Excertos do catálogo

C HiTESTER 3506, 3505 C HiTESTER 3504-60, 3504-50, 3504-40 Electronic measuring instruments For Low Capacitance C HiTESTER 3506 Measures at 1 kHz and 1 MHz C HiTESTER 3505 Measures at 1 kHz, 100 kHz and 1 MHz For High Capacitance MLCCs C HiTESTERs 3504 -60, 3504 -50 and 3504 -40 Measures at 120 Hz and 1 kHz Ideal C meters for sorting and testing High-Speed Measurements Measurement intervals as fast as 2 ms Specifically, the 3504 Series performs constant-voltage measurements of high-capacitance MLCCs in 2 ms. High Accuracy Models 3505 and 3506 have greatly improved repeatability accuracy for very low capacitance measurements. Contact-Checking Functions Use Low-C Reject and Detection Level Monitoring functions to verify contact integrity between measurement electrodes and objects to be measured. Model 3504-60 provides four-terminal contact checking.
Abrir o catálogo na página 1
2 n High-speed measurements as fast as 2 ms (1 ms for analog measurements) High-speed testing such as with taping machines is supported by the 2 ms minimum measurement time (except FAST 120 Hz measurements). Select from FAST, NORMAL and SLOW measurement speeds. 3506, 3505 Measurement Speed Measurement Frequency Output Signal FAST NORMAL SLOW INDEX 1.1 ms 4.1 ms 13.3 ms EOM 2 ms 5 ms 14 ms 1 kHz 100 kHz 1 MHz 3504 -60, 3504 -50, 3504 -40 Measurement Speed Measurement Frequency Output Signal FAST NORMAL SLOW INDEX 8.3 ms 33.3 ms 133.3 ms EOM 10 ms 37.5 ms 146 ms INDEX 1 ms 4 ms 24 ms EOM 2 ms...
Abrir o catálogo na página 3
3 C HiTESTER 3506, 3505 Measure low-magnitude capacitors with high accuracy •Measurement parameters and frequency ranges Measurement Frequencies Range of Measurements (C, D) 120 Hz C: 0.000 fF to 15.0000 µF 3506 D: 0.00001 to 1.99999 1 kHz C: 0.000 fF to 15.0000 µF 1 MHz - - 3505 D: 0.00001 to 1.99999 100 kHz - Features of Models 3506 and 3505 C HiTESTERs n Enhanced repeat-measurement accuracy 3505 NORMAL (5 ms) Previous model FAST (5 ms) 100 60 40 20 80 0 60 −0.02% −0.01% −0.00% 0.01% 0.02% Capacitance Measurement Repeatability Accuracy 40 20 0 .3 2 −0 5% .2 7 −0 5% .2 2 −0 5% .1 7 −0 5%...
Abrir o catálogo na página 4
4 C HiTESTER 3506, 3505 S n pecifications Measurement frequencies 1 kHz, 100 kHz (only Model 3505) and 1 MHz Accuracy: ±0.01% or better Frequency shift: 1 MHz ±1%, ±2% Measurement signal level Open-circuit terminal voltage: 500 mV or 1 V Signal level accuracy: ±10% ±5 mV Output resistance: Approx. 1Ω (@1 kHz in 2.2 μF and higher ranges; @100 kHz in the 22 nF and higher ranges), approx. 20 Ω (in ranges other than the above) C: 0.000 fF to 15.0000 μF Range of measureable D: 0.00001 to 1.99999 values Q: 0.0 to 19999.9 Equivalent circuit mode Series-Parallel Equivalent Circuit mode...
Abrir o catálogo na página 5
5 C HiTESTER 3504-60, 3504-50 and 3504-40 Perform high-speed, constant-voltage testing even of high-capacitance MLCCs •Measurement parameters and frequency ranges Range of Measurements (C, D) Measurement Frequencies 120 Hz 1 kHz 100 kHz 1 MHz - - 3504-60 C: 0.9400 pF to 20.0000 mF 3504-50 D: 0.00001 to 1.99999 3504-40 •Functional differences between Models 3504 Constant-Voltage Measurement (CV) 100mV 500mV 1V -60, 3504-50 and 3504-40 Four-Terminal Interface Bin Contact Check Function Function RS-232C GP-IB EXT I/O 3504-60 3504-50 - - 3504-40 - - - - Features of Model 3504-60, 3504-50 and...
Abrir o catálogo na página 6
6 C HiTESTER 3504-60, 3504-50 and 3504-40 Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 23°C ±5%, 80% RH or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation n Measurement area: C: 0.9400 pF to 20.0000 mF; D: 0.00001 to 1.99999 n Measurement accuracy n Basic accuracy [Guaranteed accuracy: 6 months when D ≤ 0.1 D] Range No. Use the following equation to calculate the measurement accuracy. 1 Measurement accuracy = basic accuracy × B × C × D × E 2 [B: Measurement signal level coefficient] 1 at 1 V and at 500 mV, 1.5 at 100 mV 3 4...
