Excertos do catálogo

Direct solenoid and solenoid pilot operated valves Series 38 Individual mounting Sub-base non “plug-in” Sub-base “plug-in” Series Sub-base/ manifold base non “plug-in” with latching solenoid Sub-base/ manifold base “plug-in” with latching solenoid Manifold mounting Manifold base “plug-in” Sub-base/ manifold base non “plug-in” with latching solenoid Sub-base/ manifold base “plug-in” with latching solenoid Manual operator Bonded spool 400 92 SERIES FEATURES • High force MACSOLENOID®. • Integral 4-way pilot design. • Internal or external pilot. • Normally open or normally closed function. • Universal function (external pilot). • Rectified AC voltage. • Latching solenoid technology. Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Abrir o catálogo na página 1
Direct solenoid and solenoid pilot operated valves Port size Individual mounting OPERATIONAL BENEFITS 1. 3-way valve with 4-way integral pilot. 2. 10 mm valve (stacks on 16.5 mm centers). 3. High flow (up to 1.2 Cv). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Port size Valve less base Universal valve Note : Above codes are for side port. STANDARD SOLENOID OPERATOR ® Wire length Manual operator Electrical connection Non-locking recessed Locking recessed Flying leads Flying leads with light MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/Diode MAC...
Abrir o catálogo na página 2
Series 38 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Internal Pilot : 20 to 120 PSI External Pilot : Vacuum to 120 PSI Pilot pressure : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : 1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) Class A wire (#22 AWG x 18), continuous duty Voltage range : Response times : • BSPP threads Dimensions shown are metric (mm) EP MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. Consult “Precautions” page 327 before use, installation or service of MAC Valves..
Abrir o catálogo na página 3
Direct solenoid and solenoid pilot operated valves Port size Individual mounting Sub-base “plug-in” OPERATIONAL BENEFITS 1. 3-way valve with 4-way integral pilot. 2. 10 mm valve (stacks on 16.5 mm centers). 3. High flow (up to 1.2 Cv). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Port size Valve less base Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR ® Manual operator Electrical connection Non-locking recessed Locking recessed Base plug-in Base plug-in with light Base plug-in with rectifier & light & ground Note : AC...
Abrir o catálogo na página 4
Series 38 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Internal Pilot : 20 to 120 PSI External Pilot : Vacuum to 120 PSI Pilot pressure : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : 1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv) Class A continuous duty, #22 AWG x 12 base leads Voltage range : Response times : • BSPP threads Dimensions shown are metric (mm) 76.0 WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. Consult “Precautions” page 327 before use, installation or...
Abrir o catálogo na página 5
Direct solenoid and solenoid pilot operated valves Port size Manifold mounting Manifold base “plug-in” OPERATIONAL BENEFITS 1. 3-way valve with 4-way integral pilot. 2. 10 mm valve (stacks on 16.5 mm centers). 3. High flow (up to 1.2 Cv). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Port size Valve less base Tube receptacle Note : Above codes are for side port. STANDARD SOLENOID OPERATOR ® Manual operator Electrical connection Non-locking recessed Locking recessed Base plug-in Base plug-in with light Base plug-in with rectifier & light & ground Note :...
Abrir o catálogo na página 6
Series 38 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Internal Pilot : 20 to 120 PSI External Pilot : Vacuum to 120 PSI Pilot pressure : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : 1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv) Class A continuous duty, #22 AWG x 12 base leads Voltage range : Response times : • BSPP threads Dimensions shown are metric (mm) 4.0 MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI....
Abrir o catálogo na página 7
Direct solenoid and solenoid pilot operated valves Port size Individual/Manifold mounting Sub-base/ manifold base non “plug-in” with latching solenoid OPERATIONAL BENEFITS 1. 3-way valve with 4-way integral pilot. 2. 10 mm valve (stacks on 16.5 mm centers). 3. High flow (up to 1.2 Cv). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Port size Valve less base Universal valve Tube receptacle Note : Above codes are for individual base and side port. LATCHING SOLENOID OPERATOR ® Wire length Manual operator Electrical connection** 2 Wire Flying leads 4 Wire...
Abrir o catálogo na página 8
Series 38 TECHNICAL DATA Compressed air, vacuum, inert gases Pressure range : Internal Pilot : 20 to 120 PSI External Pilot : Vacuum to 120 PSI Pilot pressure : Not required, if used select a medium aniline point lubricant (between 180°F and 210°F) Temperature range : 1/8" bottom port: (1.2 Cv) - 1/8" side port: (1.0 Cv) - 1/4” tube receptacle: (0.85 Cv) Class A wires (#22 AWG x 18), continuous duty Voltage range : Response times : • BSPP threads Individual base Manifold base 1/8" TAPPED OR 1/4" O.D. TUBE FITTING MODEL WIXOM, MI. USA LIEGE, BELGIUM AUCKLAND, N.Z. WIXOM, MI. USA LIEGE,...
Abrir o catálogo na página 9
Direct solenoid and solenoid pilot operated valves Port size Individual/Manifold mounting Sub-base/ manifold base “plug-in” with latching solenoid OPERATIONAL BENEFITS 1. 3-way valve with 4-way integral pilot. 2. 10 mm valve (stacks on 16.5 mm centers). 3. High flow (up to 1.2 Cv). 4. Fast, repeatable response times. 5. Maximum shifting forces in both directions. Port size Valve less base Universal valve Tube receptacle Note : Above codes are for individual base and side port. LATCHING SOLENOID OPERATOR ® Manual operator Electrical connection** Base/Manifold Plug-in Base/Manifold Plug-in...
Abrir o catálogo na página 10Todos os catálogos e folhetos técnicos MAC Valves
-
PV03 Series
3 Páginas
-
Series 37
7 Páginas
-
Series 38
15 Páginas
-
Series 72
4 Páginas
-
Series 77
6 Páginas
-
Series 100
13 Páginas
-
Series 200
18 Páginas
-
Series 1100
5 Páginas
-
92 MAConnect
20 Páginas
-
82 series
24 Páginas
-
MAC Advantage Brochure
16 Páginas
-
CIRCUIT BAR CATALOG
288 Páginas
-
Proportional pressure controller
89 Páginas
-
CURRENT TECHNOLOGY CATALOG
359 Páginas
-
NEW TECHNOLOGY CATALOG
298 Páginas
-
77 series
6 Páginas
-
Serial interface
16 Páginas
-
82 MAConnect
24 Páginas
-
Bullet Valve
24 Páginas
-
33 series
5 Páginas
-
32 series
17 Páginas
-
35L
14 Páginas
-
31 series
9 Páginas
-
700
10 Páginas
-
1100
5 Páginas