Excertos do catálogo

Automation products available: • PumpExpert • PumpDrive (MM) • Hyamaster • hyatronic Type series booklet 50 and 60 Hz 1167.5/10-10 G2 EtablocR Close-coupled pumps Fields of application Water supply Cooling water Sprinkling Swimming pool water Irrigation Sea water Drainage Fire-fighting water Heating systems Brackish water Air-conditioning systems Condensate Drinking water Brine Service water Oils Hot water Cleaning agents Operating data 50 Hz 60 Hz Q up to 650 m3/h, 180 l/s up to 740 m3/h, 205 l/s H up to 101 m up to 97 m t -30 up to +140 °C P2 1) up to 16 bar 1) see pressure/temperature limits, page 5 Designation Etabloc G (N) 50-160 / 75 2 Type series Casing material e.g. JL1040 2) Stub shaft design with standardized motor Pump size, e.g. Motor rating: kW x 10 (e.g. 7.5 kW) Number of motor poles 2) to EN 1561 = GJL-250 Shaft seal Mechanical seal to EN 12756. Design/Variants Volute casing pumps, single-stage 3), with ratings to EN 733. The shaft is fitted with a replaceable shaft sleeve in the shaft seal area. Volute casing and impeller supplied with replaceable wear rings 4). 3) Etabloc 32-23 double-stage 4) except Etabloc 25-20 and 32-23 Etabloc GN, MN, SN, BN, CN Pump and motor flanged together to form a close-coupled unit, with standardized motor. Pump shaft and motor shaft are rigidly connected. Etabloc G, M Pump and motor flanged together to form a close-coupled unit, with common shaft. Drive Standard version Etabloc N Surface-cooled KSB-IEC three-phase squirrel cage motor. Winding: 50Hz up to 2.2 kW 220-240 V/380-420 V up to 3 kW 380-420 V/660-725 V 60Hz up to 2.6 kW 440-480 V up to 3.6 kW 440-480 V Design: up to 4 kW IM V1 up to 5.5 kW IM V15 Enclosure: IP 55 Thermal class: F with temperature sensors: 3 PTC resistors Operating mode: continuous operation S1 or surface-cooled three-phase squirrel cage motor as described above, but West European brand to KSB’s choice. Flameproof version Etabloc N Surface-cooled IEC three-phase squirrel cage motor, West European brand to KSB’s choice. Winding: 50Hz up to 1.85 kW 220-240 V/380-420 V ab 2.5 kW 380-420 V/660-725 V Disign: up to 3.3 kW IM V1 for 4.6 kW and above IM V15 Enclosure: IP 55 or IP 54 Type of protection: EExe II Thermal class: T3 Operating mode: continuous operation S1 Standard version Etabloc G, M Surface-cooled KSB three-phase squirrel cage motor with longer shaft and special flange. Winding: 50Hz up to 2.2 kW: 220-240 V / 380-420 V for 3 kW and above: 380-420 V / 660-725 V 60Hz up to 2.6 kW 440-480 V for 3.6 kW and above440-480 V Design: up to 4 kW: ohne Fuß for 5.5 kW:and above with foot Enclosure: IP 55 Thermal class: F mit Temperaturfühler: 3 Kaltleiter Operating mode: continuous operation S1 Contact guard: Cover plates on drive lantern to EN 294 Certification Certified quality management ISO 9001.
Abrir o catálogo na página 1
Etabloc 4 Materials Etabloc G, GN Etabloc M, MN Etabloc BN Volute casing Grey cast iron JL1040 1) Grey cast iron JL1040 1) Tin bronze CC480K-GS 3) Discharge cover Grey cast iron JL1040 1) Grey cast iron JL1040 1) Tin bronze CC480K-GS 3) Impeller Grey cast iron JL1040 1) Tin bronze CC480K-GS 3) Tin bronze CC480K-GS 3) Casing wear rings Grey cast iron GG Grey cast iron / Leaded bronze GG/CC495K-GS 3) Leaded bronze CC495K-GS 3) Shaft Tempering steel C45N Tempering steel C45N Chrome nickel molybdenum steel 1.4571 Shaft sleeve Chrome nickel molybdenum steel 1.4571 Chrome nickel molybdenum steel...
Abrir o catálogo na página 4
1211:173/1 1.4408 JL 1040 1) 1.4408 3) JS 1025 2) JL 1040 1) Etabloc 5 Pressure and Temperature Limits Etabloc Product temperature 1)4) Discharge pressure p 2 2) Test pressure 3) G,GN -30 °C up to + 140 °C up to 21 bar M, MN -30 °C up to + 140 °C 5) up to 21 bar SN -30 °C up to + 140 °C up to 25 bar BN -30 °C up to + 140 °C 10 bar up to 13 bar CN -30 °C up to + 140 °C 5) up to 21 bar 1) For hot water heating systems to DIN 4752, section 4.5, application limits must be observed. 2) The sum of inlet pressure and shut-off head must not exceed the values shown in the diagram. 3) The casing...