Abrir o catálogo na página 7
Options for a wide range of applications Test sample dimensions: 1 to 10 mm Test sample dimensions: 3.5 ± 0.5 mm Test sample dimensions: 1.0 to 4.0 mm wide, maximum 1.5 mm high Measurement values, comparator results, and BIN measurement results can be printed out on the optional Printer 9442 via the standard RS-232C Interface. This Is convenient If you want to attach Inspection results to printed data. (The optional Connection Cable 9444 and AC Adapter are required to connect the • Printing method: Thermal serial dot printer • Power supply: AC Adapter 9443 or supplied NIMH battery (prints...
Abrir o catálogo na página 8Todos os catálogos e folhetos técnicos HIOKI E.E. CORPORATION
-
MR8827 Memory HiCorder
16 Páginas
-
PW6001 Power Analyzer
20 Páginas
-
Clamp On Power Logger PW3365-20
12 Páginas
-
TEMPERATURE LOGGER LR5011
8 Páginas
-
PV POWER VERIFIER LR8400-92/-93
4 Páginas
-
MEMORY HiCORDER MR8740, MR8741
12 Páginas
-
General Catalog (2014)
108 Páginas
-
HIOKI LR8410-20 Wireless Logging Station
12 Páginas
-
HIOKI RM3544/RM3548 RESISTANCE METER
12 Páginas
-
HIOKI PW3336/PW3337 Power Meter
12 Páginas
-
HIOKI DT4200 Series Digital Multimeters
12 Páginas
-
General Catalog (2013)
80 Páginas
-
HIOKI 8205-10/8206-10 MICRO HiCORDER
4 Páginas
-
HIOKI SS7012 DC SIGNAL SOURCE
4 Páginas
-
RM3544/RM3548 RESISTANCE METER
12 Páginas
-
HIOKI 3157-01 AC GROUNDING HiTESTER
4 Páginas
-
HIOKI 3490 Analog Mohm HiTester
2 Páginas
-
HIOKI RM3542 Resistance HiTester
8 Páginas
-
HIOKI PR8111/81112 Pen Recorders
4 Páginas
-
LR8431-20 MEMORY HiLOGGER
8 Páginas
-
HIOKI 327x Series Clamp On Sensors
8 Páginas
-
HIOKI FT3432 Sound Level Meter
2 Páginas
-
HIOKI FT3405/FT3406 Tacho HiTESTER
2 Páginas
-
HIOKI 3423 Lux HiTESTER
2 Páginas
-
HIOKI 8826 MEMORY HiCORDER
12 Páginas
-
HIOKI 3237 Series Digital HiTESTERs
8 Páginas
-
HIOKI 3541 Resistance HiTESTER
8 Páginas
-
HIOKI Insulation Tester Series
8 Páginas
-
HIOKI 3258 Safety HiTESTER
4 Páginas
-
HIOKI 3120 Voltage Detector
2 Páginas
-
HIOKI 3331 and 3332 Power HiTESTER
8 Páginas
-
HIOKI 3197 Power Quality Analyzer
6 Páginas
-
HIOKI 8423 MEMORY HiLOGGER Series
12 Páginas
-
HIOKI LR5000 Data Logger Series
8 Páginas
-
HIOKI IM3570 Impedance Analzyer
8 Páginas
-
HIOKI RM3543 Resistance HiTESTER
4 Páginas
-
HIOKI 8870-20 MEMORY HiCORDER
8 Páginas
-
HIOKI MR8847 MEMORY HiCORDER Series
16 Páginas
-
HIOKI MR8880-20 MEMORY HiCORDER
8 Páginas
-
HIOKI 8860-50/8861-50 MEMORY HiCORDER
16 Páginas
-
HIOKI MR8875 MEMORY HiCORDER
14 Páginas
-
HIOKI 3390 Power Analyzer
16 Páginas
-
HIOKI 3554 BATTERY HiTESTER
4 Páginas
-
HIOKI Digital HiTESTER Series
8 Páginas
-
HIOKI CLAMP ON HiTESTER Series
8 Páginas
-
HIOKI LR8400 Series MEMORY HiLOGGERs
12 Páginas
-
HIOKI POWER QUALITY ANALYZER PW3198
12 Páginas
-
HIOKI TEMPERATURE HiTESTER Series
4 Páginas
-
HIOKI 3151 EARTH HiTESTER
2 Páginas
-
HIOKI 3535 LCR HiTESTER
8 Páginas