcess101A
2 Páginas
-
current data-logger OctProcess
2 Páginas
-
Event110 Event recorder
2 Páginas
-
voltage data-logger OctVolt
2 Páginas
-
pressure data-logger PRTemp1000D
2 Páginas
-
pressure data-logger PR2000
2 Páginas
-
temperature data recorder Temp100
2 Páginas
-
temperature data logger OT1000
2 Páginas
-
thermocouple data logger OctTemp
2 Páginas
-
temperature recorder MicroTemp
2 Páginas
-
temperature data-logger RTDTemp2000
2 Páginas
-
temperature data-logger SGTemp1000
2 Páginas
-
Infrared Thermocouple Data Logger
2 Páginas
-
temperature data-logger Cryo-Temp
2 Páginas
-
temperature data-logger HiTemp150
2 Páginas