Excertos do catálogo

SERIAL INTERFACE
Abrir o catálogo na página 1
SM32 SHOWN WITH 92 SERIES REMOTE STACK INPUT/OUTPUT MODULES TETHERED INPUT/OUTPUT MODULES B E N E F I T S 1. Ability to interface with the MAConnect™ system 2. Ease of installation 3. Reduction in wiring costs 4. Washdown capability INPUTS 4 on Serial Module Up to 16 on Tethered Module Up to 16 (4 Per Add-A-Unit Module) 16 Solenoids Possible Up to 16 Outputs on Tethered Module 4 Outputs On Add-A-Unit Module DeviceNet Remote I/O InterBus Profibus * AS-I * AS-I has up to 8 input/8 output capabilit
Abrir o catálogo na página 2
NUMBER: 16 CHANNETS / SOTENOIDS ON MANIFOTD VOTTAGE / CURRENT: 24 VDC / .225A PER CHANNET (5.4 WATTS MAX) DEVICENET, ATTEN-BRADTEY REMOTE I/O, PROFIBUS DP, INTERBUS, AS-I SUPPTY VOTTAGE: OPERATING WITH SINGTE SUPPTY: 24 VDC ±10% OPERATING SEPARATE SUPPTY FOR VATVES: 24 VDC ±10% WEEDING VERSION: DESIGNED TO MEET NEMA4 WITH VATVES BUITT TO WASHDOWN MOD ABITITY TO INTERFACE TO WATER SAVER VATVES ABITITY TO CONTROT A MAC PROPORTIONAT PRESSURE CONTROTTER (PPC)
Abrir o catálogo na página 3
SM128 SHOWN WITH 92 SERIES 1. Ability to interface with the MAConnect™ system 2. Multiple SMI28 receiver manifolds may be added in the field (up to 4 units) 4. Reduction in wiring costs INPUTS PER SMI28 RECEIVER OUTPUTS PER SMI28 RECEIVER PROTOCOLS Up to 16 on Tethered Module 16 Solenoids Possible DeviceNet Up to 16(4 Per Add-A-Unit Module) Up to 16 Outputs on Tethered Module Ethernet IP 4 Outputs On Add-A-Unit Module Profibus DP
Abrir o catálogo na página 4
DEVICENET, ETHERNET IP, PROFIBUS DP CURRENT CONSUMPTION: SUPPLY VOLTAGE: OPERATING TEMPERATURE: PROFIBUS DESIGNED NUMBER: VOLTAGE / CURRENT: 16 CHANNELS / SOLENOIDS ON MANIFOLD 24 VDC / .225A PER CHANNEL (5.4 WATTS MAX) 2 BYTES CONSUMED PER RECEIVER NUMBER: TYPE: CURRENT CONSUMPTION: OUTPUTS - 4 A MAX. ELECTRONICS AND INPUTS 400 SUPPLY VOLTAGE: OPERATING OPERATING INPUTS ACTIVE) SINGLE SUPPLY: 24 VDC ±10% SUPPLY FOR VALVES: 24 VDC ±10% OPERATING TEMPERATURE: NEMA4 WITH VALVES BUILT TO WASH
Abrir o catálogo na página 5
SM256 SHOWN WITH 92 SERIES B E N E F I T S 1. Ability to interface with the MAConnect™ system 2. Multiple SM256 receiver manifolds may be added in the field (up to 8 units) 3. Ease of installation 4. Reduction in wiring costs 5. Washdown capability INPUTS PER SM256 RECEIVER Up to 16 on Tethered Module Up to 16 (4 Per Add-A-Unit Module) OUTPUTS PER SM256 RECEIVER 16 Solenoids Possible Up to 16 Outputs on Tethered Module 4 Outputs On Add-A-Unit Module PROTOCOLS DeviceNet Ethernet IP Profibus
Abrir o catálogo na página 6
DEVICENET, ETHERNET IP, PROFIBUS DP CURRENT CONSUMPTION: SUPPLY VOLTAGE: OPERATING TEMPERATURE: PROFIBUS DESIGNED NUMBER: VOLTAGE / CURRENT: 16 CHANNELS / SOLENOIDS ON MANIFOLD 24 VDC / .225A PER CHANNEL (5.4 WATTS MAX) 2 BYTES CONSUMED PER RECEIVER NUMBER: TYPE: CURRENT CONSUMPTION: OUTPUTS - 4 A MAX. ELECTRONICS AND INPUTS 400 SUPPLY VOLTAGE: OPERATING OPERATING INPUTS ACTIVE) SINGLE SUPPLY: 24 VDC ±10% SUPPLY FOR VALVES: 24 VDC ±10% OPERATING TEMPERATURE: NEMA4 WITH VALVES BUILT TO WASH
Abrir o catálogo na página 7
SM16 SHOWN WITH 44 SERIES 1. Ability to interface with the MAConnect™ system 3. Reduction in wiring costs 4. Washdown capability for approved valve series. 5. Small envelope size INPUTS OUTPUTS PROTOCOLS
Abrir o catálogo na página 8
OUTPUTS: NUMBER: 16 CHANNETS / SOTENOIDS ON MANIFOTD VOTTAGE / CURRENT: 24 VDC / .225A PER CHANNET (5.4 WATTS MAX) INPUTS: NUMBER: NONE PROTOCOTS: DEVICENET SUPPTY VOTTAGE: OPERATING WITH SINGTE SUPPTY: 24 VDC ±10% OPERATING WITH SEPARATE POWER SUPPTY FOR VATVES: 24VDC ±10% ENCTOSURE: DESIGNED TO MEET NEMA 4 WITH VATVES BUITT TO WASHDOWN MOD
Abrir o catálogo na página 9
1. Ability to easily add input/output modules in the field 3. Reduction in wiring costs INPUTS OUTPUTS PROTOCOLS Up to 32 Input Capacity 24 Solenoids on Valve Stack DeviceNet (8 Inputs per Module) 8 Additional Outputs Possible Remote I/O (4 Outputs per Module) InterBus
Abrir o catálogo na página 10
24 CHANNELS / SOLENOIDS ON MANIFOLD 4 CHANNELS / SOLENOIDS PER OUTPUT MODULE (2 MODULES 32 CHANNELS / SOLENOIDS 24 VDC / .25A PER CHANNEL (6 WATTS MAX) TOTAL OUTPUTS: VOLTAGE / CURRENT: INPUTS: TOTAL INPUTS: MODULES: NOTE: INPUT MODULE (4 MODULES MAX.) 32 CHANNELS POSITIVE COMMON NEGATIVE COMMON (BASED ON DIRECTION OF CURRENT) MODULES TO BE INSTALLED AS INDICATED ON BASE UNIT ALLEN-BRADLEY REMOTE I/O, DEVICENET, PROFIBUS DP, INTERBUS CURRENT CONSUMPTION: INTERNAL SERIAL INTERFACE - 300 OUTPUTS - 8A MAX. INPUTS - 3A MAX. SUPPLY VOLTAGE: OPERATING WITH SINGLE SUPPLY: 24 VDC ±10% OPERATING...