Abrir o catálogo na página 5
Etabloc 6 Materials Casing/Impeller Shaft seal Mechanical seal Medium handled Application limits Comments G, GN M, MN SN BN CN 6 9 10 11 12 Water Brackish water 3) t ± 25 °C p ±10 bar X X BN10 Cast CrNiMo steel possible Condensate 2) t ± 120 °C p ± 10 bar X X G11, GN11 Condensate, unconditioned t 120 °C p 10 bar X X CN11 Cooling water 1) (no anti-freezes) t 60 °C 6) p 10 bar X X G10, GN10 open circuit: M 10/MN 10 required Cooling water pH value 7.5 (with anti-freeze) t 30-110°C p 10 bar X X G11, GN11 open circuit: M 11/MN 11 required Dam water 1] t 60 °C 6) p 10 bar X X MN10 If...
Abrir o catálogo na página 6
Etabloc 7 Materials Casing/Impeller Shaft seal Mechanical seal Medium handled Application limits Comments G, GN M, MN SN BN CN 9 10 12 Oils/Emulsions Diesel oil, fuel oil EL t 60 °C p 10 bar X X SN10 Grey cast iron possible, unless specific standards have to be observed Lubricating oil, turbine oil, does not apply to SDF oils (hardly inflammable) t 80 °C p 10 bar X X SN10 Drilling/Grinding emulsion t 60 °C p 10 bar X X G9, GN9 If specified ”without” internal primer, contact KSB. Grey cast iron possible, unless specific standards have to be observed Oil--water emulsion t 60 °C p 16 bar X X...
Abrir o catálogo na página 7
Etabloc 8 Etabloc G, M 25-20.1, 32-23.1 Materials Casing/Impeller Shaft seal Mechanical seal Medium handled Application limits Comments G M 9 10 11 Water Condensate 2) t 110 °C p 10 bar X X G11 Cooling water 1) (no anti-freezes) t 60 °C 6) p 10 bar X X G10 open circuit: M 10/MN 10 required Cooling water pH value 7.5 (with anti-freeze) t -30-+110 °C p 10 bar X X G11 open circuit: M 11/MN 11 required Dam water 1] t 60 °C 6) p 10 bar X X M10 If solids-laden: contact KSB Drinking water 1] t 60 °C 7) p 10 bar X X M11 Fire-fighting water 1] t 60 °C 6) p 10 bar X X M10 Cast CrNiMo steel possible...
Abrir o catálogo na página 8
1165:21/4 1167:72 1167:22/5 1165:62/2 1167:70 1167:71 motor size 132 = 5.5 kW up to 180 = 22 kW Etabloc GN, MN, BN1), SN1) motor size 132 = 5.5 kW up to 180 = 22 kW for Etabloc CN contact KSB motor size 112 = 4 kW motor size 132 = 5.5 kW up to 180 = 22 kW 2-poles 4-poles 1165:60 1167:68 1167:69 1167:73 1167:74 For vertical installation, a vent valve must be provided to prevent dry-running of the mechanical seal. For vertical installation, a vent valve must be provided to prevent dry-running of the mechanical seal. As-delivered condition Horizontal installation, attachment below 1) Volute...
Abrir o catálogo na página 12Todos os catálogos e folhetos técnicos KSB
-
RPH
2 Páginas
-
HERA-BD
2 Páginas
-
SISTO-10
24 Páginas
-
BOA-CVE H
2 Páginas
-
UPA
104 Páginas
-
HPK-L
2 Páginas
-
KWP
2 Páginas
-
Etachrom L
2 Páginas
-
Amarex N
2 Páginas
-
Etaline-R
2 Páginas
-
BOA-R
16 Páginas
-
TRIODIS 150
2 Páginas
-
Cervomatic EDP.2
10 Páginas
-
Etabloc SYT
2 Páginas
-
Type Series Booklet
22 Páginas
-
Type Series Booklet
14 Páginas
-
ACTELEC 31 to 1600
18 Páginas
-
1/4 turn ACTELEC LEA and LEB
4 Páginas
-
ACTELEC 31 to 800 (BERNARD)
12 Páginas
-
Amaclean
12 Páginas
-
Amacan S
2 Páginas
-
Amacan P
2 Páginas
-
Amacan K
2 Páginas
-
Ama-Drainer-Box Mini
2 Páginas
-
