video corpo

A900 Clinometer Datasheet
1 / 2Páginas

Excertos do catálogo

A900 Clinometer Datasheet - 1

Model 900 Biaxial Clinometer The model 900 Biaxial Clinometer is an inexpensive, gravity-referenced clinometer (tiltmeter) with a wide dynamic range. Its small size and high precision make it a versatile choice for many measurement and control applications. Units are available with +/-2.5V or 0-5V DC output. Custom calibration ranges are also available on request. Units ship standard with 18” hook-up cable. Use the model 900 for industrial pitch and roll measurements, platform position and control, OEM assemblies, specialized research applications, and more. Angular Range 1 Resolution Repeatability 2 Scale Factor 3 Non-Linearity Output Channels Kz Coefficient (deg/C) Ks Coefficient (%/C) Time Constant Natural Frequency Output Impedance Power Environmental Dimensions Materials Standard Wide-Angle ±25° ±50° 0.01° 0.02° 0.02° 0.02° 10°/V 25°/V 2.5% 7% ±2.5 VDC or 0-5 VDC X-tilt, Y-tilt, Temperature 10-20 arcsec/C (typical) 0.03%/C (typical) 0.15 sec 10 Hz 270 ohms, short circuit protected +8 to +24 VDC (bipolar output); +10.5 to +26.5 VDC (0-5V output); 7mA, 250 mV ripple max, reverse polarity protected -40 to +85 C operating and storage. 0-90% humidity 2 x 2 x 0.64 inches (51 x 51 x 17 mm), 0.5 oz. (15g) Glass electrolytic sensor, fiberglass PCB *Specifications subject to change without notice on account of continued development; 1Resolution calculated at 1mV; 2Linear scale factor calculated from BFSL through calibration curve; 3Linearity calculated as max % deviation from BFSL. 0.05% linearity achievable using a polynomial Ordering Code: Jewell Instruments LLC 850 Perimeter Road, Manchester, NH 03103 sales@jewellinstruments.com • www.jewellinstruments.com • Tel (800) 227

Abrir o catálogo na página 1
A900 Clinometer Datasheet - 2

Model 900 Biaxial Clinometer Outline Diagram: * HIGH-GAIN, STANDARD GAIN OPTIONS ** WIDE-ANGLE OPTION 1 Resolution calculated a lmV 2 Linear scale factor calculated from BFSL3 Linearity calculated as max % deviation from BFSL. 0.05% linearity achievable using a polynomial Jewell Instruments LLC 850 Perimeter Road, Manchester, NH 03103

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos Jewell Instruments

  1. RMIW-D Series

    2 Páginas

  2. RMIW-L Series

    2 Páginas

  3. RMIW-S Series

    2 Páginas

  4. JDI-100/200

    9 Páginas

  5. QFA-180

    2 Páginas

  6. LCF-2000

    2 Páginas

  7. QFA-125

    2 Páginas

  8. DynamicCSG Jewell

    2 Páginas

  9. DynamicASG Jewell

    2 Páginas

  10. LSR Datasheet

    2 Páginas

  11. Sensors Catalog

    12 Páginas

  12. LCF-300 Series

    4 Páginas

  13. LCF-3500 Series

    2 Páginas

  14. LCF-2530 Series

    2 Páginas

  15. LSB Series

    2 Páginas

  16. LSMP Series

    2 Páginas

  17. LCF-200 Series

    2 Páginas

  18. ASB Series

    2 Páginas

  19. Lily Datasheet

    2 Páginas

  20. RMI-D Datasheet

    2 Páginas

  21. C4 C-Frame

    2 Páginas

  22. C2 C-Frame

    2 Páginas

  23. DXA-100/200-R

    2 Páginas

  24. • RMIW-S

    2 Páginas

  25. LCI Series

    2 Páginas

  26. QFM-180

    2 Páginas

  27. LCA-100 Series

    2 Páginas

  28. ASMP Series

    2 Páginas

  29. LSM Data Sheet

    2 Páginas

  30. LSB-R Data Sheet

    2 Páginas

  31. ASB Data Sheets

    2 Páginas