UPA
1 / 118Páginas

{{requestButtons}}

Excertos do catálogo

UPA - 1

Type Series Booklet 3400.5/6--10 50 Hz Submersible Borehole Pumps Applications -- Drinking and service water supply -- Irrigation and spray irrigation -- Lowering and maintaining ground water levels -- Pressure boosting -- Fountains -- Mining, offshore, tank farms -- Building services systems -- VDS sprinkler systems Operating Data Capacity Q up to 840 m3/h (233 l/s) Head H up to 480 m Temperature of fluid handled t up to +50 °C Speed n 2900 rpm Supply voltage U up to 10,000 V Design Single-- or multistage centrifugal pumps in pump shroud or in ring--section design. Radial or mixed flow hydraulic systems; reduced impeller diameters also available in some cases. The stage casings of radial pumps are connected by metal straps, those of mixed flow pumps by stud bolts. Suction casing fitted between pump and motor. Suction casing equipped with strainer to protect the pump from coarse particles in the fluid. Pumps with check valve or connection branch on option. Available with threaded or flanged end on option. Particularly suitable for vertical installation in narrowdeep wells. Pump Designation (Example) UPA 200 B -- 80 / 5 b Type series Minimum well diameter (mm) (for ex.: 200 mm = 8 inches) Design status Capacity Qopt (m3/h) -- (4 up to 10 inches) 1) (l/s) -- (12 inches and above) Number of stages Reduced impeller diameters 1) UPA 200 -11 + 14: Q in l/s. Motor Designation (Example) UMA 250 D 110 / 2 1 Type series Well diameter (mm) (for ex. 250 mm = 10 inches) Design status Rated power PN (kW) Number of poles Winding insulation Certification Quality management certified to ISO 9001 Submersible Borehole Pumps S 100D, UPA 100C, UPA 150C, UPA 200, UPA 200B, UPA 250C, UPA 300, UPA 350, BSX -- BSF, UPZ Available automation products: • Hyamaster (UPA 200 -- UPA 350) • hyatronic (UPA 200 -- UPA 350) • switch gear (S 100D -- UPA 350) Complete Range The complete submersible borehole pump range comprises pump models for flow rates up to Q = 2500 m3/h (695 l/s) and heads up to H = 1500 m. The submersiblemotor range covers sizes for power ratings up to P = 3500 kW and voltages up to U = 10,000 V for 50 and 60 Hz. In addition, a special range is available which features submersible motors with a higher number of poles.

Abrir o catálogo na página 1
UPA - 2

50 Hz Submersible Borehole Pumps 2 Contents Page The Submersible Borehole Pump Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation with Soft Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Operation with Frequency Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Typical Installation Positions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Submersible Borehole Pump Selection for Deep Wells . . . ....

Abrir o catálogo na página 2
UPA - 3

50 Hz Submersible Borehole Pumps 3 What can you expect from the “Submersible Borehole Pumps Booklet”? The information provided can help you make a -- quick -- first rough selection -- on your own to find a suitable KSB submersible borehole pump for your application.We have kept the volume of the catalogue down to what we think is the absolute minimum. For the 4 to 14 inch range, you will find the following information on the pump selected: -- pump series, size and number of stages, -- motor series, size, power, amperage, and allowable temperature, -- starting method, supply voltage and type...

Abrir o catálogo na página 3
UPA - 4

50 Hz Submersible Borehole Pumps 4 The Submersible Borehole Pump Range " S 100D (4 inch) p. 11 -- 22 " UPA 100C (4 inch) p. 23 -- 32 " UPA 150C (6 inch) p. 33 -- 56 UPA 200 " (8/10 inch) p. 57 -- 65 " UPA 200B (8/10 inch) p. 65 -- 69 UPV 150S (6 inch) on request " UPZ BSX - BSF ( 16 inch) p. 91 -- 98 on request " UPA 300, 350 (12/14 inch) p. 77 -- 90 " UPA 250C (8/10 inch) p. 70 -- 76 " UPV 200 (8 inch) on request

Abrir o catálogo na página 4
UPA - 5

Voltage [%] Time [s] Run--up Operation Run--down 4s 4s 120 100 80 60 40 20 0 50 Hz Submersible Borehole Pumps 5 Operation of KSB submersible motor pumps with soft starters Soft starter electronically reduce the incoming line voltage and, hence, the initial starting torque and starting current of electric motors. During run--up they gently ramp up the applied voltage to the motor. In the case of submersible motors, the extremely slim design and consequential small moments of inertia result in special characteristics, which differ strongly from normal asynchronous motors. Effects on...

Abrir o catálogo na página 5
UPA - 6

50 Hz Submersible Borehole Pumps 6 Pump Operation with Frequency Inverter In principle, the motors of submersible borehole pumps can also be run on a frequency inverter. As submersible motors differ from conventional standardized motors in terms of bearings, moment of inertia, insulation, temperature increase, loss distribution and heat distribution, the following parameters must be observed: -- Maximum allowable acceleration time (start ramp) -- Maximum allowable deceleration time (stop ramp) -- Minimum frequency -- Maximum operating frequency -- Maximum permissible voltage increase...

Abrir o catálogo na página 6
UPA - 7

50 Hz Submersible Borehole Pumps 7 Typical Installation Positions a) Vertical Installation (deep well, pump sump, etc.) CAUTION: The construction of the well head must meet the relevant regulations of the competent authorities! The unitmust never be installed with its suction strainer exactly at the level of the well screen / filter! Before installing the unit in narrow deep wells we recommend to check narrow boreholes for dimensional accuracy over their entire length, e.g. by inserting a pipe of the length and biggest outside diameter of the pump unit. Sharp bends or bottlenecks can make...