Ama-Drainer-Box
2 Páginas
-
Ama-Drainer® N –
2 Páginas
-
Ama-Drainer 80/100
20 Páginas
-
LevelControl Basic 2
36 Páginas
-
Amar-Drainer 4../5
16 Páginas
-
UGS
12 Páginas
-
ACTELEC SG05.1 to SG12.1
8 Páginas
-
ACTELEC EZ SQ
20 Páginas
-
ACTELEC SQ AUMA
14 Páginas
-
ACTELEC 31 to 800
12 Páginas
-
ACTAIR 1.5 to 1600
20 Páginas
-
Original KSB Spare Parts Kits
2 Páginas
-
PumpMeter
12 Páginas
-
KSB Sonolyzer
5 Páginas
-
Etachrom L
40 Páginas
-
Etanorm/Etabloc
70 Páginas
-
Ama-Porter CK Pump Station
18 Páginas
-
AKG-A/AKGS-A
12 Páginas
-
BOA-Control/ BOA‑Control IMS
16 Páginas
-
Amamix
2 Páginas
-
Amaprop
2 Páginas
-
HQ
2 Páginas
-
BOAX-CBV13
3 Páginas
-
Ama-Porter F, S
2 Páginas
-
Magnochem
2 Páginas
-
Secochem Ex
2 Páginas
-
Hya-Solo D
44 Páginas
-
HGB, HGC
4 Páginas
-
GZ 9
2 Páginas
-
Etaseco
2 Páginas
-
Etanorm
2 Páginas
-
Etaline
2 Páginas
-
CTN / -H
2 Páginas
-
CINCP / CINCN
2 Páginas
-
CHTC
2 Páginas
-
Calio S
2 Páginas
-
AMADS
2 Páginas
-
Ama-Drainer Box
2 Páginas
-
YNK
2 Páginas
-
RHR/RVR
2 Páginas
-
RHM
2 Páginas
-
HGC
2 Páginas
-
CHTD
2 Páginas
-
Danais 150/300
2 Páginas
-
RPHb
2 Páginas
-
MegaCPK
2 Páginas
-
CHTR sted Power in Seawater
8 Páginas
-
RPH-V
2 Páginas
-
RDLO
2 Páginas
-
Multitec
2 Páginas
-
Magnochem with leakage barrier
2 Páginas
-
INVCP
2 Páginas
-
SuPremE
2 Páginas
-
Etabloc, Etanorm-R, Etachrom
2 Páginas
-
Amarex KRT, Submersible Motor Pump
2 Páginas
-
The New Calio. Expertise
16 Páginas
-
SALINO® Pressure Center
12 Páginas
-
The Range of Valves
74 Páginas
-
Pumps and Automation
66 Páginas
Catálogos arquivados
-
Handle S series
8 Páginas
-
MR 25 to 1600
16 Páginas
-
MN
4 Páginas
-
MA
4 Páginas
-
ENNACTO 200 to 12500
20 Páginas
-
DYNACTO 12 to 400
16 Páginas
-
ACTO 25 to 12500
16 Páginas
-
ACTAIR 1,5 to 1600
20 Páginas
-
MAT-P
4 Páginas
-
ACTELEC 31 to 800 (BERNARD)
12 Páginas
-
BOA-CVE
16 Páginas
-
Ball Valve KHG DN 50-80
4 Páginas
-
Ball Valve KHG PN 250
4 Páginas
-
Ball Valve KHG DN 150-1200
8 Páginas
-
Ball Valve KHG DN 100
4 Páginas
-
Ball Valve KHG DN 15-40
6 Páginas
-
SICCA GTF 800-2500
8 Páginas
-
VTS
4 Páginas
-
BOA-RVK
4 Páginas
-
BOA-Control IMS
8 Páginas
-
HERA BD
6 Páginas
-
ZJSVA/ ZXSVA
6 Páginas
-
BOACHEM
4 Páginas
-
BOA-H
2 Páginas
-
BOA-SuperCompact
8 Páginas
-
LSA-S
4 Páginas
-
HGM
4 Páginas
-
Trialine
12 Páginas
-
Trialine Z
12 Páginas
-
Type Series Booklet S 100D 60 Hz
16 Páginas
-
Riovar/Riovar Z
16 Páginas
-
Rio-Eco/Z
24 Páginas
-
Riotherm
4 Páginas
-
Rio/Rio Z
32 Páginas
-
PHZ
15 Páginas
-
Ixo
4 Páginas
-
CTN
4 Páginas
-
UPA
118 Páginas
-
Ama-Porter
24 Páginas
-
Ama-Porter ICS
16 Páginas
-
Brochure HPK / HPK-L
4 Páginas
-
SPY-2-Page Product
2 Páginas
-
Operating Instructions Rotex,
16 Páginas
-
Amaprop
4 Páginas
-
Type series booklet Amaline 50 Hz
28 Páginas
-
Brochure "Waste water pumps"
2 Páginas
-
Omega / Omega V
56 Páginas
-
Product Introduction MK
4 Páginas
-
Product Introduction Etanorm
4 Páginas
-
Type Series Booklet Etaline - Industry
58 Páginas
-
Type series booklet CPKN
16 Páginas
-
Amacan S 2-page product description
2 Páginas
-
Sewatec double-sided product leaflet
2 Páginas
-
Axially split volute casing pump
2 Páginas
-
KSB - The company that keeps it moving
26 Páginas