Excertos do catálogo

Viscosity-Compensated Flowmeters and Switches Measuring range: oil 0.01 - 0.07 ... 8 - 80 l/min Basic accuracy: ± 4 % of full scale Connection: G ¼ ... G 1 female ¼" ... 1" NPT female Material: brass, stainless steel KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, RUSSIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)619
Abrir o catálogo na página 1
Viscosity-Compensated Flowmeters and Switches Model VKM Technical Details Body: Screwed fitting: Float: Orifice: Spring: Magnet: Seals: Max. temperature: Max. pressure: Electrical connection: Electrical switching values: Description The flowmeters and switches model VKM have a spring-loaded float, which slides within a cylindrical measuring tube and has an integral orifice which is believed to be unique. This and other design features means that it has for the first time become possible to create a flowmeter and switch which fully compensates for viscosity and to a large extent for density...
Abrir o catálogo na página 2
ATEX contact ...F0: ATEX N/O contact type 41R57 ...G0 and GG: Viscosity-Compensated Flowmeters and Switches Model VKM c) In Zone 21 (dust hazard, category 2D) in the explosion groups IIIA and IIIB d) In Zone 22 (dust hazard, category 3D) in the explosion groups IIIA and IIIB <g> II 2 G Ex mb IICT6 Gb <g> II 2 D Ex mb IICT80°C Db max. 250 VAC/1,5 A /100 VA ATEX changeover contact type 41R57U ...H0 and HH: Hysteresis: Protection: approx. 3.5 mm float movement IP 65 (electrical contact) IP 54 (side indicator) Order Details Viscosity-compensated flow switches model: VKM-1. Measuring range l/min...
Abrir o catálogo na página 3
Viscosity-Compensated Flowmeters and Switches Model VKMOrder Details (continued) Viscosity-compensated flowmeter model: VKM-2... Measuring range l/min oil * Pressure loss refers to water ** Viscosity range 70 ... 400 mm2/s * Pressure loss refers to water ** Viscosity range 70 ... 400 mm2/s No responsibility taken for errors; subject to change without prior notice.
Abrir o catálogo na página 4
Viscosity-Compensated Flowmeters and Switches Model VKMOrder Details (continued) Viscosity-compensated flowmeter with evaluating electronics model: VKM-7... Measuring range l/min oil approx. * Pressure loss refers to water ** Viscosity range 70 ... 400 mm2/s * Pressure loss refers to water ** Viscosity range 70 ... 400 mm2/s No responsibility taken for errors; subject to change without prior notice.
Abrir o catálogo na página 5
Viscosity-Compensated Flowmeters and Switches Model VKM Switching output: Analogue output: Power supply: indication, 5-digit, Bargraph indication, 2 changeover contacts, Analogue output 0(4) - 20 mA and 0 - 10 V Electr. connection: With this version our proven evaluating electronics ADI (see also data sheet ADI-1) in a field housing are fitted to the flowmeter. Important! The max. upper range values are approximately 10 % lower than for other types. VKM versions Five different versions are available VKM-1... VKM-2... Flow switches with 1 contact Flowmeters VKM-3... Flowmeters and switches...
Abrir o catálogo na página 6
Viscosity-Compensated Flowmeters and Switches Model VKM * Weight valid for: VKM-1.., VKM-2... ** with G 1 or 1" NPT No responsibility taken for errors; WWW.kobold.com 7 subject to change without prior notice.
Abrir o catálogo na página 7Todos os catálogos e folhetos técnicos KOBOLD INSTRUMENTATION
-
PSD
7 Páginas
-
RFS
2 Páginas
-
KES
7 Páginas
-
MIK
7 Páginas
-
DWF
4 Páginas
-
ATA-K
4 Páginas
-
HND-F
7 Páginas
-
AFK-G2
3 Páginas
-
HND-C
3 Páginas
-
ACM-1
6 Páginas
-
HND-R
4 Páginas
-
APM-1
6 Páginas
-
HND-T120
10 Páginas
-
MWD
21 Páginas
-
TNF
6 Páginas
-
TNS
6 Páginas
-
TWP
4 Páginas
-
TDD-1
3 Páginas
-
TWR
2 Páginas
-
TSA
2 Páginas
-
TRS
2 Páginas
-
M
23 Páginas
-
NSV
4 Páginas
-
NIR-9
5 Páginas
-
MM
13 Páginas
-
NGM
10 Páginas
-
NUS-4
5 Páginas
-
NMF
4 Páginas
-
NGR
7 Páginas
-
PLS
2 Páginas
-
PAS
22 Páginas
-
NWS
5 Páginas
-
NVI
3 Páginas
-
NV
2 Páginas
-
NTB
3 Páginas
-
NSC
4 Páginas
-
NMT
2 Páginas
-
NMC
4 Páginas
-
NKP
2 Páginas
-
NGS
8 Páginas
-
NES
2 Páginas
-
NEC
6 Páginas
-
NCW
4 Páginas
-
NBK
5 Páginas
-
LNM
2 Páginas
-
PUM
2 Páginas
-
HND-P105
8 Páginas
-
SEN-96
3 Páginas
-
MAN-RF...M21..DRM-602
4 Páginas
-
MAN-SD
4 Páginas
-
SEN-86 AUF
6 Páginas
-
SEN-3251 / 3252
3 Páginas
-
SCH
21 Páginas
-
PMP
2 Páginas
-
PAD
23 Páginas
-
DAK-1
6 Páginas
-
DAT-1
6 Páginas
-
DKB
3 Páginas
-
DKF
2 Páginas
-
DAA
2 Páginas
-
DAR
6 Páginas
-
DON-...LCD
10 Páginas
-
EPS
7 Páginas
-
BGN
6 Páginas
-
MIM
10 Páginas
-
TSK
6 Páginas
-
DUC
13 Páginas
-
VKP
2 Páginas
-
VKG
7 Páginas
-
URM
4 Páginas
-
URK
4 Páginas
-
TMU
13 Páginas
-
TME
8 Páginas
-
SMV
10 Páginas
-
PSR
5 Páginas
-
PPS
2 Páginas
-
PIT
11 Páginas
-
PEL-L
4 Páginas
-
KSM
4 Páginas
-
KDF/KDG
4 Páginas
-
KAL-D
3 Páginas
-
DWU
5 Páginas
-
DWD
4 Páginas
-
DVH / DVE
8 Páginas
-
DVZ-E
9 Páginas
-
DVK
6 Páginas
-
DUK-C
7 Páginas
-
KSR/SVN
2 Páginas
-
DSV-3
4 Páginas
-
DRH AUF
6 Páginas
-
DPL-F
4 Páginas
-
DPE-F
5 Páginas
-
DOT
5 Páginas
-
DMS
4 Páginas
-
Program summary 2018
48 Páginas
-
DON
9 Páginas