Abrir o catálogo na página 7
UPA - 8

50 Hz Submersible Borehole Pumps 8 Submersible Borehole Pump Selection for Deep Wells Pump Selection The following data are required for a first rough selection of a submersible borehole pump: -- Capacity Q in m3/h (l/s) -- Pressure at well head HA in m -- Well diameter in inches or mm -- Temperature of fluid handled tA in °C -- Pump head HP in m While Q, HA, Dand tA are usually specified by the customer, the head HP to be developed by the pump needs to be calculated. There are two typical applications to be considered (see the drawing on the right): 1. Pumping into an open overhead tank HP...

Abrir o catálogo na página 8

Todos os catálogos e folhetos técnicos KSB

  1. RPH

    2 Páginas

  2. HERA-BD

    2 Páginas

  3. SISTO-10

    24 Páginas

  4. BOA-CVE H

    2 Páginas

  5. UPA

    104 Páginas

  6. HPK-L

    2 Páginas

  7. KWP

    2 Páginas

  8. Etachrom L

    2 Páginas

  9. Amarex N

    2 Páginas

  10. Etaline-R

    2 Páginas

  11. BOA-R

    16 Páginas

  12. TRIODIS 150

    2 Páginas

  13. Cervomatic EDP.2

    10 Páginas

  14. Etabloc SYT

    2 Páginas

  15. ACTELEC 31 to 1600

    18 Páginas

  16. Amaclean

    12 Páginas

  17. Amacan S

    2 Páginas

  18. Amacan P

    2 Páginas

  19. Amacan K

    2 Páginas

  20. Ama-Drainer-Box

    2 Páginas

  21. Ama-Drainer 80/100

    20 Páginas

  22. Amar-Drainer 4../5

    16 Páginas

  23. UGS

    12 Páginas

  24. ACTELEC EZ SQ

    20 Páginas

  25. ACTELEC SQ AUMA

    14 Páginas

  26. ACTELEC 31 to 800

    12 Páginas

  27. ACTAIR 1.5 to 1600

    20 Páginas

  28. PumpMeter

    12 Páginas

  29. KSB Sonolyzer

    5 Páginas

  30. Etachrom L

    40 Páginas

  31. Etanorm/Etabloc

    70 Páginas

  32. AKG-A/AKGS-A

    12 Páginas

  33. Amamix

    2 Páginas

  34. Amaprop

    2 Páginas

  35. HQ

    2 Páginas

  36. BOAX-CBV13

    3 Páginas

  37. Ama-Porter F, S

    2 Páginas

  38. Magnochem

    2 Páginas

  39. Secochem Ex

    2 Páginas

  40. Hya-Solo D

    44 Páginas

  41. HGB, HGC

    4 Páginas

  42. GZ 9

    2 Páginas

  43. Etaseco

    2 Páginas

  44. Etanorm

    2 Páginas

  45. Etaline

    2 Páginas

  46. CTN / -H

    2 Páginas

  47. CINCP / CINCN

    2 Páginas

  48. CHTC

    2 Páginas

  49. Calio S

    2 Páginas

  50. AMADS

    2 Páginas

  51. Ama-Drainer Box

    2 Páginas

  52. YNK

    2 Páginas

  53. RHR/RVR

    2 Páginas

  54. RHM

    2 Páginas

  55. HGC

    2 Páginas

  56. CHTD

    2 Páginas

  57. Danais 150/300

    2 Páginas

  58. RPHb

    2 Páginas

  59. MegaCPK

    2 Páginas

  60. RPH-V

    2 Páginas

  61. RDLO

    2 Páginas

  62. Multitec

    2 Páginas

  63. INVCP

    2 Páginas

  64. SuPremE

    2 Páginas

Catálogos arquivados

  1. Handle S series

    8 Páginas

  2. MR 25 to 1600

    16 Páginas

  3. MN

    4 Páginas

  4. MA

    4 Páginas

  5. DYNACTO 12 to 400

    16 Páginas

  6. ACTO 25 to 12500

    16 Páginas

  7. ACTAIR 1,5 to 1600

    20 Páginas

  8. MAT-P

    4 Páginas

  9. BOA-CVE

    16 Páginas

  10. VTS

    4 Páginas

  11. BOA-RVK

    4 Páginas

  12. BOA-Control IMS

    8 Páginas

  13. HERA BD

    6 Páginas

  14. ZJSVA/ ZXSVA

    6 Páginas

  15. BOACHEM

    4 Páginas

  16. BOA-H

    2 Páginas

  17. BOA-SuperCompact

    8 Páginas

  18. LSA-S

    4 Páginas

  19. HGM

    4 Páginas

  20. Trialine

    12 Páginas

  21. Trialine Z

    12 Páginas

  22. Riovar/Riovar Z

    16 Páginas

  23. Rio-Eco/Z

    24 Páginas

  24. Riotherm

    4 Páginas

  25. Rio/Rio Z

    32 Páginas

  26. PHZ

    15 Páginas

  27. Ixo

    4 Páginas

  28. CTN

    4 Páginas

  29. Ama-Porter

    24 Páginas

  30. Ama-Porter ICS

    16 Páginas

  31. Amaprop

    4 Páginas

  32. Omega / Omega V

    56 Páginas