Abrir o catálogo na página 11
SLIM SHOWN WITH 92 SERIES 2. Reduction in wiring costs INPUTS OUTPUTS PROTOCOLS None Up to 32 Solenoids DeviceNet
Abrir o catálogo na página 12
OUTPUTS: INPUTS: NUMBER: VOLTAGE / CURRENT: NUMBER: 32 CHANNELS / SOLENOIDS ON MANIFOLD 24 VDC / .25A PER CHANNEL (6 WATTS MAX) ALLEN-BRADLEY REMOTE I/O, DEVICENET, PROFIBUS DP, INTERBUS CURRENT CONSUMPTION: INTERNAL SERIAL INTERFACE - 300 OUTPUTS - 8A MAX. SUPPLY VOLTAGE: OPERATING WITH SINGLE SUPPLY: 24 VDC ±10% OPERATING WITH INTERNAL SLIM ON SEPARATE SUPPLY: 24 VDC ±10% WEIGHT: OPERATING TEMPERATURE: NEMA 4 WITH VALVES BUILT TO WASHDOWN
Abrir o catálogo na página 13
ADDRESSABLE VALVE SHOWN WITH 92 SERIES ADDRESSABLE V A L V E S B E N E F I T S 1. Ability to add a remote valve to a bus network 2. Ease of installation 3. Reduction in wiring costs 4. Washdown capability INPUTS 1 Single or Double Solenoid Valve
Abrir o catálogo na página 14
VOTTAGE / CURRENT: 24 VDC / .225A PER CHANNET (5.4 WATTS PER CHANNET) SUPPTY VOTTAGE: OPERATING WITH SINGTE BUS SUPPTY: 24 VDC ±10% ( WHERE PROTOCOT ATTOWS ) OPERATING WITH SEPARATE POWER SUPPTY FOR VATVES AND INPUTS: 24 VDC ±10% HIGH TEMPERATURE APPTICATIONS: CONSUTT FACTORY AVAITABTE VATVES: DESIGNED TO MEET NEMA 4 WITH VATVES BUITT TO WASHDOWN MOD INPUT CONNECTOR ( CIPTICINAL ) - SINGLE REVERSE KEYWAY _ DIMENSIONS ShOWN NETWORK COMMUNICATION CONNECTOR (STANDARD) EXTERNAL POWER DOUBLE KEYWAY
Abrir o catálogo na página 15
P.O. Box 111 30569 Beck Road Wixom, Mi. 48393-7011 Tel: 1-800-MAC VLVS Tel: 1-248-624-7700 Fax: 1-248-624-0549 E-mail: mac@macvalves.com WebSite: www.macvalves.com MAC VALVES EUROPE, INC. Rue Marie Curie, 12 B-4431 Ans (Liege) Belgium MAC VALVES PACIFIC, INC. P.O. Box 12221 Penrose, Auckland New Zealand MAC VALVES, INC. 5275 Ann Arbor Rd. Dundee, Mi. 48131 Installation and Service Precautions: A. Do not install or service MAC valves without first making sure both air and electrical power to the machine are off and that all air has been completely bled from the system. B. MAC valves should...
Abrir o catálogo na página 16Todos os catálogos e folhetos técnicos MAC Valves
-
PV03 Series
3 Páginas
-
Series 37
7 Páginas
-
Series 38
15 Páginas
-
Series 72
4 Páginas
-
Series 77
6 Páginas
-
Series 100
13 Páginas
-
Series 200
18 Páginas
-
Series 1100
5 Páginas
-
92 MAConnect
20 Páginas
-
82 series
24 Páginas
-
MAC Advantage Brochure
16 Páginas
-
CIRCUIT BAR CATALOG
288 Páginas
-
Proportional pressure controller
89 Páginas
-
CURRENT TECHNOLOGY CATALOG
359 Páginas
-
NEW TECHNOLOGY CATALOG
298 Páginas
-
77 series
6 Páginas
-
82 MAConnect
24 Páginas
-
Bullet Valve
24 Páginas
-
38 series
15 Páginas
-
33 series
5 Páginas
-
32 series
17 Páginas
-
35L
14 Páginas
-
31 series
9 Páginas
-
700
10 Páginas
-
1100